NV-1500 SHV-B-NERZH Fume cupboard with stainless steel countertop
NV-1500 SHV-B-NERZH Fume cupboard with stainless steel countertop
from 81 338 ₽
The Korsa NV-1500 SHV-NERZH Laboratory fume cupboards are single—frame cabinets with a width of 1410 mm with a stainless steel countertop. External dimensions of the cabinet (W×D×H): 1410×700×1960 mm. Dimensions of the working area (W×D×H): 1378×540×750 mm. Table top: stainless steel. Convenient fume cupboards for comfortable work in the laboratory Working surface material: stainless steel. It is well suited for biological or medical laboratories, but it is not recommended for use in chemical laboratories. It is resistant to prolonged exposure to temperature, organic solvents, and oils. It has limited resistance to short-term exposure to concentrated mineral acids and alkalis and is destroyed by prolonged exposure to concentrated acids. The working area is closed by a single lifting frame with a counterweight. It has two exhaust zones: the hood of the exhaust box and the level of the countertop. Diameter of the flange for connection to the ventilation system: 150 mm. Working area size (W×D×H): 1378×540×750 mm. Please note that the cabinet narrows upwards. At a height of 50 cm, the depth of the working area will be 410 mm, at a height of 70 cm: 365 mm. If you need to place high equipment, then make sure that it corresponds to the dimensions of the camera, otherwise you will not be able to close the cabinet. The height of the raised glass above the cabinet: 510 mm, that is, with the glass raised, the total height of the cabinet will be 2470 mm. The working area is illuminated by an LED lamp (included in the package). The switch is located on the right-hand side of the cabinet, next to the sockets. The fume cupboard is equipped with two sockets, one of them with grounding. Sockets have the IP20 degree of protection, maximum load: 1.5 kW. The base of the cabinet is an all-welded metal frame in powder coating. The side laminated panels (chipboard with a thickness of 16 mm) are edged with a durable PVC edge with a thickness of 2 mm, which increases their impact resistance and mechanical strength. The cabinet legs are adjustable in height within two centimeters, allowing you to place the cabinet even on a rather uneven floor.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Verification module PM-10
Verification module PM-10
The composition of the PM-10 verification module: Wattmeter of passing power M2-35; Complex transmission and reflection coefficients meter "OBZOR-804/1"; Universal voltmeter V7-81 (2 pcs.); High-frequency signal generator G4-229; High-frequency signal generator G4-230; DC power supply B5-79/1 (2 pcs.); AC power source B2-7 (2 pcs.); The measure of DC electrical resistance is multi-valued MS3070-3, CT 0.005; The measure of DC electrical resistance is multi-valued MS3055, CT 0.02; Single-digit electrical resistance measures MS3080 (0.1; 1 ohm, CT 0.005); Thermoelectric voltage converter 0.5 V; Kit for measuring coaxial connectors KISK-7M; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical and radio engineering quantities: Operating frequency range from 0.03 to 17.85 GHz Passing microwave power from 0.01 to 10 MW VSWR of the microwave tract from 1.05 to 3 Constant electrical voltage from 10 MV to 1000 V Alternating electric voltage from 1 mV to 750 V Thermoelectric voltage comparison from 0.1 to 0.5 V Ranges of reproduction of electrical quantities: Constant electrical voltage from 1 to 120 V Resistance to direct electric current from 0.01 to 122222.21 ohms Measurement errors of electrical and radio engineering quantities: Passing microwave power ± (1.5 - 2.3) % VSWR of the microwave path ± (4,15 – 10) % Constant electrical voltage ± (0.003 – 20) % Alternating electric voltage ± (0.09 - 15) % Thermoelectric voltage comparison ± (0.01 – 0.1) % Errors in the reproduction of electrical quantities: Constant electrical voltage ± (100 – 200) mV Resistance to direct electric current CT 0.005; 0.02 General technical characteristics: The area occupied by the module is 4 – 8 m2 Weight, not more than 340 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, not more than 2000 VA
Produced in: Moscow
ST-01 Universal Electrostatic Field Strength and Potential Meter
ST-01 Universal Electrostatic Field Strength and Potential Meter
from 72 000 ₽
It is made on a modern element base with a matrix display and microprocessor control, which allows processing the received data. With the help of the prefix, it allows you to evaluate the effect of electrification or antistatic treatment of textile and shoe polymer materials and products made from them, both in laboratory conditions and in conditions of real use of clothing and shoes. Recommended by Gossanepidnadzor for use for sanitary supervision to control the electrostatic field strength at the workplaces of PC operators, the electrostatic potential on the screen of video display terminals (VDT) and also in other areas of production regulated by GOST 12.1.045-84 and SanPiN 2.2.4.1191-03 "Electromagnetic fields in production conditions".
Produced in: Moscow
AF18-30dB
AF18-30dB
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Nominal attenuation, dB 30 Attenuation error, dB ± 1.5 VSWR 1.4 Frequency range, GHz 0-18 Input power, W 1 Type of coaxial connectors (according to GOST RV 51914-2002) IIIB-IIIP
Produced in: Moscow
Installation of control of surface radioactive contamination of personnel RZA-08D
Installation of control of surface radioactive contamination of personnel RZA-08D
Installation for monitoring radioactive contamination of hands, feet (shoes) and clothing of personnel with alpha- and beta - active substances. Modern and intuitive interface, various versions. Purpose: monitoring the level of contamination of hands, feet (shoes) and clothing of personnel with alpha- and beta-active substances and signaling when exceeding permissible levels; measurement of alpha and beta radiation flux density from the surface of the hands, feet (shoes) and clothing of personnel; measurement of the surface activity of alpha- and beta-emitting radionuclides of hands, feet (shoes) and clothing of personnel.
Doza
Zelenograd
Produced in: Moscow
CR-1B Reactor by Tetraquant
CR-1B Reactor by Tetraquant
1 supp.
The CR-1B reactor is an automated chemical reactor with thermostat, stirrer and reagent management system. To control the reactor, specialized software is used (supplied with the reactor). This reactor may be of most interest for laboratory research for routine synthesis of nano/microparticles (e.g. vaterite), as well as experimental scaling tests with a view to further transferring it to production facilities.
Produced in: Moscow
NV-800 SPr Cabinet for devices (with 2 glass doors)
NV-800 SPr Cabinet for devices (with 2 glass doors)
from 17 202 ₽
The NV-800 SPr cabinet for devices with 2 glass doors. The cabinet is made of laminated chipboard with a 2 mm shockproof PVC edge on the facade. Included in the set: 2 glass doors for the upper compartment; 2 doors for the lower compartment; 4 shelf inserts; metal legs 100 mm high.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Pure Hydrogen Generator GVCH-36A
Pure Hydrogen Generator GVCH-36A
from 447 600 ₽
The characteristics of the device are similar to the model GVCH-12A (GVCH-25A). The difference is the generator capacity of 36 liters / hour, the purity of the produced hydrogen is lower (99.998% vol). Technical specifications Purity of hydrogen in terms of dry gas is about 99.998 % Concentration of water vapor at 20OC and 3 atm is no more than 7 ppm Total hydrogen capacity reduced to normal conditions is 36 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.03 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more 0.06 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 0.5 years Average pump life (for single-shift operation) is at least 0.5 years Power consumption: in stationary mode is no more than 250 VA maximum (at startup) is no more than 280 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 18 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
CD-1 Paint detector of defects 220V
CD-1 Paint detector of defects 220V
from 50 000 ₽
The principle of operation: The controlled extended product (pipe, rolled or wire) is passed through the working area of the flaw detector. When a defective area is detected, the flaw detector included in the automated system sends a signal to trigger the paint meter actuator, as a result of which the paint from the marker's aerosol can is applied to the surface of the controlled product through a window in the device housing. Features and benefits: - Any standard aerosol cans with a diameter of 68 mm can be used in the flaw detector; - Easy replacement of the cylinder; - The device does not require connection to the pneumatic line; - High performance; - The design of the CD-1 defect meter allows connection to any standard AC and DC electrical networks with rated voltages from 12 to 380 V. Scope of application: The CD-1 automatic paint sprayer is an auxiliary equipment and is used in conjunction with flaw detectors as part of in–line automated lines for marking defects in quality control of extended products made of various materials, ferrous and non-ferrous metals and alloys - welded, hot-rolled and cold-drawn pipes, rolled products, wire and products made of them. The flaw detector can be used both in the production process and during input control on the consumer side at machine-building, transport, chemical and oil and gas enterprises. *Custom-made versions for rated voltages can be of: 12, 24, 48, 110, 127, 220, 380V.
Produced in: Moscow
Vacuum electric arc furnace for melting special materials VDP-130-7.5
Vacuum electric arc furnace for melting special materials VDP-130-7.5
Residual pressure in the furnace, millimeters of mercury 7,5*10-6 Arc heating method
VakETO
Mosrentgen
Produced in: Moscow