Equipment

2245 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 389
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2245 products
High-precision smart surface probe L =150 mm SZPWT.150P with built-in flash memory
High-precision smart surface probe L =150 mm SZPWT.150P with built-in flash memory
from 15 249 ₽
High-precision smart surface probe L =150 mm SZPWT. 150P with built-in flash memory is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPVT.150P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPVT.150P smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmission of data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect external power. Possibility of calibration.
Produced in: Kolomna, Moscow region
EVRAZCOMB – 2 in 1
EVRAZCOMB – 2 in 1
Purpose: Temperature measurement and sampling of molten steel. Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measuring range: from 1400 to 1800 °C - metal temperature Accuracy: 0 + 3°C at 1554°C The shape of the selected metal shape: Circle: thickness 12 mm Oval: thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other length is possible on request) Slag Cap: Steel, Aluminum, Cardboard Type of NSH: B, S, R
Produced in: Lipetsk
Universal calibrator H4-24
Universal calibrator H4-24
The main field of application of the calibrator is the verification of measuring instruments. The calibrator is capable of operating both independently and as part of automated measuring systems with interfaces such as USB, RS-232, IEEE-488 and ETHERNET. Technical specifications Ranges of reproduction of electrical quantities: - constant electrical voltage from 0 to 1000 V - alternating electric voltage in the frequency range from 10 Hz to 70 kHz from 0.9 mV to 1050 V - alternating electric voltage in the frequency range up to 100 kHz up to 750 V - alternating electrical voltage in the frequency range up to 1 MHz to 110 V - the power of direct electric current from 0 to 2 A - the power of alternating electric current in the frequency range from 10 Hz to 10 kHz from 0.9 µA to 2 A - electrical resistance of 1, 10, 100 ohms, 1,10,100 kOhm, 1,10,100 mOhm Errors in the reproduction of electrical quantities: - constant electrical voltage ± (0.0012 – 0.003)% of U + (0.0003 – 0.015)% of Up - alternating electric voltage in the frequency range from 10 Hz to 1 MHz ± (0.007 – 0.3)% of U + (0.001 – 0.25)% of Up - DC current ± (0.004 – 0.007)% of I + (0.001 – 0.01)% of Ip - AC electric current in the frequency range from 10 Hz to 10 kHz ± (0.015 – 0.1)% of I + (0.002 – 0.1)% of Ip - electrical resistance ± (0.002 – 0.005)% General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 500 VA Overall dimensions, mm 480x200x550 Weight, not more than 35 kg
Produced in: Moscow
Laboratory electronic thermometer LTA-E
Laboratory electronic thermometer LTA-E
It can be used as an accurate universal thermometer for contact temperature measurement of non-aggressive liquid, bulk and gaseous media. It can be connected to a computer for calibration and transmission of measurement results. • Range of temperature measurements -50...+200 °C The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
EVRAZCOMB – TSC
EVRAZCOMB – TSC
Purpose: Temperature measurement, sampling of molten metal Scope of application: Oxygen converters Measuring range: from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the oxygen activity level) The shape of the selected metal mold: Circle: diameter 34 mm, thickness 12 mm Oval: diameter 34mm, length 42mm, thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other lengths are available on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
Produced in: Lipetsk
General purpose exhaust cabinet LAB-PRO SHV 90.74.230 TR
General purpose exhaust cabinet LAB-PRO SHV 90.74.230 TR
BASIC EQUIPMENT Working box guide racks – aluminum profile painted with powder paint (RAL 7035/RAL 5023)in the right rack there are a light switch and 2 splash-proof sockets with a 3.2kW cover (IP54) the front anti–spill side is acid-resistant polished stainless steel AISI 304 side panels – tempered glass 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – metal painted with powder paint (RAL 5023) with the texture of shagreen leather back and top panels – polypropylene LED lamp dust- and moisture-proof (10W IP65) switching box with automatic emergency power off 16A flange d=250mm (the distance from the rear panel to the center of the flange is 170mm) easily removable exhaust visors 3 exhaust levels (lower, side and front) counterweights are placed in the front pylon racks and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel - metal box painted with powder paint (RAL 5023) with the texture of shagreen leather: adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Voltmeter V7-72
Voltmeter V7-72
Technical specifications: DC voltage Measuring range 2 mv-1000 V Measurement error ± (0.001 - 0.004)% AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.1-8)% Frequency range 10 Hz -1 MHz
MNIPI
Minsk
Produced in: Belarus, Minsk
Laboratory table low Mod. -900 SLL n "Laminate"
Laboratory table low Mod. -900 SLL n "Laminate"
from 17 660.87 ₽
The table is based on a reinforced O-shaped, collapsible metal frame made of shaped tube, rectangular and square cross-sections. The back wall is covered with a metal shield. The table is mounted on adjustable screw bearings, allowing the table to be installed horizontally, regarding the floor unevenness. Frame cover, high-quality powder-polymer paint, perfectly protects the base of the table from the effects of any aggressive liquids. The cover of the frame is easily cleaned with disinfectant solutions. The working surface of the Laminate table is a waterproof chipboard plate covered with chemically resistant and heat-resistant plastic.
Produced in: Saint Petersburg
50M URS special manual vacuum angle valve
50M URS special manual vacuum angle valve
The body of the 50M URS valve is of welded construction and consists of a shell, a seat, side and lower nozzles. The lower branch pipe of the 50M URS valve is connected to the vacuum system using welding. The smooth part of the stem serves as a visual indicator of the "open" or “closed” valve positions. The casing is designed to protect the valve from accidental openings, and also serves as additional protection against precipitation, sand, dust entering the inner cavity of the valve. The valve opens when the flywheel rotates counterclockwise. The valve closes when the flywheel rotates clockwise.
Produced in: Kazan
Flowmeter-counter ultrasonic Oriole
Flowmeter-counter ultrasonic Oriole
from 200 000 ₽
The ultrasonic Oriole flow meter is designed to measure the volumetric flow rate and volume of liquid in pressure pipelines. The measured medium can be any homogeneous isotropic liquid of various densities, including: clean cold and hot water supply and heating systems (up to +160 °C); natural water is clean and of a low degree of pollution; wastewater of low and medium degree of contamination; chemical solutions of acids, alkalis and other chemically aggressive media; mineral, synthetic and semi-synthetic machine oils; food products (vegetable oil, juices, syrups, vodka, ketchups, dairy products, etc.). Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters Mortise, contactless overhead outside and full-bore primary converters embedded in the process allow you to place the measurement gate on any water pipe made of any material, taking into account design features. Pipe sizes Du, mm: 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 6000 mm
Produced in: Moscow