Thermoreactor laboratory "TERMION"
Thermoreactor laboratory "TERMION"
1 supp.
Technical specifications: Operating temperature range, °C 50 ... 175 The discreteness of the temperature setting, °C 0.1 Temperature setting accuracy, °C ± 2 Accuracy of temperature maintenance, °C ± 0.5 Time interval setting range from 1 min to 20 h 59 min Time setting discreteness, min 1 Power consumption, V * A, no more than 450 The size of the landing nest (diameter x depth), mm 17 x 72 Number of landing nests, pcs 29 Overall dimensions, mm, not more than 300 x 300 x 120 Weight, kg, not more than 8
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Atomic absorption spectrometer "MGA-1000"
Atomic absorption spectrometer "MGA-1000"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 900 Spectral resolution, nm, no more: - in the range from 190 to 600 nm inclusive - in the range over 600 to 900 nm inclusive 2 3 Limit of detection of manganese, pg, no more than 3 Nickel detection limit, pg, no more than 20 The time of setting the operating mode of the spectrometers, min, no more than 15 The time of continuous operation of the spectrometers, h, no less than 8 The spectrometers are powered by a three-phase alternating current network: - rated supply voltage, V - frequency, Hz 380 (50 ±1) Overall dimensions of the spectrometer, mm, no more than 800 x 475 x 310 Mass of the spectrometer, kg, no more than 50 Power consumed by spectrometers, kV * A, no more: - in standby modes and settings of analytical parameters - in atomization and purification modes 0.1 6 Average time to failure, h, not less than 4000
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid chromatograph "LUMACHROM®"
Liquid chromatograph "LUMACHROM®"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 360 Limits of permissible absolute error of wavelength setting, nm ± 5 Detection limit of anthracene (wavelength 252 nm), ng/cm3, no more than 1 The limit of the permissible value of the relative mean square deviation of the output signal (n =5), % of the retention time over the peak area of 1.5 2 Limits of the permissible value of the relative change in the output signal (peak area) for 4 hours of continuous operation, % ± 5 Overall dimensions (LxWxH), mm, no more: 270x420x190 Weight, kg, not more than 9.5 Power consumption, V· A, not more than 50
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-5M"
Liquid analyzer "FLUORAT®-02-5M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, no more 0,005 Measurement range of the mass concentration of the control substance (phenol) in water, mg/dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ± 2 Warm-up time, min, no more than 30 Continuous operation time, h, at least 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, no more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, In × A, no more than 36 Time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Sample preparation system – microwave mineralizer "MINOTAUR®-2"
Sample preparation system – microwave mineralizer "MINOTAUR®-2"
1 supp.
Technical specifications: Frequency of the generated magnetron radiation, MHz 2450 ±50 Number of simultaneously decomposed samples 1 The maximum volume of the processed sample, cm3 50 Maximum working pressure in the container, atm 9 Power consumption, V*A 600 The average absorbed power (W) in the reactor when heating 30 cm3 of distilled water at 100% output power level of the magnetron in the range of supply voltage from 187 to 242 V 150... 250 Average time to failure, h, not less than 2500 Average service life, years, at least 5 Overall dimensions, mm, no more than 500x450x150 Weight, kg, no more than 22
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mass spectrometer for the analysis of solid-phase samples "Lumas SOLID"
Mass spectrometer for the analysis of solid-phase samples "Lumas SOLID"
1 supp.
Technical specifications: Method of ionization Plasma pulsed glow discharge Discharge gas Argon, consumption less than 1 l/hour Time-of-flight Mass Analyzer with mesh-free ion mirror Resolution 4000 The number of simultaneously defined components is unlimited Mass range 1-1000 m/z Detection limits 1-100 ppb Layer-by-layer resolution Up to 5 nm Depth of analysis Up to 30 microns The time for one analysis of a solid sample is 30 minutes (with the option of a revolver system – 3-5 minutes) Vacuum system 1 Booster pump and 2 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-4M"
Liquid analyzer "FLUORAT®-02-4M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, not more than 0.005 Measurement range of the mass concentration of the control substance (phenol) in water, mg / dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ±2 Warm-up time, min, not more than 30 Continuous operation time, h, not less than 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, not more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, no more than 36 Operating time for failure, h, no less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Laboratory mercury analyzer "RA-915Lab"
Laboratory mercury analyzer "RA-915Lab"
1 supp.
Technical specifications: Measuring range 0.5–500 ng Sample dispenser capacity 5000 mg / 2800 ml Analysis time 1-5 min Operating temperature range with software control 50-950 °C with software control The capacity of the autosampler is 45 samples Power supply 220 ± 22 V, 50 ± 1 Hz Dimensions (LxWxH), no more: with autosampler without autosampler 450x840x460 mm 450x490x460 mm Weight, no more: with autosampler without autosampler 57 kg 40 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared analyzer "InfraLUM® FT-12"
Infrared analyzer "InfraLUM® FT-12"
1 supp.
Technical specifications: Measurement time, 80 seconds Standard sample volume in a cuvette, 50 ml Spectral range, cm-1 from 8700 to 13200 Spectral resolution, cm-1, no more than 10 The limit of the permissible value of the absolute error of the wave number scale, cm-1 ±0,5 Analyzer warm-up time, min, no more than 30 Continuous operation time of the analyzer, h, at least 8 Overall dimensions, mm, no more than 530x450x380 Weight, kg, not more than 32 Power supply of analyzers from the AC network: AC power supply voltage, V frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, not more than 110 Average time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Chromatographic columns for HPLC
Chromatographic columns for HPLC
1 supp.
Variants of execution: - silica gel with grafted octadecyl groups (C18, RP, ODS) - for the variant of reversed-phase HPLC (OF HPLC); - unmodified silica gel (SIL) – for normal-phase HPLC (NF HPLC).
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-104T"
Capillary electrophoresis systems "KAPEL®-104T"
1 supp.
Technical specifications: The working wavelength of detection, nm 254 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 150 Overall dimensions (LXC), mm, no more 420x460x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
1 supp.
Technical specifications: The upper limit of the measurement range is 5 mg/kg Analysis time 1-5 min Permissible sample weights are 10-500 mg The weight of the console is 17 kg Air pumping speed 1-3 l/min Dimensions and weight of the analyzer 470x210x110 mm; 7.5 kg Power supply of the PIRO-915+ 220 V, 700 W Analyzer power supply 220 V, 15 W Dimensions of the power supply and pumping unit no more than 400x280x135 mm The dimensions of the thermal camera unit and the remote optical unit are no more than 430x340x135 mm The upper limit of the measurement range for sample weighting is 20 mg 200 mg/kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg