Equipment

2243 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 388
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2243 products
Vacuum drying cabinet SNVS-40/5
Vacuum drying cabinet SNVS-40/5
They are designed for carrying out various technological processes at temperatures from 40 to 500 oC, in vacuum up to 1x10−3 mmHg, or in an inert gas of high purity. They are used for drying, light annealing, aging, low and medium tempering in an oxidizing environment, degassing of ferrous and non-ferrous metals (including copper and copper alloys), or any other materials processed under similar conditions. The program setting of heat treatment modes including vacuuming, high purity inert gas intake with repeated vacuuming allows heating in an oxidizing environment with high purity of the surfaces of the processed parts, without scale formation and oxidation.
Produced in: Tula
Platform scales ERW-101
Platform scales ERW-101
from 144 990 ₽
Technical characteristics: NIP, KG101 Discreteness, g1,0 External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g50 Accuracy class according to GOST OIML R 76-1-2011II high Limits of error allowed during initial verification, goth 50g to 50kg incl. ±5.0; sv.50kg to 52kg incl. ±10.0 Dust and moisture protection (IP)54/65 (on request) Setting time, s, no more than 3 Weight adjustment 40kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
CD-1 Paint detector of defects 220V
CD-1 Paint detector of defects 220V
from 60 000 ₽
The principle of operation: The controlled extended product (pipe, rolled or wire) is passed through the working area of the flaw detector. When a defective area is detected, the flaw detector included in the automated system sends a signal to trigger the paint meter actuator, as a result of which the paint from the marker's aerosol can is applied to the surface of the controlled product through a window in the device housing. Features and benefits: - Any standard aerosol cans with a diameter of 68 mm can be used in the flaw detector; - Easy replacement of the cylinder; - The device does not require connection to the pneumatic line; - High performance; - The design of the CD-1 defect meter allows connection to any standard AC and DC electrical networks with rated voltages from 12 to 380 V. Scope of application: The CD-1 automatic paint sprayer is an auxiliary equipment and is used in conjunction with flaw detectors as part of in–line automated lines for marking defects in quality control of extended products made of various materials, ferrous and non-ferrous metals and alloys - welded, hot-rolled and cold-drawn pipes, rolled products, wire and products made of them. The flaw detector can be used both in the production process and during input control on the consumer side at machine-building, transport, chemical and oil and gas enterprises. *Custom-made versions for rated voltages can be of: 12, 24, 48, 110, 127, 220, 380V.
Produced in: Moscow
Analytical scales VLA-320S
Analytical scales VLA-320S
from 349 990 ₽
Technical characteristics: NIP, G320 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the calibration division, mg1 Limits of permissible error of the scales during verification, ± mg, in weighing intervals: from 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 320g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.45 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, no more than 7 Adjustment weight built - in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
In situ bioprinter
In situ bioprinter
The first Russian In situ bioprinter for printing in the wound bed is a robotic complex for studying surface damage to restore tissues and organs directly in the patient's body. The in situ bioprinter is suitable for biomedical research in the field of tissue engineering in the laboratory. The bioprinter works with various types of hydrogels (including collagen of the first type) with the addition of cells, growth factors, etc. The printing time depends on the size of the defect and takes about 5 minutes on average. The device complex consists of a 6-axis robot, a 3D scanner and a biomaterial dispenser. The printing process includes scanning, tracing, and applying the material. Currently, the In situ bioprinter is at the stage of obtaining a medical device registration certificate for subsequent use in clinical practice. Improved wound healing dynamics strongly suggest that in situ bioprinting can be used as a new successful therapeutic method for the treatment of soft tissue defects. Significant advantages: ● Performs bioprinting even on a dynamically changing surface (optional: adaptation to micro-movements or breathing of the patient) ● Versatile in the use of different types of hydrogels (both sodium alginate and collagen; with and without cells, etc.) An important feature of the In situ bioprinter is that the bioprinter is suitable for various industries and can act as a "classic" 3D printer.
MISIS
Москва
Produced in: Moscow
2NVBM-630/18000 Booster high vacuum pump
2NVBM-630/18000 Booster high vacuum pump
The 2NVBM-630(R)/18000 pump is designed for pumping out of sealed volumes of air, gases, vapors and vapor-gas mixtures that are non-aggressive to the materials of the structure and the working fluid of the pump in the range of inlet pressures from 13.3 to 6.6x10-2 Pa (from 1x10-1 to 5x10-4 mmHg.) and do not contain droplet moisture and mechanical impurities. The 2NVBM-630(R)/18000 pump is used in conjunction with pre-vacuum pumps as part of technological installations or systems in stationary conditions. The type of climatic version of UHL4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, but it is intended for operation at ambient temperature from plus 10°C to plus 35°C for UHL4 and from plus 10°C to plus 45°C for O4, at cooling water temperature from plus 10°C to plus 20°C. The 2NVBM-630(R)/18000 pump is not intended for use in fire dangerous and explosive industries.
