Equipment

2224 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 385
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 99
    Additional
    Loading...
View:
2224 products
Mobile Laboratory For The Control Of Physical Factors
Mobile Laboratory For The Control Of Physical Factors
The companies NTM-Zashchita LLC (Moscow) and Avtospectr-NN (Nizhny Novgorod) have implemented a joint project "Mobile Laboratory for Physical Factors Control", which is a mobile complex equipped with the most modern equipment of well-known Russian and foreign manufacturers, designed to effectively solve the problems of sanitary and hygienic control and labor protection, certification of workplaces and monitoring of the production environment.
Produced in: Moscow
MAES Analyzer for Scintillation
MAES Analyzer for Scintillation
MAES analyzers for recording atomic emission spectra with a time resolution of 1 ms are based on highly sensitive photodiodes and a special switching board for simultaneous reading of several sections of the spectra. The assembly of the rulers is installed on the "Grand" spectrometer. A " Flow" or twin-jet arc plasmatron is used to excite the atomic emission spectra of powder samples. The ATOM software registers the selected spectral lines and provides their processing according to the specified algorithms, taking into account the number and brightness of flashes (i.e. particle size). Recording the spectra of powder samples with a large time resolution makes it possible to estimate the number and size of individual particles, identify their composition and determine the concentrations of elements in each particle, promptly assess the uniformity of the distribution of certain elements to be determined and expand the possibilities of spectral analysis without significant changes in sample preparation. Main application areas: mass analysis of powder geological samples by scintillation to determine gold, silver, platinum group metals, iridium, rhodium, etc. with detection limits up to 0.01 g/t; qualitative determination of the composition of inclusions and mineral particles.
Produced in: Novosibirsk
LB61-Sh Laboratory bath
LB61-Sh Laboratory bath
It is intended for thermostating samples in glasses, flasks and other laboratory utensils in cases where high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. Six workstations with a diameter of 110 mm with five steel O-rings, tripods and feet with a clip. Stamped steel bath with a volume of 11 liters and a depth of 60 mm. Bath volume 11 l Overall dimensions 570x660x610 mm The open part of the bath is 500x290 mm Bath depth 60 mm Weight 12.5 kg Power consumption 2.5 kW
Produced in: Tomsk
Software and hardware complex with a set of sensors for biology classrooms
Software and hardware complex with a set of sensors for biology classrooms
It is designed for use as a demonstration material, setting up an experiment. The software and measurement complex includes a set of sensors and is designed for use as a demonstration material, setting up an experiment. The complex consists of a set of sensors and a software package. The measurement results are displayed in the form of graphs and digital values on the PC screen. The sensors are designed to work together with a PC via a USB 2.0 interface, running software compatible with Microsoft Windows 10 PRO. The complex is accompanied by: - product passport; - instruction manual; - an inventory of investments. The warranty period for the product is at least 24 months.
MNIPI
Minsk
Produced in: Belarus, Minsk
Tracing generator AG-105
Tracing generator AG-105
from 89 400 ₽
The automatic tracing pulse generator AG-105 is designed to create propagating signals (vibrations) in the routes of hidden communications with the active method of tracerouting. The device creates an alternating sinusoidal current in the studied communication (constantly or in short-term parcels) necessary to determine its location. The features of the AG-105 generator Extremely high power output and battery life, for a compact battery pack ("Type C" × 8) and such small overall dimensions. Universal power supply allows you to reach an output power of over 20 watts. With autonomous power supply, the "life cycle" depends on the quality of the "type C" batteries used. For example, with an initial output power of 7 watts in continuous generation mode, the "life cycle" is ≈ 5 hours, and with an initial output power of 15 watts in intermittent modulation mode, the "life cycle" is ≈ 25 hours (using standard new "fresh" batteries, for example, "Energizer C"). When using "ultra-high-capacity" batteries (for example, "Duracell ULTRA" or "COSMOS"), the battery life can be increased by 20-30%. When connecting an external "12V" battery (for example, a car), the operating time is determined by the capacity of this battery. When connecting an external mains power supply "15 V", the operating time is not limited. The dimensions of the portable device in the case are 216x180x105 mm, and the weight does not exceed 2 kg. These features are provided by the use of an ultra-efficient unique modification of the circuit technology for building CLASS D power amplifiers. The pulse output amplifier reaches an efficiency of 85%, which is especially important for "energy-consuming" devices with autonomous power supply.
