Technical specifications: Range of operation 280-710 nm Diffraction grating (replica) 1250 strokes per millimeter The area of maximum energy concentration 350-450 nm The working order of the spectrum is the first The signal-to-noise ratio on the line is 632.8 nm when detuning from the center of the line by ± 3.3 nm is not worse than 3 * 106 times The slits are fiber optical fibers with a diameter of 200 microns, stacked in 1 row. The height of the slits is 5 mm The resolution of the monochromator with these slits is not worse than 0.34 nm The accuracy of the wavelength setting is not worse than 0.2 nm Dimensions are not more than 335 x 153 x 240 mm Weight is not more than 8 kg Supply voltage 187-242 V Power consumption not more than 12 watts Current frequency 49-51 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-5M"
Liquid analyzer "FLUORAT®-02-5M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, no more 0,005 Measurement range of the mass concentration of the control substance (phenol) in water, mg/dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ± 2 Warm-up time, min, no more than 30 Continuous operation time, h, at least 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, no more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, In × A, no more than 36 Time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-105M"
Capillary electrophoresis systems "KAPEL®-105M"
1 supp.
Technical specifications: The range of working detection wavelengths, nm from 190 to 380 Limits of permissible absolute error of setting the working wavelength, nm ± 5 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 220 Overall dimensions (LXC), mm, no more 420x570x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury monitor type RA-915AM for air analysis
Mercury monitor type RA-915AM for air analysis
1 supp.
Technical specifications: Ambient temperature, °C from +10 to +35 Relative humidity (at +25 °C), % no more than 98 Atmospheric pressure, kPa from 84 to 106.7 Power supply 220  22 V, 50  1 Hz Power consumption, VA no more than 150 Overall dimensions (LWC), mm Monitor Multiplexer 665x482x222 665x482x222 Weight, kg Monitor Multiplexer (2-16 channels) 25 15 - 25 Average time to failure, h 12000 Average service life, 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
2 supp.
from 218.11 ₽
Technical specifications: Ionization method Glow discharge plasma Discharge gas Air Time-of-flight Mass Analyzer with mesh-free ion mirror Resolution 4000 The number of simultaneously defined components is not limited Mass range 1-1000 m/z Detection limits 10-100 ppt Analysis time 1-3 min Vacuum system 1 Booster pump and 2 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Water hardness analyzer "AKMS-1"
Water hardness analyzer "AKMS-1"
1 supp.
Technical specifications: The range of detectable concentrations is 0.005-25.0 (5-25000) °F (mcgecv/L) The temperature of the analyzed flow is from + 5 to + 40 °C The pressure in the flow is 0.1-10 atm. Output of results Digital display of the device, portable display, RS485, RS232, current loop 4-20 mA (0-20) mA Display modes NORM, ALARM, LIMIT Version B4, P1, N1, according to GOST 12997-84 Category of climatic performance UHL4, according to GOST 15150-69 Ambient temperature from + 5 to + 50 °C Relative humidity at + 25 °C 80 % Atmospheric pressure 84-106.7 kPa The amplitude of external vibrations with a frequency of 10-55 Hz is not more than 0.15 mm Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption not more than 100 watts Dimensions 300x400x150 mm Weight not more than 20 kg The warranty period of operation is 1 year Average service life of at least 5 years Average time to failure of at least 20,000 hours
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Aluminum analyzer in water "FLUORATE® AA-2"
Aluminum analyzer in water "FLUORATE® AA-2"
1 supp.
Technical specifications: The range of detectable concentrations is 0.04-2 mg/l The temperature of the analyzed flow is from + 5 to + 50 °C The pressure in the flow is 0.1-10 atm. Number of measurements per hour 1-4 Output of results Digital scoreboard, RS485, RS232, 4-20 mA current loop Display modes NORM, ALARM, LIMIT Version B4, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Ambient temperature from + 5 to + 50 °C Relative humidity at + 25 °C 80% Atmospheric pressure 84-106.7 kPa The amplitude of external vibrations with a frequency of 10-55 Hz is not more than 0.15 mm Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption 100 W Dimensions 600x600x250 mm Weight Not more than 50 kg The warranty period of operation is 1 year Average service life of at least 5 years Average time to failure of at least 10,000 hours
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared analyzer "InfraLUM® FT-12" with a wake-up module
Infrared analyzer "InfraLUM® FT-12" with a wake-up module
1 supp.
