Equipment

2243 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 388
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2243 products
Laboratory drying cabinets SHS-14/2,5
Laboratory drying cabinets SHS-14/2,5
The electric drying cabinet SHS-14/2.5 is designed for drying, heating various materials in air environment at a maximum temperature of 250 ° C. Technical specifications The electric cabinet operates at ambient temperature from 10 to 35 ° C and relative humidity up to 80% at 25 ° C. Operating temperature- 250 ⁰C Power consumption - 1000 watts Dimensions of the working chamber WxDxH- 195x340x195 mm Dimensions WxDxH- 325x600x445 mm Weight - 16 kg
MIUS
Tula
Produced in: Tula
HF-140-2 POZIS Pharmaceutical refrigerator
HF-140-2 POZIS Pharmaceutical refrigerator
from 25 734 ₽
Total volume, l. 140 The volume of the refrigerator compartment, l. 140 Number of compressors, pcs. 1 Height, mm 910 Depth, mm 610 Width, mm 600 Weight, kg., no more 40 Rated power consumption, W 150 Maximum rated power, W 165 Voltage, 220 V Warranty, years 2 Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Cold storage Auto refrigerator defrosting system Temperature in the refrigerator, °C +2... +15 Accuracy of temperature maintenance ±2°C Thermal card: yes Efficiency and energy consumption Electricity consumption, kWh/day, not more than 0.52 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 40 Gross weight of the product, kg 43.5 Volume of packaging, m3 0,397 The length of the package, m 0.65 The width of the package, m 0.63 Height of the package, m 0.97
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
Vacuum drying cabinet with automatic adjustment SNVS-50/5
Vacuum drying cabinet with automatic adjustment SNVS-50/5
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with the appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing of devices under low pressure conditions under various temperature conditions.
Produced in: Tula
Drying cabinet LF-120/300-GS1
Drying cabinet LF-120/300-GS1
Design features: Microprocessor temperature controller; Four-sided heating; Natural air convection in the working chamber; Camera material – stainless steel; Bright LED display; Conveniently located control panel; LED indicators of heater operation and protection operation; Alarm when the current temperature exceeds the limits of the permissible range; Reliable door closing mechanism; High-quality silicone sealer; Highly efficient thermal insulation of the housing; The case is made of high-quality sheet steel and painted with heat-resistant powder paint; Number of shelves: standard – 2, maximum – 8. Technical specifications: Maximum heating temperature, °C +300 The error of reproducing the set temperature, ° C ± 5 Temperature maintenance error, ° C ± 2 Warm-up time to maximum temperature, no more, min 45 Dimensions of the working chamber, (WxHxD), not less than mm 440x500x475 Overall dimensions, (WxHxD), not more than mm 785x680x735 Rated supply voltage, 220 V Rated power, W 2200
LOIP
Saint Petersburg
Produced in: Saint Petersburg
LAP-400P Nitrogen Flow Vacuum Trap
LAP-400P Nitrogen Flow Vacuum Trap
The nitrogen flow trap LAP-400P is designed to protect vacuum pumps from contamination in the form of vapors of resins, oils and adhesives by freezing them on cooled surfaces with the possibility of their removal, and to prevent the penetration of vapors of working fluids of vacuum pumps into the pumped vessel.
Produced in: Kazan
Nitrogen Generator GA-1200
Nitrogen Generator GA-1200
from 516 000 ₽
The nitrogen generator is designed to create an inert atmosphere, fill low-pressure tanks, "wash" test tubes with inert gas and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. Technical specifications Volume fraction of nitrogen is not less than 99.0 % by volume (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than, 1.0 % vol. Volume fraction of water vapor is not more than 0.002 % vol. (20 ppm) Maximum nitrogen capacity: at an inlet air pressure of 7 ati is at least 1380 l/h (23 l/min) The time of setting the operating mode for single-shift operation is no more than 30 min Minimum inlet air pressure is 7 ati Maximum allowable inlet air pressure is 8.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 150 l/min Power consumption is not more than 200 VA Overall dimensions, (width x depth x height) are not more than 230x580x680 mm Weight is not more than 38 kg Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Immersion thermostat circulator LT-200
Immersion thermostat circulator LT-200
Technical specifications: Temperature range: without external cooling, °C T okr+10 ... +200 with tap water cooling °C T of water+5 ...+200 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 10.5 pressure, 0.27 bar The working fluid is water, water-glycerin mixture, silicone oil. Dimensions, mm 123x190x325 Weight, kg 3.3
LOIP
Saint Petersburg
Produced in: Saint Petersburg
LAP-100P Nitrogen Flow Vacuum Trap
LAP-100P Nitrogen Flow Vacuum Trap
The nitrogen flow trap LAP-100P is designed to protect vacuum pumps from contamination in the form of vapors of resins, oils and adhesives by freezing them on cooled surfaces with the possibility of their removal, and to prevent the penetration of vapors of working fluids of vacuum pumps into the pumped vessel.
Produced in: Kazan
Laboratory scales VLTE-2100/5100
Laboratory scales VLTE-2100/5100
from 57 490 ₽
Technical specifications: NIP, g 2100/5100 Discreteness, g 0.01/0.1 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5/5.0 The price of the verification scale division, mg100/1000 Limits of permissible error during primary verification, mgot 0.5g to 500g incl. ±50/±500; sv. 500g to 2000g incl. ±100/±500; sv. 2000g to 2100g incl. ±150/±500; sv. 2100g to 5000g incl. ±500; sv. 5000g to 5100g incl. ±1000 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II high The time of setting the readings, s, no more than ~3 /~2 Weight adjustment 2kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
MARK-603
MARK-603
Measurement of electrical conductivity (UEP, UEP25), equivalent salinity and temperature of water and aqueous solutions, including deionized and "ultrapure". Operational control of water-chemical regimes at thermal power facilities. Control of electrical conductivity of water for laboratory analysis of 1, 2 degrees of purity according to GOST 52501-2005. 24-month warranty for deliveries across the Russian Federation Double automatic temperature compensation (ATC) Allows high-precision measurements of the conductivity of "ultrapure" water Selection of the coefficient of thermal compensation at the request of the User Stainless steel flow-immersion sensor Does not require calibration. The sensor design ensures the stability of the permanent cell Electronic notebook Ability to record up to 500 measurement groups in User-named folders Self-diagnosis Ion exchange column with sample current switch IP65 The compact sealed device is reliably protected from dust and moisture USB port, software included Graphic indicator with backlight Low power consumption Up to 600 hours of continuous operation from a set of AA type elements
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Vertical indicator VIS-T-I
Vertical indicator VIS-T-I
It is suitable for all types of viscometers. It is placed in a thick tube of a capillary viscometer and allows you to evaluate the verticality of its installation by the position of the bubble indicator
Produced in: Tomsk
Muffle furnace LF-15/13-G
Muffle furnace LF-15/13-G
Design features: Durable ceramic muffle; Semi-open heaters on four sides of the chamber; Microprocessor temperature controller; Conveniently located control panel and bright LED display; Ease of management and control; LED indicators of heater operation and protection operation; Automatic shutdown of heating when opening the door; The door opens up and faces the user with the cold side; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than mm 215x190x330 Overall dimensions, WxHxD, not more than mm 525x655x680 Rated supply voltage, 220 V Rated power, W 6100
LOIP
Saint Petersburg