Optical recorder of oil films "CRAB-1"
Optical recorder of oil films "CRAB-1"
1 supp.
Technical specifications: Sensitivity (minimum thickness of recorded oil films) from 0.5 microns The root-mean-square slope of the water surface up to 20 ° Distance from the receiving device up to 1000 m Sensor power supply 100-240 V, 50-60 Hz Power consumption up to 3 watts Ambient air temperature from -10 to +50 °C Humidity up to 100% (rain) Distance to the water surface 0.5–20 m Dimensions 120x180x120 mm Weight up to 1.5 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
EPR spectrometer CMS8400 NEO
EPR spectrometer CMS8400 NEO
The CMS8400 NEO is a compact electron paramagnetic resonance spectrometer designed for routine research in physics, chemistry, biology and related scientific fields for direct detection of free radicals and paramagnetic materials. The CMS8400 NEO can be used in both laboratory and industrial settings in the mode of on-line measurements, embedded in technological processes, thus providing control of parameters and reactions in the production process. Additional accessories and adapted software can make the spectrometer an analytical tool and allow to implement new complex applications in medicine, petrochemistry, brewing, sanitary and hygienic control, as well as in other industries.
Produced in: Belarus
Raid bomb BR-02T
Raid bomb BR-02T
It is designed to determine the absolute vapor pressure of crude oil and petroleum products with a saturated vapor pressure over 180 kPa (except for liquefied petroleum gases) in accordance with the State Standard 1756 and the State Standard 31874 (except for method B). The ratio of volumes of air and liquid chambers within 3.95 4.05.
Produced in: Tomsk
Sulfur Analyzer SPECTROSCAN IS, IS-T
Sulfur Analyzer SPECTROSCAN IS, IS-T
The IS-T and IS X-ray absorption flow SPECTROSCAN analyzers for sulfur in oil are designed to determine the mass fraction of sulfur in the flow of oil/petroleum products in the range from 0.02% to 6.00% (IS-T) or 0.04% to 6.0% (IS). Analyzers can be used for technological control during transportation and storage of oil, as well as during mixing (compounding) operations. The design of the analyzers allows them to be placed both independently and as part of a unit for measuring oil quality indicators (BIC) or a system for measuring the quantity and quality of oil (CIC). They are available in explosion-proof version. The analyzers have the function of automatically accounting for the influence of the density of the analyzed medium, as well as the content of water and chloride salts in it on the result of determining the mass fraction of sulfur. Structurally, the analyzers are a complete product of high factory readiness, having a block-modular design and including all the necessary functional devices to ensure efficient and safe operation.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
NEVA-412 alarm system
NEVA-412 alarm system
1 supp.
Technical specifications: Analog output 0-0.5 V (4-20 mA on request) Overall dimensions 320x255x175 mm Water pressure 0.1-3 atm The door of the alarm opens to the left side Measuring range 0-30 ppm Alarm relay contacts dry contact (power up to 2A/250V) Control relay contacts dry contact (power up to 2A/250V) Linearity +(-)2% in the range of 1-20 ppm Trigger threshold setting from 1 to 30 ppm (in increments of 1 ppm) Connecting dimensions of flanges external thread 1/2" Signal norm green LED Alarm red LED Degree of protection IP X4 The temperature of the controlled environment is +4 ... +55 °C Ambient temperature 0 ... +55 °C Measurement accuracy in accordance with resolution MERS.107(49) CF type flash memory card (software included) at least 32 MB RS485 digital output (on request) Power supply 200/240 V, 50/60 Hz (on request = 24 V) Weight not more than 10.5 kg Power consumption < 6 W
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Analyzer of petroleum products in water "FLUORATE® AE-2"
Analyzer of petroleum products in water "FLUORATE® AE-2"
1 supp.
Technical specifications: The range of detectable concentrations 0.025-1.0 and 0.1- 10 mg/l from 10 to 100 mg/l –can be used as an alarm The temperature of the analyzed flow is from + 4 to + 50 °C The pressure in the flow is 0.1-10 atm. Number of measurements per hour 1-4 Output of results Digital scoreboard, RS485, RS232, 4-20 mA current loop Display modes NORM, ALARM, LIMIT Version B1, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Ambient temperature from + 5 to + 50 °C Relative humidity at + 25 °C 80% Atmospheric pressure 84-106.7 kPa The amplitude of external vibrations with a frequency of 10-55 Hz is not more than 0.15 mm Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption not more than 100 watts Dimensions 600x600x250 mm Weight 50 kg The warranty period of operation is 1 year Average service life of at least 5 years Average time to failure of at least 20,000 hours
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Pressure gauge MTIf-160
Pressure gauge MTIf-160
Pressure gauge with a range of measured pressure 0...160 kPa. Accuracy class 0.4 Connection size M20x1.5 mm Overall dimensions 160 mm Weight 1.5 kg
Produced in: Tomsk
Chlorine and Sulfur Analyzer SPECTROSCAN CLSW
Chlorine and Sulfur Analyzer SPECTROSCAN CLSW
The device is developed on the basis of the analyzer SPECTROSCAN SW-D3, allows you to determine the mass fraction of organochlorine compounds in oil according to GOST R 52247-2004 (method B) and GOST 33342-2015 (method B), the sulfur content in automotive fuel, oil and liquid petroleum products in accordance with GOST R 52660-2006 / GOST ISO 20884-2016 and GOST R 53203-2008 / GOST 33194-2014, as well as to determine the mass fraction of chlorine and sulfur in any liquid samples in accordance with standardized techniques (methods). Implements arbitration methods for determining the mass fraction of organochlorine compounds in oil and the sulfur content in automobile fuel. The analyzer has successfully passed the interlaboratory tests under the guidance of JSC "VNII NP" (TK31). As a result of the tests, the accuracy of the method for determining the mass fraction of organochlorine compounds using the SPECTROSCAN CLSW analyzer was found to comply with the requirements of GOST R 52247-2004, method B, and the accuracy of the method was determined in the range of the mass fraction of organochlorine compounds from 1 ppm to 50 ppm. Determination of the mass fraction of organochlorine compounds in oil involves sampling of oil, distillation of naphtha fraction (204 ° C), washing of naphtha from hydrogen sulfide and inorganic chlorides. An internal standard is introduced into naphtha extracted from oil – a solution of bismuth in a non-polar solvent and an analysis is carried out. When determining the sulfur content, the analysis is carried out without additional sample preparation. The analyzer is a proprietary development of NPO "SPEKTRON". The device is manufactured in St. Petersburg mainly from domestic components. There is a conclusion of the Ministry of Industry and Trade on the production of products in the territory of the Russian Federation. The operator's actions when performing measurements are minimized: - the number/name of the sample is entered from the built-in keyboard; - the sample is poured into two cuvettes; - the obtained samples are placed in the analyzer and measurements are started. The analyzer performs all subsequent actions automatically without operator involvement: - calculates and displays the chlorine and/or sulfur content in the sample; - calculates convergence - the difference in determining the mass fraction of an element in the first and second samples; - prints measurement results on the built-in printer.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
1 supp.
Technical specifications: The power consumption of the alarm is not more than 150 watts The output electrical signal goes directly from the cable entry (B6), according to the standard scheme (4-20ma and (or) RS 485) Sample temperature is not more than 200 degrees C Sample pressure is not more than 1.5 Atm The pressure of the spent sample is not more than 0.5 Atm Cooling water temperature 5-30 Deg C Dimensions of the alarm (mm) 1200*600*400 The boundaries of the spectral range of optical radiation used for analysis, nm 240 - 380 Analysis time, from 1 Power supply - alternating voltage (220 ± 10%) V, (50± 2.5) Hz operating mode settings, min no more than 30 Display range , mg/l 0.01-30 The limit of the basic error for the trigger threshold (%) 20 The set threshold for triggering the alarm 0.1 – 30.9 in increments of 0.1 mg/l the probability of trouble-free operation during 5000 hours is not less than 0.95 average recovery time, no more than 2 hours average service life, at least 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Sulfur Analyzer SPECTROSCAN SE
Sulfur Analyzer SPECTROSCAN SE
The analyzer is designed to determine the mass fraction of sulfur from 3 million-1 (ppm) in oil and petroleum products in accordance with GOST R 51947-2002, GOST 32139-2019, GOST R EN ISO 20847-2010 / GOST ISO 20847-2014, ASTM D4294, GB/T 17040-2019. Implements an arbitration method for measuring the mass fraction of sulfur for oil, automotive fuels of class K2, K3, jet engine fuel, aviation gasoline, fuel oil and marine fuel, and is also used for operational control of sulfur content in automotive fuels of Class 4 and 5, gas oils, bitumen, lubricating oils and their components and other petroleum products. The analyzer greatly simplifies the routine analysis procedure. Intuitive interface provides convenience and ease of use. The analyzer is a proprietary development of NPO "SPEKTRON". The device is manufactured in St. Petersburg mainly from domestic components. Minimum operator actions: - calibration is selected and the name of the sample is entered; - two cuvettes are filled with a sample; - the obtained samples are placed in the analyzer and measurements are started; - all subsequent actions are performed automatically: - the average value of the mass fraction of sulfur is calculated and displayed; - repeatability is calculated; - the results are checked for compliance with the selected standard; - measurement results are printed on the built-in printer and saved.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Sulfur and Nitrogen Analyzer SPECTROSCAN META
Sulfur and Nitrogen Analyzer SPECTROSCAN META
The analyzer allows you to determine the content of sulfur and nitrogen in oil and petroleum products (diesel fuel, gasoline, kerosene, gas oil and any distillate petroleum products), hydrocarbon gas, liquefied petroleum gas (LPG), natural gas, liquefied natural gas (LNG), chemical synthesis products, biological materials by ultraviolet fluorescence and chemiluminescence. The analyzer is a proprietary development of NPO "SPEKTRON". The device is manufactured in St. Petersburg mainly from domestic components. There is a conclusion of the Ministry of Industry and Trade on the production of products in the territory of the Russian Federation. The analyzer is designed to determine: - mass fraction of sulfur in accordance with GOST ISO 20846-2016, GOST 34712-2021, GOST R 56866-2016, GOST 34237-2017, ASTM D5453-19, ASTM D6667-21, ASTM D7551-15, ISO 20729-17 ; - the mass fraction of nitrogen in accordance with ASTM D4629-17. A wide range of concentrations: from ultra-low to high. Modular principle: Each detector is a separate module. The device is equipped individually for each specific task. The possibility of simultaneous determination of sulfur and nitrogen in the analysis process. The principle of operation of the analyzer is to burn the test sample in an oxygen-enriched atmosphere or air at a temperature of 1050 ° C. The sulfur dioxide (SO2) and nitrogen oxide (NO) formed during combustion are transferred by carrier gas to the detection units with preliminary removal of water vapor, on the desiccant, and soot, on the filter. Determination of sulfur is carried out by ultraviolet fluorescence. Determination of nitrogen by chemiluminescence.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Pressure gauge MTIf-100
Pressure gauge MTIf-100
Pressure gauge with a range of measured pressure 0 ... 100 kPa. Accuracy class 0.4 Connection size M20x1.5 mm Overall dimensions 160 mm
Produced in: Tomsk