Produced in: Kazan
Drying cabinet LF-240/300-VS1
Drying cabinet LF-240/300-VS1
Design features: Microprocessor-based PID controller; Four-sided heating; Built-in fan; Conveniently located control panel with bright LED display; Ease of management and control; Light alarm when the current temperature exceeds the limits of the permissible interval; Stainless steel working chamber; Reliable door closing mechanism; High-quality silicone sealer; Highly efficient thermal insulation of the housing; Technical specifications: Set temperature range, °C +50...+300 The error of reproducing the set temperature ° C ± 5 Accuracy of temperature maintenance, °C ± 5 The maximum number of shelves (with a rack installed) is 10(20) Rated supply voltage, 220 V Total power consumption, W 5000 Overall dimensions, WxHxD no more than 1200x930x750 mm Overall dimensions of the working chamber, WxHxD not less than mm 770x565x430 Weight, kg 125
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Muffle furnace LF-5/11-G1
Muffle furnace LF-5/11-G1
Design features: Durable ceramic muffle; Closed heaters on four sides of the chamber; Microprocessor temperature controller; Conveniently located control panel and bright LED display; Ease of management and control; LED indicators of heater operation and protection operation; Automatic shutdown of heating when opening the door; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1100 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x110x190 mm Overall dimensions, WxHxD, not more than mm 505x565x565 Rated supply voltage, 220 V Rated power, W 2800
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-510S
Laboratory scales VLTE-510S
from 47 490 ₽
Technical characteristics: NIP, G510 Discreteness, g0,01 Calibration, self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.5 The price of the varification scale division, mg100 The limits of permissible error during primary verification, mgot 0.5g to 500 g incl. ±50; sv. 500g to 510g incl. ±100 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Adjustment weight built-in Indication setting time, s, no more than~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
pH meter MARK-903
pH meter MARK-903
Measurement of the activity of hydrogen ions (pH), ORP, EMF and temperature of aqueous media. Laboratory and "field" measurements in various industries and national economy. 24-month warranty for deliveries across the Russian Federation (the electrode system is guaranteed by the manufacturer IP65 The compact sealed device is reliably protected from dust and moisture Convenience and accuracy of measurement Automatic temperature compensation Automatic recognition of buffer solutions Self-diagnosis Non-volatile electronic notebook Ability to record up to 500 measurement groups in User-named folders USB port, software included Ability to create and manage a data archive on a PC Graphic indicator with backlight Indication of readings in a user-friendly format. Ease of settings. Protective cover Convenience during transportation and "field" measurements Low power consumption Up to 600 hours of continuous operation from a set of AA type elements
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
M532 Raman microscope by Spektr-M
M532 Raman microscope by Spektr-M
1 supp.
The M532® Raman microscope combines the capabilities of the Inspectr R532® Portable Raman Express Analyzer and the U300M microscope, adapting it for both transmission and reflection measurements. The wide functionality of the M532 microscope makes it possible to find and analyze individual particles with a size of 2-3 µm among many similar ones with similar physical and chemical properties, which opens up new research opportunities within the framework of a single Raman system. A spatial resolution of 1 µm and a spectral resolution of 4-6 cm-1 ensure excellent measurement accuracy and reproducibility. The compact design and portability of the instrument allow for high-quality and instant analysis of substances without sample preparation, which makes the M532 microscope an indispensable instrument for a wide range of studies. Equipped with a motorized slide (optional) with a step of 0.36 µm, the M532 microscope scans the surface of the sample, recognizes substances in multi-component heterogeneous mixtures and creates a graphical image of the intensities of Raman scattering characteristic lines at various points on the surface (2D mapping), which makes the M532 microscope the most advantageous in terms of price-quality ratio scanning Raman microscope in the world market.
Spektr-M
Chernogolovka
Produced in: Chernogolovka, Moscow region
Technical laboratory scales VLTE-4100T
Technical laboratory scales VLTE-4100T
from 34 990 ₽
Technical specifications: NIP, g 4100 Discreteness, g0,1 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g5 The limits of permissible error during initial verification, mgot 0.5g to 500 g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 4100g incl. ±150 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Weight adjustment 2kgF2* The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg