Universal biochemical analyzer "FLUORAT®-02-ABLF-T"
Universal biochemical analyzer "FLUORAT®-02-ABLF-T"
1 supp.
Technical characteristics: Consumption of working reagents 1.0–2.0 ml – for standard filling cuvette K10 from 400 ml – for photometric techniques Filters for photometer mode, nm built-in interference filters 340, 405, 505 ,545, 575, 630 spectral half-width of 10 nm Filters for fluorimeter and chemiluminometer modes on request, in the spectral range of 270-850 nm Chemiluminescence channel sensitivity 10000 photons per second Optical density measurement range, E.O.P. 0-2.20 Photometric channel accuracy, %2 Memory of 100 measurement programs Temperature control of the measuring cell (for photometer and chemiluminometer modes) built-in thermostat on the Peltier element: 25, 30, 37 OC; accuracy ± 0.2 oC Volume of the flow cuvette, mkl 80 Pump type (only for photometer mode) peristaltic pump with programmable liquid supply volume Productivity, analyses/hour up to 100 (by the endpoint method) Information output liquid crystal display and personal computer Power supply, 220 ± 22 Dimensions, mm 430x350x160 Weight, kg 10
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Measuring and diagnostic complex PKSOD-M
Measuring and diagnostic complex PKSOD-M
The proposed measuring and diagnostic complex is designed to: - provide monitoring of the technical condition of electric drive valves of nuclear power plants; – detection and identification of malfunctions of components and equipment of electric drive valves at an early stage of their occurrence; – issuance of measurement results and diagnostics of electric drive valves to the operational personnel of the station.
Produced in: Rostov-on-Don
Laboratory mercury analyzer "RA-915Lab"
Laboratory mercury analyzer "RA-915Lab"
1 supp.
Technical specifications: Measuring range 0.5–500 ng Sample dispenser capacity 5000 mg / 2800 ml Analysis time 1-5 min Operating temperature range with software control 50-950 °C with software control The capacity of the autosampler is 45 samples Power supply 220 ± 22 V, 50 ± 1 Hz Dimensions (LxWxH), no more: with autosampler without autosampler 450x840x460 mm 450x490x460 mm Weight, no more: with autosampler without autosampler 57 kg 40 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
1 supp.
Technical specifications: The upper limit of the measurement range is 5 mg/kg Analysis time 1-5 min Permissible sample weights are 10-500 mg The weight of the console is 17 kg Air pumping speed 1-3 l/min Dimensions and weight of the analyzer 470x210x110 mm; 7.5 kg Power supply of the PIRO-915+ 220 V, 700 W Analyzer power supply 220 V, 15 W Dimensions of the power supply and pumping unit no more than 400x280x135 mm The dimensions of the thermal camera unit and the remote optical unit are no more than 430x340x135 mm The upper limit of the measurement range for sample weighting is 20 mg 200 mg/kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Aluminum analyzer in water "FLUORATE® AA-2"
Aluminum analyzer in water "FLUORATE® AA-2"
1 supp.
Technical specifications: The range of detectable concentrations is 0.04-2 mg/l The temperature of the analyzed flow is from + 5 to + 50 °C The pressure in the flow is 0.1-10 atm. Number of measurements per hour 1-4 Output of results Digital scoreboard, RS485, RS232, 4-20 mA current loop Display modes NORM, ALARM, LIMIT Version B4, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Ambient temperature from + 5 to + 50 °C Relative humidity at + 25 °C 80% Atmospheric pressure 84-106.7 kPa The amplitude of external vibrations with a frequency of 10-55 Hz is not more than 0.15 mm Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption 100 W Dimensions 600x600x250 mm Weight Not more than 50 kg The warranty period of operation is 1 year Average service life of at least 5 years Average time to failure of at least 10,000 hours
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Analyzer of sodium hypochlorite in water "AGH-3"
Analyzer of sodium hypochlorite in water "AGH-3"
1 supp.
Technical specifications: Output of results to digital display board, RS485, RS232; current loop 4-20 mA (0-20) mA The pressure in the flow is 0.1-10 atm. The range of detectable concentrations is 20-200 g/l Version B4, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Relative humidity at + 25 °C 80 % Display modes NORM, ALARM, LIMIT The temperature of the analyzed flow is from +0.5 to +25 °C Ambient temperature from +5 to +35 °C Atmospheric pressure 87-107 kPa The warranty period of operation is 1 year Average service life of at least 3 years Dimensions - electronic block - optical unit no more than 300x400x150 mm no more than 120x90x90 mm Weight - electronic block - optical unit no more than 10 kg not more than 2 kg Power supply 187-242 V, 50 ± 1 Hz, from an autonomous source, 12V Power consumption 100 W
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Analyzer of petroleum products in water "FLUORATE® AE-2"
Analyzer of petroleum products in water "FLUORATE® AE-2"
1 supp.
Technical specifications: The range of detectable concentrations 0.025-1.0 and 0.1- 10 mg/l from 10 to 100 mg/l –can be used as an alarm The temperature of the analyzed flow is from + 4 to + 50 °C The pressure in the flow is 0.1-10 atm. Number of measurements per hour 1-4 Output of results Digital scoreboard, RS485, RS232, 4-20 mA current loop Display modes NORM, ALARM, LIMIT Version B1, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Ambient temperature from + 5 to + 50 °C Relative humidity at + 25 °C 80% Atmospheric pressure 84-106.7 kPa The amplitude of external vibrations with a frequency of 10-55 Hz is not more than 0.15 mm Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption not more than 100 watts Dimensions 600x600x250 mm Weight 50 kg The warranty period of operation is 1 year Average service life of at least 5 years Average time to failure of at least 20,000 hours
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
MARK-5010 Hydrogen Purity Analyzer
MARK-5010 Hydrogen Purity Analyzer
High-precision measurements of hydrogen concentration in the range of 95-100% Monitoring of the operation of electrolyzers, control of hydrogen purity in the processes of hydrogen cooling of generators, in the technological processes of chemical, petrochemical, metallurgical and other industries 24 months warranty for deliveries across the Russian Federation A new patented measurement method The device does not require calibration Selectivity of measurement Direct method of measuring molecular hydrogen Insensitivity to humidity, carbon dioxide, oil vapor Measurement time 3-5 min Simple, intuitive interface Minimum maintenance Self-diagnosis Routine maintenance no more than 1 time per year Long-lasting, highly stable sensor The service life of the sensor is at least 10 years Color touch screen
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod, Moscow
Quattroplex Lab multiplex analyzer, 1 х 96-well plate, with peripheral devices
Quattroplex Lab multiplex analyzer, 1 х 96-well plate, with peripheral devices
1 supp.
QuattroPlex is the first Russian open multiplex platform for quantitative and qualitative analysis of biomarkers using immunofluorescence analysis on fluorescent beads. The detection technology copies xMap technology, which allows the analysis of several dozen analytes in a minimum volume. The device allows you to analyze a wide range of markers and is designed to work with 96-well plates.
Advantages of QuattroPlex Lab:
  • Multiplexity - diagnostics of up to 50 markers in one sample in one analysis;
  • analysis of a wide range of markers (rheumatology, autoimmune diseases, HLA, cytokines, infections);
  • open system - use of any test systems based on magnetic beads;
  • high sensitivity - the ability to conduct qualitative and quantitative analysis;
  • design that requires minimal space on the desktop;
  • possibility of using a 96-well plate for protocol scaling.

Technical characteristics of QuattroPlex Lab:
  • Detected bead size, microns - from 0.5 to 100;
  • 3 fluorescence detection channels;
  • fluorescence excitation wavelengths, nm - from 380 to 850;
  • fluorescence detection wavelengths, nm - from 450 to 950;
  • detector - CMOS matrix;
  • sample volume, µl - from 100;
  • number of samples studied - 96 (96-well plate);
  • the ability to load several 96-well plates in one experiment;
  • time to analyze one sample, sec - 40;
  • Software for managing and analyzing results - QuattroPlex software for processing and analyzing results, compatible with Win/Linux;
  • interfaces for connecting to a laptop/PC - Internet/Wi-Fi;
  • dimensions W×D×H, cm - 20×30×60.

Delivery set:
  • QuattroPlex multiplex biomarker analysis system;
  • starter kit of consumables;
  • computer, keyboard, mouse and monitor.
Aivok
Zelenograd
Produced in: Zelenograd