Equipment

2244 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 388
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2244 products
Contact thermometer TK-5.01PTS
Contact thermometer TK-5.01PTS
from 16 560 ₽
The digital contact thermometer TK-5.01PTS is designed to measure the temperature of the surface of solids by direct contact of the probe with the measuring object. The digital contact thermometer consists of an electronic unit and a non-replaceable surface probe. Thermoelectric converters (TP) with NSH according to GOST R 8.585 are used as a thermosensitive element in the probe.
Produced in: Moscow
Explosion-proof drying cabinet SNOL-90
Explosion-proof drying cabinet SNOL-90
from 447 168 ₽
Explosion-proof drying cabinet SNOL-90 is designed for drying, tempering, aging, thermal testing and other types of heat treatment of various materials in an air environment at temperatures up to 240 ° C with natural or forced air convection in stationary conditions. The environment is a potentially explosive mixture of air and gases, vapors, mists of categories IIA and IIB.
Produced in: Tula
Acousto-optic video spectrometer
Acousto-optic video spectrometer
At the Scientific Research Center of the Russian Academy of Sciences, the technology of acousto-optic filtration of optical radiation is used to create a wide class of optical devices that are successfully used, for example, in biomedicine to diagnose various diseases (including oncology), in agriculture to diagnose the condition of plants, during non-destructive testing of complex technical objects and in solving other tasks. Acousto-optics has a number of important advantages over other technologies for obtaining spectral information: - the ability to create imaging devices without spatial scanning, since the acousto-optic filter is a software-controlled tunable light filter; - the compact modular design allows the acousto-optic filter to be integrated into the optical circuit of most imaging devices, which expands their analytical capabilities; - spectrum scanning is carried out by means of an electrical signal, without mechanical scanning; - fast arbitrary spectral addressing causes high shooting speed and the absence of redundant information; - software management. The key element of the presented device – an acousto–optic filter - is being developed at the Scientific Research Center of the UP RAS on the basis of original calculation methods. The manufacture of acousto-optic filters, optical and mechanical components, as well as the assembly, tuning, and calibration of such devices is also carried out at the Scientific Research Center of the UP RAS.
STC UP RAS
Москва
Produced in: Moscow
ND-1000 High vacuum diffusion pump
ND-1000 High vacuum diffusion pump
The working condition of the ND-1000 diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. The working fluid is "VACMA OIL 500" vacuum oil (under technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-1000 diffusion pump is a maximum of 23 liters, a minimum of 16 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change. The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of heaters in the ND-1000 diffusion pump using two temperature sensors. The temperature sensor must be installed in a special radiator socket above the heater. In the event that there is a loss of working fluid and an increase in the temperature of the radiators to 360 0C for the ND-1000 diffusion pump, the temperature sensor must give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be performed only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4°C to plus 25°C. The recommended cooling water consumption for the housing is 1500 l/h, for the oil reflector 150 l / h and is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break).
Produced in: Kazan
PLKS-02 Heating plate
PLKS-02 Heating plate
Laboratory heating plate with two heating sections and with the possibility of setting the temperature and heating time. The heating platforms are made of glass-ceramic. The size of the total heating surface: 440x284 mm. Heating temperature: 40-500 oC.
