Lumeks

Lumeks

39 products
View:
Telephone number:
Website: www.lumex.ru
Address:
Russia, Saint Petersburg, 1, letter B
Website: www.lumex.ru
Address:
Russia, Saint Petersburg, 1, letter B
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 9
    Applying
  • 11
    Names
  • 1
    Manufacturer
  • 1
    Made in
  • 11
    Additional
View:
37 products
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
1 supp.
Technical specifications: The power consumption of the alarm is not more than 150 watts The output electrical signal goes directly from the cable entry (B6), according to the standard scheme (4-20ma and (or) RS 485) Sample temperature is not more than 200 degrees C Sample pressure is not more than 1.5 Atm The pressure of the spent sample is not more than 0.5 Atm Cooling water temperature 5-30 Deg C Dimensions of the alarm (mm) 1200*600*400 The boundaries of the spectral range of optical radiation used for analysis, nm 240 - 380 Analysis time, from 1 Power supply - alternating voltage (220 ± 10%) V, (50± 2.5) Hz operating mode settings, min no more than 30 Display range , mg/l 0.01-30 The limit of the basic error for the trigger threshold (%) 20 The set threshold for triggering the alarm 0.1 – 30.9 in increments of 0.1 mg/l the probability of trouble-free operation during 5000 hours is not less than 0.95 average recovery time, no more than 2 hours average service life, at least 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Chromatographic columns for HPLC
Chromatographic columns for HPLC
1 supp.
Variants of execution: - silica gel with grafted octadecyl groups (C18, RP, ODS) - for the variant of reversed-phase HPLC (OF HPLC); - unmodified silica gel (SIL) – for normal-phase HPLC (NF HPLC).
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Water hardness analyzer "AKMS-1"
Water hardness analyzer "AKMS-1"
1 supp.
Technical specifications: The range of detectable concentrations is 0.005-25.0 (5-25000) °F (mcgecv/L) The temperature of the analyzed flow is from + 5 to + 40 °C The pressure in the flow is 0.1-10 atm. Output of results Digital display of the device, portable display, RS485, RS232, current loop 4-20 mA (0-20) mA Display modes NORM, ALARM, LIMIT Version B4, P1, N1, according to GOST 12997-84 Category of climatic performance UHL4, according to GOST 15150-69 Ambient temperature from + 5 to + 50 °C Relative humidity at + 25 °C 80 % Atmospheric pressure 84-106.7 kPa The amplitude of external vibrations with a frequency of 10-55 Hz is not more than 0.15 mm Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption not more than 100 watts Dimensions 300x400x150 mm Weight not more than 20 kg The warranty period of operation is 1 year Average service life of at least 5 years Average time to failure of at least 20,000 hours
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury Monitor type RA-915AM for Natural Gas Analysis
Mercury Monitor type RA-915AM for Natural Gas Analysis
1 supp.
Technical specifications: Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 Volume flow rate of the analyzed gas at the monitor inlet, dm3/min, not less than 4 Monitor power supply from AC mains: voltage, V frequency, Hz 220 ± 22 50 ± 1 Power consumption, In × A, not more than 150 Overall dimensions (LXC), mm, no more 665x482x222 Weight, kg, not more than 25 Operating conditions: - ambient temperature, °C from 10 to 35 - relative humidity (at 25 °C), %, not more than 80 - atmospheric pressure, kPa from 84 to 106.7 - relative humidity of the analyzed gas (at 20 °C), %, not more than 99 Average time to failure, h 12000 Average service life, 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury content indicator "SR-1"
Mercury content indicator "SR-1"
1 supp.
Technical specifications: The minimum limit of operation is 3×10-4 mg/m3 (the average daily MPC of a residential premises in accordance with GN 2.1.6.1338-03 of May 21, 2003) The range of set thresholds is from 3×10-4 mg/m3 to 1×10-3 mg/m3 Measurement time, no more than 15 s Output signals ON, READY, DANGEROUS, FAULTY Electrical parameters of the output signal 0-24 V, 0.5 A Operating mode Monitoring Average full service life of 5 years Frequency of maintenance 1 time in 3 months RS-232 digital output Power supply 190-240 V, 50 Hz Power consumption, no more than 30 watts Overall dimensions, no more than 280x420x600 mm Weight, not more than 18 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mass spectrometer for the analysis of liquid samples "Lumas LIQUID"
Mass spectrometer for the analysis of liquid samples "Lumas LIQUID"
1 supp.
Technical specifications: ESI / APCI ionization method Time-of-Flight Mass Analyzer The maximum repetition frequency of the ejection pulses is 10 kHz Recording speed of spectra Up to 100 spectra per second Characteristics of a 12-bit ADC, 2 GHz The number of simultaneously defined components is unlimited Mass range 1-2000 m/z Resolution > 4000 Vacuum system of 2 Fornaps and 3 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with the prefix "URP"
Mercury analyzer "RA-915M" with the prefix "URP"
1 supp.
Technical specifications: Continuous operation time 8 hours The dimensions of the analyzer are 470x220x110 mm The dimensions of the console are 340x240x120 mm Analyzer weight 7.5 kg The weight of the console is 5.5 kg Power supply 220 V Supply voltage of RA-915M: (220 ±22) V, 50 Hz URP supply voltage: (220±22) V, 50 Hz Power consumption of RA-915M: 35 VA URP power consumption: 220 VA Current frequency 50 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Aluminum analyzer in water "FLUORATE® AA-2"
Aluminum analyzer in water "FLUORATE® AA-2"
1 supp.
Technical specifications: The range of detectable concentrations is 0.04-2 mg/l The temperature of the analyzed flow is from + 5 to + 50 °C The pressure in the flow is 0.1-10 atm. Number of measurements per hour 1-4 Output of results Digital scoreboard, RS485, RS232, 4-20 mA current loop Display modes NORM, ALARM, LIMIT Version B4, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Ambient temperature from + 5 to + 50 °C Relative humidity at + 25 °C 80% Atmospheric pressure 84-106.7 kPa The amplitude of external vibrations with a frequency of 10-55 Hz is not more than 0.15 mm Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption 100 W Dimensions 600x600x250 mm Weight Not more than 50 kg The warranty period of operation is 1 year Average service life of at least 5 years Average time to failure of at least 10,000 hours
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with the prefix "RP-92"
Mercury analyzer "RA-915M" with the prefix "RP-92"
1 supp.
Technical specifications: Continuous operation time 8 hours Analyzer dimensions (LxWxH), mm, no more than 470x110x220 mm Overall dimensions of the pumping unit: (LxWxH), mm, no more than 360x110x125 mm Analyzer weight 7 kg The weight of the console is 7 kg Power supply 100 - 240 V Powered by an autonomous RA source-915+ - 6/14 In Powered by an autonomous source RP-91 - 12 V Power consumption 20 W Current frequency 50/60 Hz The mass of the pumping unit is 3 kg Average service life, years, at least 5 Volume of the injected sample, cm3 0.5 - 10.0 Air flow, dm3/min 0.8 - 4.2
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mass spectrometer for the analysis of solid-phase samples "Lumas SOLID"
Mass spectrometer for the analysis of solid-phase samples "Lumas SOLID"
1 supp.
Technical specifications: Method of ionization Plasma pulsed glow discharge Discharge gas Argon, consumption less than 1 l/hour Time-of-flight Mass Analyzer with mesh-free ion mirror Resolution 4000 The number of simultaneously defined components is unlimited Mass range 1-1000 m/z Detection limits 1-100 ppb Layer-by-layer resolution Up to 5 nm Depth of analysis Up to 30 microns The time for one analysis of a solid sample is 30 minutes (with the option of a revolver system – 3-5 minutes) Vacuum system 1 Booster pump and 2 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Monochromator "MHD-2"
Monochromator "MHD-2"
1 supp.
Technical specifications: Range of operation 280-710 nm Diffraction grating (replica) 1250 strokes per millimeter The area of maximum energy concentration 350-450 nm The working order of the spectrum is the first The signal-to-noise ratio on the line is 632.8 nm when detuning from the center of the line by ± 3.3 nm is not worse than 3 * 106 times The slits are fiber optical fibers with a diameter of 200 microns, stacked in 1 row. The height of the slits is 5 mm The resolution of the monochromator with these slits is not worse than 0.34 nm The accuracy of the wavelength setting is not worse than 0.2 nm Dimensions are not more than 335 x 153 x 240 mm Weight is not more than 8 kg Supply voltage 187-242 V Power consumption not more than 12 watts Current frequency 49-51 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M"
Mercury analyzer "RA-915M"
1 supp.
Technical specifications: Measuring range of mass concentration of mercury vapors in the air, ng/m3 from 20 to 20000 Limits of permissible basic relative error, d0, % ± 20 The limit of permissible relative standard deviation of the analyzer output signal, %5 The limit of the permissible value of the mean square deviation (SKO) of the zero signal, ng/m3 2 Drift of the zero signal of the analyzers in 5 minutes, ng/m3, no more than 2 The limit of permissible change of analyzer readings for 8 hours in fractions of d0 0.5 Time to establish the readings, s, no more than 20 Time of analyzer output to the mode, min, no more than 20 Volumetric flow rate of the analyzed air at the analyzer inlet, dm3/min, not less than 10 Volumetric air flow at the outlet of the gas analyzer system with the inlet blocked, dm3/min, not more than 0.3 Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 The limit of permissible additional error due to changes in ambient temperature within the operating range for every 10 ° C, in fractions of d0 0.5 The analyzers are powered by a built-in AC battery voltage (220 ±22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, not more than 7 Reliability indicators average time to failure, h, at least the full average life from the built-in AC battery voltage (220 ± 22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, no more than 7 Reliability indicators average time to failure, hours, at least full average service life, years, at least 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg