Equipment

2278 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 392
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2278 products
2NVBM-630(R)/12000 Booster High Vacuum pump
2NVBM-630(R)/12000 Booster High Vacuum pump
The 2NVBM-630(R)/12000 booster pump consists of housings, a steam pipe, a trap and a heater. The required effective speed of action of the pre-vacuum pump (pumps) at a pressure of 200 Pa (1.5 mm Hg) at the outlet of the 2NVBM-630(R)/12000 booster pump is not less than 100 l/s. The maximum residual pressure of the pump measured by the PMI-2 manometric ionization converter with nitrogen filled into its trap, is no more than 6.6x10-4Pa (5x10-6mm Hg). The pressure of the cooling water at the pump inlet 2NVBM-630(P)/12000 should be from 0.2 to 0.5 MPa (from 2 to 5 kgf / cm2) The discharge from the pump should be free with a jet break. Cooling water consumption 1200 l/h. The total amount of working fluid for the 2NVBM-630(R)/12000 pump is 65 liters, the level of the working fluid should be between the upper and lower marks of the level gauge. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium, so the time after which the working fluid is replaced or refilled can be 100 hours or more. A large flow rate of the working fluid is observed when the pump is operating in the input pressure range from 1.33 to 13.3 Pa (from 1x10-2 to 1x10-1 mmHg). The operating mode of the pump in the range from 13.3 Pa (0.1 mmHg) to the maximum residual pressure is cyclically irregular.
Produced in: Kazan
Green DPSS Laser 532 nm KLM-532/SLN-x
Green DPSS Laser 532 nm KLM-532/SLN-x
DPSS lasers of the KLM-532/SLN-x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
2NVBM-400/6000 Booster high vacuum pump
2NVBM-400/6000 Booster high vacuum pump
The 2NVBM-400(R)/6000 booster pump consists of housings, a steam line, a trap and a heater. The required effective speed of action of the pre-vacuum pump (pumps) at a pressure of 200 Pa (1.5 mm Hg) at the outlet of the booster pump 2NVBM-400(R)/6000 is not less than 45 l/s. The maximum residual pressure of the pump 2NVBM-400(R)/6000, measured by the PMI-2 manometric ionization converter with nitrogen filled into its trap, is no more than 6.6 × 10-4 Pa (5 × 10-6 mmHg). The pressure of the cooling water at the inlet to the pump 2NVBM-400 (R)/6000 should be from 0.2 to 0.5 MPa (from 2 to 5 kgf / cm2). The drain from the pump should be free with a jet break. Cooling water consumption is 600 l/h. The total amount of working fluid for the 2NVBM-400(R)/6000 pump is 47 liters, the level of working fluid should be between the upper and lower marks of the level gauge. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium, so the time after which the working fluid is replaced or refilled can be 100 hours or more. A large flow rate of the working fluid is observed when the pump is operating in the input pressure range from 1.33 to 13.3 Pa (from 1 ·10-2 to 1 ·10-1 mm Hg). The pump operating mode in the range from 13.3 Pa (0.1 mmHg) to the maximum residual pressure is cyclically irregular.
Produced in: Kazan
AUTOMATIC DEVICE FOR AEROSOL DISINFECTION AERODEZ-"KRONT"
AUTOMATIC DEVICE FOR AEROSOL DISINFECTION AERODEZ-"KRONT"
from 210 000 ₽
The AERO-DEZ-"KRONT" device creates a stable aerosol of 6% hydrogen peroxide with particle sizes of 10-30 microns, which has the greatest antimicrobial effect and disinfecting effect when treating air and surfaces in order to destroy pathogenic flora: bacteria (including Mycobacterium tuberculosis), viruses, fungi, mold. With the help of the built-in fan, the aerosol is forced to circulate in the treated room, the aerosol is evenly distributed throughout the entire volume of the room and the entire volume of the room is treated more efficiently, including hard-to-reach and remote places.
KRONT
Химки
Produced in: Moscow region
Laboratory scales VLTE-3100
Laboratory scales VLTE-3100
from 67 490 ₽
Technical specifications: NIP, g3100 Discreteness, g0,01 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5 The price of the verification scale division, mg100 Limits of permissible error during primary verification, mgot 0.5g to 500g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 3100g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~3 Weight adjustment 2kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
XFP Transceiver
XFP Transceiver
XFP (10-Gigabit Small Form Factor Pluggable) is a protocol—independent hot-swappable optical transceiver, usually operating at 850nm, 1310nm or 1550nm wavelengths or wavelengths from the CWDM band at a speed of 10 gigabits per second in SONET/SDH, Fiber Channel, Gigabit Ethernet, 10 Gigabit Ethernet and other applications, including WDM channels.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Atom Fast 8850 - radiation dosimeter on a scintillator for a smartphone
Atom Fast 8850 - radiation dosimeter on a scintillator for a smartphone
from 29 500 ₽
1 supp.
Technical specifications Overall dimensions of the device (mm) 113*25*14 The service life of the built-in battery is at least 300 cycles within the warranty period of the device. The sensitivity anisotropy according to Cs137 (%) is not more than 30 The full charge time of the built-in battery from the USB port of the PC or charger is no more than 4 hours. Operating time Continuous operation from a fully charged built-in battery in conditions of natural radiation background: - without the use of sound/vibration alarm for at least 2 months; - without using wireless communication and sound/vibration alarm for at least 4 months. Maximum counting speed (imp/sec) 10000 The weight of the device (g) is not more than 50 Note The Atom Fast 8850 can use a cylindrical crystal with a diameter of 10 mm and a height of 40 mm without prior notice. The energy range of the recorded photon radiation (keV) is not less than 60 - 3000 keV Working size of the scintillation detector (mm) 8*8*50 The scope of delivery USB cable for charging the built-in lithium-ion battery 1 pc. Dosimeter set—top box Atom Fast - 1 pc. Packing box 1 pc. Carrying case — 1 pc.
Produced in: Moscow, Troitsk
Drying cabinet LF-25/350-VG1
Drying cabinet LF-25/350-VG1
Design features: Microprocessor temperature controller; Four-sided heating; Shut-off forced air circulation in the working chamber; The material of the chamber is steel painted with heat–resistant paint; Bright LED display; Conveniently located control panel; LED indicators of heater operation and protection operation; Alarm when the current temperature exceeds the limits of the permissible range; Reliable door closing mechanism; High-quality silicone sealer; Highly efficient thermal insulation of the housing; The case is made of high-quality sheet steel and painted with heat-resistant powder paint; Number of shelves: standard – 1, maximum – 5. Technical specifications: Maximum heating temperature, °C +350 The error of reproducing the set temperature ° C ± 3 Temperature maintenance error, ° C ± 1 Warm-up time to the maximum temperature, no more, min 45 Dimensions of the working chamber, (WxHxD), not less than 250x275x250 mm Overall dimensions, (WxHxD), not more than 595x495x565 mm Rated supply voltage, 220 V Rated power, W 1200
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum cooling trap FVC-12/20
Vacuum cooling trap FVC-12/20
from 432 432 ₽
The vacuum condenser type trap with a capacity of 12 liters is designed to condense vapors of non-aggressive gases on the internal cooled surfaces of the trap, in order to prevent them from entering the pump.
Produced in: Tula
THE DEVICE FOR ACHIEVING BALANCE
THE DEVICE FOR ACHIEVING BALANCE
When analyzing gases dissolved in transformer oil using the ARP method (equilibrium vapor analysis), mixing of the contents of the syringe with oil is used to accelerate the extraction of gases (to achieve an equilibrium distribution of gases dissolved in oil between the liquid and gas phases). For this purpose, as well as automation of the mixing process, a special autonomous device for achieving equilibrium is produced. technical specifications The rotation speed of the syringe drum is 30 rpm./min. The rotation time (determined by the internal timer, after pressing the "Start" button) is 10 minutes. The number of syringes placed is 4. The volume of syringes is 20 or 50 ml. Power consumption, no more than — 14 VA. Overall dimensions, no more than 210×280×270 mm. Weight, not more than — 5 kg.
Produced in: Yoshkar-Ola, Mari El
Collection for storage of purified water S-100
Collection for storage of purified water S-100
from 79 000 ₽
Designed for collecting, storing and distributing purified water obtained by various purification methods, with a capacity of 100 liters and 100% stainless steel, which allowed for a long service life. Dimensions in terms of 560x580 mm Weight 13.5 kg
Livam
Belgorod
Produced in: Belgorod