Metrology

528 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 23
    Applying
    Loading...
  • 196
    Names
    Loading...
  • 54
    Manufacturer
    Loading...
  • 33
    Made in
    Loading...
  • 50
    Additional
    Loading...
View:
528 products
Fischer coulometric Titrator
Fischer coulometric Titrator
from 690 000 ₽
The Fischer titrator is designed to measure the moisture content in non-aqueous media in substances that do not interact with the Fischer reagent, such as petroleum, petroleum products, oils (transformer, turbine, hydraulic, motor, etc.), organic solvents, etc. in accordance with GOST ISO 12937:2000, GOST 24614-81, GOST 33733-2016, GOST R 54284-2010, GOST R IEC 60814, GOST 14870-77, ASTM D 4928-00 (2010), ASTM D6304-07, ASTM D 1533-00, ASTM E 1064-05.
EKROSKHIM
Saint Petersburg
Produced in: Saint Petersburg
High-frequency signal generator G4-235, G4-236
High-frequency signal generator G4-235, G4-236
Created on the basis of the G4-230 generator. Remote frequency converters extend the frequency ranges up to 53.57 GHz (G4-235) and up to 78.33 GHz (G4-236). The generators are capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications The frequency range at the output of the base unit is from 5 to 20 GHz Frequency range at the output of the frequency converter (G4-235) from 37.5 to 53.57 GHz The frequency range at the output of the frequency converter (G4-236) is from 53.57 to 78.33 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the signal power level at the output of the base unit is from minus 110 to 13 dBm The range of setting the signal power level at the output of the frequency converter (G4-235) is from 0 to 13 dBm The range of setting the signal power level at the output of the frequency converter (G4-236) from 0 to 10 dBm The basic error of setting the reference power level is ± (1.0 – 2.5) dB Metrological characteristics of the generator in FM operation mode: - frequency range of the modulating signal from 1 Hz to 20 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 1 Hz to 200 kHz - the main error of the frequency deviation setting is ± (5 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the basic error of setting the amplitude modulation coefficient ± (0.15 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from 5°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 20 kg
Produced in: Moscow
The self-recording meter IS-203.1.0
The self-recording meter IS-203.1.0
from 8 940 ₽
The measuring recorder IS-203.1.0 is designed to measure and register temperature with a specified time interval between measurements by direct contact of the device with the measuring object. The features of the meter IS-203.1.0 Ease of operation. Reliability. The operating conditions of the meter IS-203.1.0 Ambient temperature, ° C: -30...+85. Relative humidity, %: no more than 80% at T = 35 ° C. Atmospheric pressure, kPa: 86...106.
Produced in: Kolomna, Moscow region
Electronic explosion-proof thermometer ExT-01/3-20
Electronic explosion-proof thermometer ExT-01/3-20
The thermometer sensor ExT-01/3-20 is made in the form of a fully submersible probe with a cable length of 20 meters and has a device for winding it. The thermometer has an explosion protection marking 0Ex ia IIB T4 Ga X and can be used in explosive zones 0, 1 and 2 of any classes of premises and outdoor installations in which the formation of explosive mixtures of categories IIA, IIB is possible. • Measurement range -50...+130 °C Minimum sensor immersion depth full immersion Overall dimensions of the electronic unit 135x65x40 mm Electronic unit weight 0.3 kg
Produced in: Tomsk
Immitance meter E7-25
Immitance meter E7-25
Technical specifications: Conductivity (Gp) - 10-11 – 10 Cm Resistance (Rs, Rp, Xs, |Z|) 10-5 – 109 Ohms Capacity (Ss, Cp) - 10-15 – 1 F Inductance (Ls, Lp) 10-11 – 104 Gn Dobrotn.(Q), loss angle tangent (tg) 10-4 – 104 Phase shift angle of the resistance set -180° – +180° Leakage current (I) - 10-7 – 10-3 A Measurement error - ± 0.15 % Operating frequencies – 25 Hz – 1 MHz Power consumption - 10 VA Overall dimensions - 225x110x35 mm Weight - 0.8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Installation of pollution control of personnel RZBA-07D
Installation of pollution control of personnel RZBA-07D
Purpose: measuring the level of contamination of hands, feet (shoes) and clothing of personnel with beta-active substances and signaling when exceeding permissible levels monitoring the level of contamination with alpha-emitting radionuclides monitoring the contamination of personnel at nuclear power plants, nuclear fuel cycle enterprises (NFC), radiological laboratories, other enterprises and institutions using radioactive substances.
Doza
Zelenograd
Produced in: Moscow
High-frequency signal generator G4-232
High-frequency signal generator G4-232
A remote frequency converter with coaxial output extends the frequency range up to 37.5 GHz. The included coaxial-waveguide transitions and the ability to connect a small frequency converter directly to the user's device expand the scope of the device. The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications The frequency range at the output of the base unit is from 5 to 20 GHz The frequency range at the output of the frequency converter is from 5 to 37.5 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the signal power level at the output of the base unit is from minus 110 to 13 dBm The range of setting the signal power level at the output of the frequency converter is from 0 to 13 dBm The basic error of setting the reference power level is ± (1.0 – 2.0) dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal: LF from 1 Hz to 20 kHz RF from 10 Hz to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value): LF from 1 Hz to 200 kHz RF from 10 Hz to 10000 kHz - the main error of the frequency deviation setting is ± (5 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the basic error of setting the amplitude modulation coefficient: internal ± (0.15 M + 0.2)% external ± (0.20 M + 0.5)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 20 kg
Produced in: Moscow
M-95-CM Signal Digital Anemometer Sensor
M-95-CM Signal Digital Anemometer Sensor
from 26 022 ₽
Application range: 1.8 ... 55.0 m/s Alarm threshold setting range: wind speed from 12 to 40 m/s The range of setting alarm thresholds in time is from 2 to 5 seconds. Accuracy characteristics: PG±(0.5+0.05V) m/s The average service life is at least 8 years. Application conditions: wind speed sensor from -60C to +50C
EMPGGO
Saint Petersburg
Produced in: Saint Petersburg
PKV-IP-5,2×2,6
PKV-IP-5,2×2,6
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 37.50-50.00 VSWR 1.45
Produced in: Moscow
Installation for measuring the volumetric activity of radioactive gases in the air UDG-1B
Installation for measuring the volumetric activity of radioactive gases in the air UDG-1B
Purpose: measurement of the volumetric activity of beta-emitting gases (argon, krypton, xenon). Properties: built-in air flow indicator; compensation for the effects of external gamma background; communication interfaces RS-232, RS-485, Ethernet; sound and light alarm of exceeding the set thresholds; working with your own pumping unit or with an external sampling line; setup using a portable computer; periodic verification without disassembly using an exemplary source; availability of discrete output signal of the device; the possibility of connecting an external emergency alarm unit BAS.
Doza
Zelenograd
Produced in: Moscow