Accessories

357 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 20
    Areas of use
    Loading...
  • 92
    Item names
    Loading...
  • 37
    Manufacturer
    Loading...
  • 24
    Made in
    Loading...
  • 31
    Additional
    Loading...
View:
357 products
Manual mechanical press
Manual mechanical press
Designed for the preparation of samples in the form of compressed tablets with a diameter of 3.5 mm, consisting of the test substance in a mixture with microcrystalline potassium bromide (KBr). - the principle of operation of the device is based on creating the pressure necessary for pressing due to a mechanical lever system - the press is made of high-quality alloy hardened steel - for the manufacture of a tablet with a diameter of 3.5 mm, a minimum amount of the test substance and KBr is required - for the study of finished samples on a Fourier spectrometer, a vertical or horizontal microfocusing prefix is used
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Vibration velocity sensors with current output DVST-2
Vibration velocity sensors with current output DVST-2
Vibration velocity sensors with a current output DVST-2 are designed to convert the RMS value of the vibration velocity of an object into a standard current signal of 4-20 mA.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
ZVPlE-630 Flat Electric vacuum Shutter
ZVPlE-630 Flat Electric vacuum Shutter
The ZVPlE-630 shutter consists of a housing with connecting flanges, a shutter mechanism, a lip seal to ensure the tightness of the drive element, cover, and electric drive. The shutter mechanism consists of a carriage, an upper and lower flap, which are pulled together by springs and balls. The carriage moves along the housing guides on bearings. The ZVPlE-630 shutter is opened and closed both by electric drive and manually using a flywheel. To switch to manual control mode, there is a switching device on the electric drive. The manual drive is used to adjust and adjust the shutter. ZVPlE-630 valves are manufactured in climatic versions UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69.
Produced in: Kazan
Bellows hose with thermal insulation
Bellows hose with thermal insulation
Bellows hose with thermal insulation and an internal diameter of 10 mm is used to connect thermostats of the VTi CRYO-VT series to external consumers or as a jumper hose. We recommend it for use with PMS heat carriers at high temperatures.
Produced in: Tomsk
2ZVE-100 Electromechanical Vacuum shutter
2ZVE-100 Electromechanical Vacuum shutter
The 2ZVE-100 vacuum shutter with electromechanical drive equipped with conditional passages of 100 mm is designed to overlap vacuum systems in the range of operating pressures from 1x10-6 to 1.07x105 Pa (0.75 x10–8 to 800 mm Hg). Type of shutter 2ZVE-100 pendulum. The 23VE-100 shutter is manufactured in the climatic version of UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST 15150-69. The working environment is air and non–aggressive gases and. It is not intended for use in fire and explosive hazardous industries. The 23VE-100 shutter meets the requirements of technical specifications TU 3648-040-00218526-2003. According to the method of protecting a person from electric shock, the gate belongs to Class I electrical equipment according to GOST 12.2.007.0-75.
Produced in: Kazan
Weighting ring K-050
Weighting ring K-050
It is designed to prevent the flask from surfacing when it is thermostated in a laboratory bath or in a liquid thermostat.
Produced in: Tomsk
Hydraulic press GP 200-13
Hydraulic press GP 200-13
Designed for the preparation of samples in the form of compressed tablets with a diameter of up to 13 mm, consisting of the test substance in a mixture with microcrystalline potassium bromide (KBr). - the principle of operation of the press is based on the injection of pressure in the hydraulic system by swinging the lever. - to control the working pressure, the press is equipped with a pressure gauge - complete with a press, molds with a diameter of 13 mm and 3.5 mm can be used - for the study of finished samples on a Fourier spectrometer, a KBr tablet holder and D13mm substrate windows or a microfocusing attachment (for 3.5 mm tablets) is used
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Microphone condenser capsule M-101
Microphone condenser capsule M-101
It is designed to measure sound pressure in the air and is used in noise measuring equipment as a measuring transducer of infrasound, sound and ultrasonic pressure.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
A set-top box with a cooled MST detector
A set-top box with a cooled MST detector
To achieve the maximum sensitivity during measurements, a special prefix is used to the FT-801 Fourier spectrometer, which is an optical unit with a built-in highly sensitive MST detector cooled with liquid nitrogen. The set-top box is installed in the cuvette compartment of the spectrometer and connected to the corresponding external electrical port, the detector is turned on programmatically. In this case, the sensitivity of the method increases many times (up to 20) – depending on the type of standard uncooled detector in the spectrometer). The speed of recording spectra is also increasing. The operating time after filling the cryostat (200 ml capacity) with liquid nitrogen is at least 6 hours. Increasing the sensitivity of the spectrometer using a prefix with an MST detector may be required for many applications: in fiber spectroscopy, when recording emission spectra of low-power emitters, in trace gas analysis with high spectral resolution, when determining the presence of impurities in samples in ultra-low concentrations, when using multi-pass gas cuvettes, etc. In the picture: on the left in the cuvette compartment there is a capler with fiber from Art photonics GmbH, Berlin, Germany, on the right there is a prefix with an MST detector. Technical specifications The recommended number of scans when registering spectra is 16 Spectrum registration time at 50 scans (resolution 4 cm-1), sec 20 Cryostat capacity, 200 ml Working time after filling the cryostat, 6 hours Overall dimensions, mm 225×175×75 Weight, kg 1.45
SIMEKS
Novosibirsk
Produced in: Novosibirsk
50M URS special manual vacuum angle valve
50M URS special manual vacuum angle valve
The body of the 50M URS valve is of welded construction and consists of a shell, a seat, side and lower nozzles. The lower branch pipe of the 50M URS valve is connected to the vacuum system using welding. The smooth part of the stem serves as a visual indicator of the "open" or “closed” valve positions. The casing is designed to protect the valve from accidental openings, and also serves as additional protection against precipitation, sand, dust entering the inner cavity of the valve. The valve opens when the flywheel rotates counterclockwise. The valve closes when the flywheel rotates clockwise.
Produced in: Kazan
Silicone hose 8x2
Silicone hose 8x2
Silicone hose with an inner diameter of 8 mm is used to connect circulation coolers A160 and A300 with thermostats of the W series or to external consumers.
Produced in: Tomsk