Produced in: Tomsk
Universal energy dispersive X-ray fluorescence spectrometer BRA-135F
Universal energy dispersive X-ray fluorescence spectrometer BRA-135F
The XRF analyzer BRA-135F is an energy dispersive spectrometer which can simultaneously determine the presence of up to twenty chemical elements - from 9F to 92U - in the analyzed sample. Samples can be in liquid, solid, powdered or deposited on a substrate. The analyzer captures concentrations from tenths of mg/kg. The model BRA-135F performs quantitative/semi-quantitative spectral analysis of steel and alloys. It also performs spectral analysis of oil, petroleum and other petroleum products, detecting in their composition even the smallest concentrations of impurities of various metals. The vacuum sample chamber and ultra-slim detector inlet provides a low detection limit in the range of light elements from 9F to 17Cl. The high-performance silicon drift detector (SDD) with an energy resolution of less than 135eV allows the separation of spectral lines of almost all elements, which makes the analysis of complex multicomponent substances (high-alloy steels, precision alloys, polymetallic ores, etc.) possible.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
UCHX2-78
UCHX2-78
Basic properties: Wide frequency range; Sufficiently large output power; High level of suppression of side harmonics of the input signal; Low phase noise value; Relatively simple technical solutions: - synchronization and frequency stabilization, - stabilization and adjustment of the output power level, - implementation of amplitude and frequency modulation modes; Do not require external bias diodes. Operating conditions: Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical characteristics Input/output frequency range, GHz 26,78-39,17 / 53,57-78,33 Losses (max.), dB 15 Input power level, dBm 15-21 Unevenness of output power (Rvh. = 20 dBm), dB ± 2.0 The level of parasitic harmonics of the input signal at the output (min.), dBn 20 Output VSWR (max.) 2.0 Connector type: • Input Coax. 2.4/1.0 mm (plug/socket) • Output Waveguide 3,759x1,88 mm (50-75GGo) Overall dimensions, mm 26x20x20 Weight, g 50
Produced in: Moscow
Trace Searcher Success AG-308.60N
Trace Searcher Success AG-308.60N
from 205 800 ₽
A trace searching kit for finding underground utilities (cable lines, metal pipelines, and other communications made of conductive materials). The kit includes a receiver in the form of a monoblock with LED indication, as well as a generator with increased power up to 180 watts and a range of up to 5 km. Connection to the desired route is possible both by contact and contactless method.
Produced in: Kolomna, Moscow region
pH meter MARK® 903
pH meter MARK® 903
Measurement of the activity of hydrogen ions (pH, pH25), ORP, EMF and temperature of aqueous media. Operational control of parameters of water-chemical regimes at thermal and nuclear power facilities, in accordance with CO 153-34.37.303. Convenience and accuracy of measurement | Automatic temperature compensation. Automatic recognition of buffer solutions. Measurement modes | pH or pH25 and temperature. EMF and temperature. pH measurement in flow and immersion modes | The flow-filling module MPN 901/903 is included. Self-diagnosis | Non-volatile electronic notebook | The ability to record up to 500 measurement groups in User-named folders. USB port, software included | The ability to create and manage a data archive on a PC. Graphic indicator with backlight | Indication of readings in a user-friendly format. Ease of settings. IP65 | Compact sealed device is reliably protected from dust and moisture. Low power consumption | Up to 600 hours of continuous operation from a set of AA elements.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
 Magnetometer - Measuring Residual Magnetization ION-3701 Conveyor
Magnetometer - Measuring Residual Magnetization ION-3701 Conveyor
It is a modern high-precision device (a variant of the ION-3701 device) and used for a wide range of tasks in areas where it is necessary to determine the magnitude of the magnetic field and residual magnetization in shop conditions, on the conveyor, during acceptance and inspection of parts and workpieces. It is equipped with a three-dimensional magnetic field sensor and has outstanding technical characteristics and extensive functionality.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Muffle furnace LF-9/11-G1
Muffle furnace LF-9/11-G1
Design features: Durable ceramic muffle; Closed heaters on four sides of the chamber; Microprocessor temperature controller; Conveniently located control panel and bright LED display; Ease of management and control; LED indicators of heater operation and protection operation; Automatic shutdown of heating when opening the door; The door opens up and faces the user with the cold side; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1100 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x150x290 mm Overall dimensions, WxHxD, not more than 525x625x620 mm Rated supply voltage, 220 V Rated power, W 5500
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum drying cabinet with automatic control SNVS-210/5
Vacuum drying cabinet with automatic control SNVS-210/5
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with an appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing devices under low pressure conditions under various temperature conditions.
Produced in: Tula