Equipment

2285 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 394
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 91
    Additional
    Loading...
View:
2285 products
Metolab 702 Universal Hardness Tester
Metolab 702 Universal Hardness Tester
The universal METOLAB 702 device is a stationary hardness tester, a modification of METOLAB 701, equipped with a large LCD display, a built–in printer, and also having the functionality for statistical processing of measurement results (calculation of minimum/average/ maximum values, conversion of results into various scales, storing data in memory, etc.). The device is designed to determine hardness by scales Rockwell, Vickers and Brinell of various materials and products – steels, cast iron, non-ferrous metals, soft alloys, etc. The METOLAB hardness tester has high accuracy, performs measurements in a wide range, and also provides high repeatability of results. Distinctive features of the stationary METOLAB 702 hardness tester: Scales for Rockwell measurements: HRA, HRB, HRC; Scales for Brinell measurements: HBW2.5/31.25, HBW2.5/62.5, HBW5/62.5, HBW2.5/187.5, HBW 10/100, HBW 1/30; Vickers measuring scales: HV30, HV100; Displaying all the necessary information on a large LCD screen; Possibility of statistical processing of measurement results – calculation of minimum/average/maximum values, conversion of results into various scales, storing data in memory and much more; Electromechanical drive for application and removal of load; Prompt change of the applied load by turning the force change knob; The ability to print the results on the built-in mini printer; Built-in digital micrometer with backlight, magnification 37.5 and 75x. Basic delivery package: Stationary universal METOLAB 702; Conical diamond Rockwell indenter (120° angle) - 1 pc.; Vickers diamond indenter (136° angle) - 1 pc.; Indenter with 1.5875 mm ball - 1 pc.; Indenter with 2.5mm ball - 1 pc.; Indenter with 5.0 mm ball - 1 pc.; Large flat table 150 mm - 1 pc.; Medium flat table 60 mm - 1 pc.; V-shaped table 40 mm - 1 pc.; Hardness measures - 1 set; 15x microscope - 1 pc.; 2.5x lens - 1 pc.; 5.0x lens - 1 pc.; User Manual.
Metolab
Moscow
Produced in: Moscow
Individual gamma radiation dosimeter DKG-05D
Individual gamma radiation dosimeter DKG-05D
Purpose: measurement of individual dose equivalent (IED); measurement of the power of the individual dose equivalent (MIED).
Doza
Zelenograd
Produced in: Moscow
DC power supply B5-83
DC power supply B5-83
The B5-83 DC power supply is designed to provide constant voltage and current to devices and equipment during the development, production, operation and repair of electronic devices. - Allows harsh operating conditions - Wide range of currents and voltages at a maximum power of 200 watts Technical specifications Output voltage setting range from 3 to 300 V Output current setting range from 0.05 to 2 A Electrical output power, not more than 200 watts The main error of the output voltage setting is ± 2 V The main error of setting the output current is ± 0.02 A Additional error in setting the output voltage caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0001 · Uust + 3 mV) Additional error in setting the output voltage caused by a change in the load current from 0.9 of the maximum value to zero ± (0.0002 · Uust + 10 mV) Additional error in setting the output current caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0002 · Iust + 1 mA) Additional error in setting the output current caused by a change in the load voltage from 0.9 of the maximum value to zero ± (0.0005 · Iust + 2 mA) The change in the output voltage in the voltage stabilization mode with a deviation of the ambient temperature in the operating temperature range by ± 10 ° C, not more than ± 250 mV Change of the output current in the current stabilization mode with a deviation of the ambient temperature in the operating temperature range by ± 10 ° C, not more than ± 10 mA Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 350 VA Overall dimensions, mm 240x128x313 Weight, not more than 5.5 kg
Produced in: Moscow
Smart submersible reinforced probe L=1500 mm SZPGU.1500P with built-in flash memory
Smart submersible reinforced probe L=1500 mm SZPGU.1500P with built-in flash memory
from 15 180 ₽
The smart submersible reinforced probe L =1500 mm SZPGU.1500P with built-in flash memory is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPGU.1500P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SZPGU.1500P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Laboratory table low Mod. -600 SLL n "Laminate"
Laboratory table low Mod. -600 SLL n "Laminate"
from 16 178.84 ₽
The table is based on a reinforced O-shaped, collapsible metal frame made of steel shaped tube, rectangular and square cross-sections. The back wall is covered with a metal shield. The table is mounted on adjustable screw bearings, allowing the table to be installed horizontally, regarding the floor unevenness. Frame cover: high-quality powder-polymer paint perfectly protects the base of the table from the effects of any aggressive liquids. The cover of the frame is easily cleaned with disinfectant solutions. The working surface of the Laminate table is a waterproof chipboard plate covered with chemically resistant and heat-resistant plastic.
Produced in: Saint Petersburg
Voltmeter V7-82
Voltmeter V7-82
Technical specifications: DC voltage , Measuring range, 10 mv-1000V Measurement error, ± 0.01% AC voltage , Measuring range, 1 mV - 700 V Measurement error, ± 0.4% Frequency range, 20 Hz- 1 MHz Direct current , Measuring range, 0.2 µA - 10 A Measurement error, ± 0.15%
MNIPI
Minsk
Produced in: Belarus, Minsk
Frequency comparator Ch7-1015
Frequency comparator Ch7-1015
Since it is reliable and easy to operate, the device is widely used in metrological centers, measuring laboratories, at the workplaces of REA developers. The memory of the comparator Ch7-1015 contains information about the main technical characteristics of domestic and foreign rubidium frequency standards presented on the Russian market, which greatly simplifies the process of checking devices in calibration laboratories. The device has a USB 2.0 communication interface with an external personal computer and application software for an external PC. The comparator Ch7-1015 has the ability to remotely control all modes of operation via a TCP protocol streaming socket and can work within an automated system.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Gamma radiation detector threshold stationary SRPS-05D
Gamma radiation detector threshold stationary SRPS-05D
A simple and reliable device for monitoring the radiation situation in rooms where work is carried out with radioactive sources (substances, medications, installations). If the set threshold value of the dose rate is exceeded, the device gives a sound and light signal, controls external devices (for example, door locking devices). Purpose: measurement of the ambient dose equivalent of gamma radiation (MAED); sound and light alarm about exceeding the set threshold; activation of external signaling or actuating devices.
Doza
Zelenograd
Produced in: Moscow