Technical specifications: Measurement time, sec. 80 Standard sample volume in a cuvette, 500 ml Spectral range, cm-1 from 8700 to 13200 Spectral resolution, cm-1, not more than 10 The limit of the permissible value of the absolute error of the wavenumber scale, cm-1 ± 0.5 The level of positive and negative pseudo-scattered light caused by the nonlinearity of the photodetector system (relative to the maximum signal), %, not more than ± 0.25 Analyzer warm-up time, min, no more than 30 Continuous operation time of the analyzer, h, not less than 8 Overall dimensions, mm, not more than 530x485x495 Weight, kg, not more than 32 Power supply of analyzers from the AC network: AC power supply voltage, V frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, not more than 110 Average time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
1 supp.
Technical specifications: The power consumption of the alarm is not more than 150 watts The output electrical signal goes directly from the cable entry (B6), according to the standard scheme (4-20ma and (or) RS 485) Sample temperature is not more than 200 degrees C Sample pressure is not more than 1.5 Atm The pressure of the spent sample is not more than 0.5 Atm Cooling water temperature 5-30 Deg C Dimensions of the alarm (mm) 1200*600*400 The boundaries of the spectral range of optical radiation used for analysis, nm 240 - 380 Analysis time, from 1 Power supply - alternating voltage (220 ± 10%) V, (50± 2.5) Hz operating mode settings, min no more than 30 Display range , mg/l 0.01-30 The limit of the basic error for the trigger threshold (%) 20 The set threshold for triggering the alarm 0.1 – 30.9 in increments of 0.1 mg/l the probability of trouble-free operation during 5000 hours is not less than 0.95 average recovery time, no more than 2 hours average service life, at least 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M"
Mercury analyzer "RA-915M"
1 supp.
Technical specifications: Measuring range of mass concentration of mercury vapors in the air, ng/m3 from 20 to 20000 Limits of permissible basic relative error, d0, % ± 20 The limit of permissible relative standard deviation of the analyzer output signal, %5 The limit of the permissible value of the mean square deviation (SKO) of the zero signal, ng/m3 2 Drift of the zero signal of the analyzers in 5 minutes, ng/m3, no more than 2 The limit of permissible change of analyzer readings for 8 hours in fractions of d0 0.5 Time to establish the readings, s, no more than 20 Time of analyzer output to the mode, min, no more than 20 Volumetric flow rate of the analyzed air at the analyzer inlet, dm3/min, not less than 10 Volumetric air flow at the outlet of the gas analyzer system with the inlet blocked, dm3/min, not more than 0.3 Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 The limit of permissible additional error due to changes in ambient temperature within the operating range for every 10 ° C, in fractions of d0 0.5 The analyzers are powered by a built-in AC battery voltage (220 ±22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, not more than 7 Reliability indicators average time to failure, h, at least the full average life from the built-in AC battery voltage (220 ± 22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, no more than 7 Reliability indicators average time to failure, hours, at least full average service life, years, at least 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Monochromators "LM-3" and "LM-4"
Monochromators "LM-3" and "LM-4"
1 supp.
Technical specifications: LM-3 operating range 220-650 nm LM-4 operating range 220-900 nm Diffraction grating (replica) 1200 strokes per millimeter Radius of curvature DR 125 mm The area of maximum energy concentration is 300-400 nm Inverse linear dispersion in the specified spectral range of 6.7 nm/mm Relative opening 1:3.3 The slits are fiber optical fibers with a diameter of 200 microns, stacked in 1 row. The height of the slots is 5 mm The resolution of the monochromator with the specified slits in the ranges of 220-650 nm is not worse than 1.5 nm The resolution of the monochromator with the specified slits in the range of 650-900 nm is not worse than 2.5 nm The accuracy of the wavelength setting is not worse than 0.2 nm Dimensions no more than 205x125x150 mm Weight not more than 3 kg Supply voltage 90-120 / 187-242 V Power consumption not more than 12 W Current frequency 50/60 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Chromatographic columns for HPLC
Chromatographic columns for HPLC
1 supp.
Variants of execution: - silica gel with grafted octadecyl groups (C18, RP, ODS) - for the variant of reversed-phase HPLC (OF HPLC); - unmodified silica gel (SIL) – for normal-phase HPLC (NF HPLC).