Weighting ring K-070
Weighting ring K-070
It is designed to prevent the flask from surfacing when it is thermostated in a laboratory bath or liquid thermostat.
Produced in: Tomsk
AF18-20dB
AF18-20dB
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Nominal attenuation, 20 dB Attenuation error, dB ± 1.0 VSWR 1.4 Frequency range, GHz 0-18 Input power, W 1 Type of coaxial connectors (according to GOST RV 51914-2002) IIIB-IIIP
Produced in: Moscow
2ZVE-630/400R Electromechanical Vacuum shutter with gearbox
2ZVE-630/400R Electromechanical Vacuum shutter with gearbox
The 2ZVE-630/400R vacuum shutter with electromechanical drive equipped with 630 / 400mm conditional passages is designed to overlap vacuum systems in the range of operating pressures from 1x10-6do 1,07x105Pa (0,75x10–8do 800 mm Hg). The 2ZVE-630/400R shutter is pendulum-type. The 23VE-630/400R shutter is manufactured in climatic versions UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69. The working environment is air or non–aggressive gases. It is not intended for use in fire hazardous and explosive industries. The 23VE-630/400R shutter meets the requirements of technical specifications TU 3648-040-00218526-2003. According to the method of protecting a person from electric shock, it belongs to Class I electrical equipment according to GOST 12.2.007.0-75.
Produced in: Kazan
Two-jet arc plasmatron "Torch"
Two-jet arc plasmatron "Torch"
The plasmatron is designed for direct atomic emission spectral analysis of powder samples. The excitation of atoms occurs in a DC argon arc plasma. Weak matrix effects and low detection limits make it possible to use this excitation source for the analysis of various samples, both with mineral and organic matrix.
Produced in: Novosibirsk
ZVPlE-900 Flat Electric Vacuum Shutter
ZVPlE-900 Flat Electric Vacuum Shutter
The ZVPlE-900 shutter consists of a housing with connecting flanges, a shutter mechanism, a lip seal to ensure the tightness of the drive element, cover, and electric drive. The shutter mechanism consists of a carriage, an upper and lower flap, which are pulled together by springs and balls. The carriage moves along the housing guides on bearings. The ZVPlE-900 shutter is opened and closed both by electric drive and manually using a flywheel. To switch to manual control mode, there is a switching device on the electric drive. The manual drive is used to adjust and regulate the shutter. ZVPlE-900 valves are manufactured in climatic versions UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69.
Produced in: Kazan
Grille on the back wall of LAB-PRO RZP-SHVOS 15
Grille on the back wall of LAB-PRO RZP-SHVOS 15
Number of horizontal rods: 3 rods 1230mm long Number of vertical rods: 3 rods 1000mm long rods (d=10mm) – polished stainless steel AISI 304 rod holders – duralumin rod clamps – screws-M-4 lambs (stainless steel AISI 304) it is possible to install horizontal rods in the required position
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Optical set-top box for working with light-guide IR probes
Optical set-top box for working with light-guide IR probes
FT-801 IR Fourier spectrometers can additionally be equipped with a special optical set-top box that allows efficient use of light-guide systems. 4 types of light-guide probes allow measuring transmission and reflection spectra in solid, liquid and gaseous media Modern IR light guides have high intrinsic transmittance and sufficient mechanical strength, which makes it possible to transfer measurements from the laboratory directly to production - to control the flow of technological processes, check the quality of raw materials and finished products. Application areas: · Chemical and microbiological industry · Pharmaceutical industry · Medicine and Cosmetology · Food industry · Petroleum products, fuels and lubricants · Criminology
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Support-rotary device OPU-1
Support-rotary device OPU-1
Technical specifications: Azimuth rotation angle from 0° to 360° with vernier ± 15° The angle of rotation according to the angle of the place from minus 30° to plus 90° The angle of the polarization plane is from minus 5° to plus 95° The installation height of the axis of the orientation mechanism is from 1.15 to 2.1 m in the version of USHIAI.301554.001 and from 1.4 to 2.35 m in the version of USHIAI.301554.001-01 Smooth adjustment of the height of the axis of the orientation mechanism 0.15 m In terms of strength under climatic and mechanical influences, the tripod complies with the norms of group 6 GOST 22261-94 The overall dimensions of the tripod are - 2080x2080x2100 mm (USHIAI.301554.001), – 2080x2080x2350 mm (USHIAI.301554.001-01) (shown in the unfolded state at maximum height. The size Ø2080 is the diameter of the circumscribed circle along the vertices of the triangle occupied by the tripod on a horizontal platform) Operating conditions of the tripod: ambient temperature from minus 50 to plus 60oC Tripod weight – 20.5 kg (USHIAI.301554.001), 21.5 kg (USHIAI.301554.001-01)
MNIPI
Minsk
Produced in: Belarus, Minsk
PRIZ - a reflection prefix with the lower position of the sample and visualization of the object under study on the monitor
PRIZ - a reflection prefix with the lower position of the sample and visualization of the object under study on the monitor
The main advantage of the PRIZ prefix is the possibility of obtaining well–defined spectra of micro-objects after giving them the shape of a thin layer on mirror-polished metal plates (in the mode of the so-called double passage, when radiation twice penetrates through the layer of matter, reflecting from the mirror-substrate). The presence of a visual control system with a built-in video camera significantly increases the information content when setting up and the reliability of the results obtained. With the help of the prefix, it is also possible to register the reflection spectra of bulk samples and solid objects of arbitrary geometry in native form, including pharmaceuticals in the form of tablets, powders and granules, polymer fragments, LCP, films deposited on the surface. Technical specifications Transmission in the operating range of the spectrum, % of the input signal at least 40 The recommended number of scans when registering spectra is 25 Spectrum registration time at 25 scans (resolution 4 cm-1), sec 30 Minimum initial dimensions of a solid sample, mm 0.2 × 0.2 The maximum area of the solid sample, mm 20X20X10 Variable focus range, mm 10 The diameter of the focus spot, mm 3 The angle of incidence of radiation (central beam) on the sample in the ZDO 45o mode Micro lens magnification / total magnification of the 4X visual channel Field of view of the optical system, mm 2 X 2.5 The resolution of the digital video camera is 640x480 Overall dimensions, mm 140×105×160 Weight, kg 1.16
SIMEKS
Novosibirsk
Produced in: Novosibirsk
3KN-2,5NZ Vacuum Inlet valve
3KN-2,5NZ Vacuum Inlet valve
The 3KN-2,5 intake valve includes a nut, the filter is installed in the housing between the two rings. The opening of the inlet valve 3KN-2,5 is carried out when the electromagnet coil is de-energized and the armature returns to its original position under the mechanical pressure of the spring. The closure of the 3KN-2,5 intake valve occurs when an electric voltage of a certain power is applied to the terminals of the coil. The anchor is involved in the shoe, ensuring the closure of the ductal canal.
Produced in: Kazan
VD-7.2×3.4
VD-7.2×3.4
A flexible waveguide is a piece of high-quality dielectric, which ends with transitions to standard waveguides with flanges. For ease of operation, the waveguide is protected by an elastic shell. Basic properties Manufacturability of the connection; Small losses and VSWR; Economy. Operating conditions Operating temperature range from 5 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Flange type according to GOST RV 51914-2002 Frequency range, GHz 25.95-37.50 VSWR 1.25 Losses, dB 2.0 Length, mm* 500