Produced in: Kolomna, Moscow region
Mobile laboratory for 0.4-10 kV cable lines (ETL-10)
Mobile laboratory for 0.4-10 kV cable lines (ETL-10)
Laboratory for 0.4-10 kV cable lines (ETL-10) consists of: 1. Test facility • – Maximum rectified voltage up to 70 kV; • – Maximum AC voltage of the industrial frequency of 50 Hz to 50 kV. 2. Burning facility • – Maximum voltage up to 30 kV; • – Maximum current up to 80 A; • – Working hours are not limited; • – Switching of stages is carried out without breaking the arc at the time of switching; • – The ability to start working from any stage of burning (when working with low-voltage cables); • – Built-in afterburning. 3. High voltage pulse generator • – Output voltage 0...12 kV / 0...24 kV; • – The pulse energy at each stage is 3000 J; • – Built-in IDM for collaboration with the reflectometer. 4. Reflectometer – Supports 3 methods of determining the location of damage: • – By pulse reflectometry; • – By the method of oscillatory discharge; • – Pulse-arc method. 5. High-voltage cable defects detector • – Determining the location and depth of the cable at a depth of up to 10 m; • – Tracing at a distance of up to 10 km; • – Search for live electrical cables; • – Search for places where the pipeline and cable intersect; • – Determining the places of damage to cable lines; • – Site surveys before excavation; • – Search for places of damage to the external insulation of the cable; • – GPS\GLONASS coordinates recording and mapping of found communications; • – Cable selection from the bundle; • – Search for the place of damage by acoustic method.
Produced in: Kolomna, Moscow region
Sulfur Analyzer SPECTROSCAN SW-D3
Sulfur Analyzer SPECTROSCAN SW-D3
The analyzer is designed to determine the mass fraction of sulfur in automotive fuel in accordance with GOST R 52660-2006 / GOST ISO 20884-2016, ASTM D6334, as well as in oil and petroleum products according to GOST R 53203-2008 / GOST 33194-2014, ASTM D2622, GB/T 11140-2008. Depending on the customer's needs, the analyzer is configured to work in accordance with a particular standard. Implements an arbitration method for measuring the mass fraction of sulfur in automobile fuel of the third, fourth and fifth classes. The device is designed specifically for high-quality and fast X-ray fluorescence analysis of fuel in accordance with the technical regulations "On requirements for automotive and aviation gasoline, diesel and marine fuel, jet fuel and heating oil", which establishes an arbitration X-ray fluorescence wave dispersion method for determining the mass fraction of sulfur in automotive fuels of the third, fourth and fifth classes. The wave dispersion sulfur analyzer SPECTROSCAN SW-D3 is designed taking into account all the requirements for the process of X-ray fluorescence elemental analysis of low sulfur contents in petroleum products. The operator's actions when performing measurements are minimized: - the number/name of the sample is entered from the built-in keyboard; - the sample is poured into two cuvettes; - the obtained samples are placed in the analyzer and measurements are started. The analyzer performs all subsequent actions automatically without operator involvement: - calculates and displays the sulfur content in the sample; - calculates convergence - the difference in determining the mass fraction of sulfur in the first and second samples; - prints measurement results on the built-in printer.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Automatic apparatus for analysis of saturated vapor pressure of liquid petroleum products DNP-LAB-12
Automatic apparatus for analysis of saturated vapor pressure of liquid petroleum products DNP-LAB-12
Technical specifications: The volume of the analyzed sample is 5 ml The volume of the test chamber is 25 ml Test temperature 37.8°C Accuracy of maintaining the temperature of the chamber ±0.1 °C Pressure measurement range 0.01...200 kPa Pressure measurement accuracy ±0.01 kPa Gas/liquid ratio 4/1 Power consumption from 220 mains, no more than 150 watts USB, LAN interface Overall dimensions, no more 450x230x190 mm Weight, not more than 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Green DPSS Laser 523 nm KLM-523-x
Green DPSS Laser 523 nm KLM-523-x
DPSS lasers of the KLM-523/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Technological thermostat STT-40
Technological thermostat STT-40
The power of the built-in electric heaters is 12 kW, there is also an independent emergency shutdown channel. The operating temperature range is +50...+200 °C. The volume of the bath is 30 liters Overall dimensions 500x840x880 mm Weight 60 kg Power consumption 13 kW (three-phase network)
Produced in: Tomsk
Explosion-proof vacuum electric furnace START-65
Explosion-proof vacuum electric furnace START-65
Vacuum resistance furnaces are necessary for heating products before pressure treatment, for sintering, degassing, quenching, annealing, soldering and chemical-technological processes. Such furnaces among all the variety of thermal equipment are considered the most environmentally friendly – heat treatment is carried out at t up to +2500 ° C in a purified vacuum. Under certain conditions, vacuum furnaces are used to work with neutral gases. The outer part of the furnace is made of stainless steel and is cooled by liquid. The inner part of the working chamber, where the heat treatment of materials is carried out, is made of an alloy of molybdenum and tungsten. The components are characterized by a low inertia force, reduced gas separation. The settings are available on the control panel, where the instruments, automatic and manual control switches are located. At every enterprise of the electronic industry, nuclear power, an explosion-proof vacuum resistance furnace is needed. The same applies to areas where various products undergo heat treatment at the stage of production and preparation for use.
Produced in: Tula
Circulation thermostat LT-411b
Circulation thermostat LT-411b
The LOIP LT-411b modification device consists of an immersion thermostat-circulator LOIP LT-400 and a working bath with a lean-to hinged lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, not more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, l/min 6...12 pressure, 0.4 bar Bath volume, l 11 The working fluid is water, silicone oil. The open part of the bath / depth, mm 165x230/200 Overall dimensions, mm 268x335x400 Weight, kg 11.4
LOIP
Saint Petersburg
Produced in: Saint Petersburg