VE-50I is an indicator of the level of the electromagnetic field of the industrial frequency of 50 Hz
VE-50I is an indicator of the level of the electromagnetic field of the industrial frequency of 50 Hz
from 34 500 ₽
The indicator of electromagnetic fields of industrial frequency VE-50I is designed to measure the effective values of magnetic field induction (elliptically polarized) and electric field strength of industrial frequency 50 Hz. It is used to control the electromagnetic safety of industrial electrical installations during a comprehensive sanitary and hygienic inspection of residential and industrial premises and workplaces
Produced in: Moscow
COMBI-01M (VE-meter (Modification AT-004), ST-01, MAS-01)
COMBI-01M (VE-meter (Modification AT-004), ST-01, MAS-01)
from 289 000 ₽
A set for measuring the levels of electrostatic and magnetic fields, the concentration of light negative and positive aeroions.
Produced in: Moscow
VE-meter. Modification of "AT-004" and "50Hz" with control unit "NTM-Terminal"
VE-meter. Modification of "AT-004" and "50Hz" with control unit "NTM-Terminal"
from 66 500 ₽
The three-component electric and magnetic field parameter meter is designed to monitor electromagnetic safety standards for special assessment of working conditions, production control and comprehensive sanitary and hygienic inspections of facilities. The meter is equipped with isotropic EMF (non-directional reception) sensors.
Produced in: Moscow
Stand for measuring the electrification of tissues (to the device ST-01)
Stand for measuring the electrification of tissues (to the device ST-01)
from 17 200 ₽
Method of measuring the electrostatic field strength", SanPiN 2.4.7/1.1.1286-03 "Hygienic requirements for clothing for children, adolescents and adults", MOOK 4.1/4.3.1485-03 "Hygienic assessment of clothing for children, adolescents and adults". (available on a separate order).
Produced in: Moscow
Spectrum Analyzer S4-101
Spectrum Analyzer S4-101
Technical specifications: The operating frequency range of the monitored signals is from 9·103 to 3·109 Hz The analyzer has a zero band and a viewing band in the range from 100 Hz to 3 GHz Limits of permissible error of setting the viewing band ± 1 % The scan range is set from 10 ms to 3000 s in all modes except the zero band of view, and from 20 microseconds to 3000 s in the zero band of view mode The bandwidth of the RFP at the level of minus 3 dB is selected in the range from 100 Hz to 1 MHz in increments of 1, 3, 10 The squareness coefficient of the FPC at the level of minus 60 dB / minus 3 dB is not more than 5:1 The reference level setting range is from plus 30 dBm to minus 100 dBm. Installation step 1 dB Limits of the permissible basic error of setting the reference level ± 1 dB The limits of the unevenness of the amplitude-frequency response (frequency response) of the analyzer in the frequency range from 100 kHz to 3 GHz ± 1 dB Maximum allowable input power is 30 dBm (1 W) Limits of the permissible basic error of measuring the signal level due to the nonlinearity of the logarithmic scale ± 1 dB Limits of the permissible basic error of measuring the signal level due to switching of the input attenuator ± 1 dB Limits of error in measuring the signal level due to switching filters, ± 0.2 dB relative to the 1 kHz filter The average level of intrinsic noise at the FPC bandwidth of 100 Hz, the video filter band of 10 Hz and the input attenuator of 0 dB: - in the range from 100 kHz to 20 MHz minus 75 dBm - in the range from 20 MHz to 1.5 GHz minus 110 dBm - in the range from 1.5 to 3 GHz minus 105 dBm The input impedance of the analyzer is 50 ohms The voltage standing wave coefficient (VSWR) of the input with an input attenuator greater than 10 dB, no more: - 1.5 in the frequency range from 10 MHz to 2.5 GHz - 1.8 in the frequency range from 2.5 GHz to 3 GHz Diagonal screen size 21.5 cm Screen resolution 800x480 USB interface Overall dimensions – 398x220x150 mm Weight not more than 6.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
P3-34 Electromagnetic field parameter meter
P3-34 Electromagnetic field parameter meter
from 37 500 ₽
It is designed for measuring the electromagnetic energy flux density, the average square values of the electric and magnetic field strengths in the continuous generation mode.
Produced in: Moscow
E-meter AT-005 Electric Field Parameter meter
E-meter AT-005 Electric Field Parameter meter
from 40 500 ₽
Designed for measuring the average square values of the electric field strength in the frequency range from 10 kHz to 30 MHz in continuous generation mode.
Produced in: Moscow