Equipment

2243 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 388
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2243 products
Liquid low-temperature thermostat CRYO-VT-01
Liquid low-temperature thermostat CRYO-VT-01
As external consumers, thermostatic circuits of laboratory chemical reactors, measuring instruments and other equipment can be connected to the thermostat. Feed pump for external closed-type thermostating systems. Operating temperature range -30...+100 °C. Stability and uniformity of temperature in the working bath is not worse than ± 0.01 ° C. Bath volume 18 l Overall dimensions 440x700x640 mm The open part of the bath is 115x190 mm Bath depth 300 mm Weight 57 kg Power consumption 3.5 kW
Produced in: Tomsk
Green Laser Module KLM-A532-5-5 532nm 5mW dot
Green Laser Module KLM-A532-5-5 532nm 5mW dot
from 13 184 ₽
KLM-A532-5-5 laser modules are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
RELAY PROTECTION UNITS FOR DIGITAL SUBSTATION OF THE IED-EP+ SERIES
RELAY PROTECTION UNITS FOR DIGITAL SUBSTATION OF THE IED-EP+ SERIES
A series of modern intelligent relay protection, automation and alarm units PARMA IED-EP+ is designed for use in networks with a voltage from 6 to 750 kV
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Measuring and diagnostic complex PKSOD-M
Measuring and diagnostic complex PKSOD-M
The proposed measuring and diagnostic complex is designed to: - provide monitoring of the technical condition of electric drive valves of nuclear power plants; – detection and identification of malfunctions of components and equipment of electric drive valves at an early stage of their occurrence; – issuance of measurement results and diagnostics of electric drive valves to the operational personnel of the station.
Produced in: Rostov-on-Don
Metal tripod Sh-10/23, pack.12 pcs, MiniMedProm
Metal tripod Sh-10/23, pack.12 pcs, MiniMedProm
from 288 ₽
The tripod is made of aluminum, which allows them to be sterilized at any temperature; this material provides lightness and durability. It can be used in water baths. The tripod has an individual packaging. Designed for storing test tubes.
MiniMed
Suponevo
Produced in: Bryansk region
RUNWAY-101 platform scales
RUNWAY-101 platform scales
from 114 990 ₽
Technical specifications NIP, kg101 Discreteness, g5/(2)* External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g500 Accuracy class according to GOST OIML R 76-1-2011II high Limits of error allowed during initial verification, goth 500g to 50 kg incl. ±5.0; sv.50kg to 52kg incl. ±10.0 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 40kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Mine vacuum furnace SNVS-6.5/12.5- I4
Mine vacuum furnace SNVS-6.5/12.5- I4
High-temperature furnaces are capable of heating materials up to 1700 degrees. The scope of their application covers the heat treatment of various materials in an inert medium or vacuum. TULA-TERM furnaces are used for heat treatment of plastics, ceramics, metals, alloys, lacquers and other materials. The equipment allows sintering, annealing, soldering, quenching, drying, burning and molding. In industry, our installations are most often used for quenching parts and sintering hard alloys.
Produced in: Tula
Electric cabinet vacuum drying SNVS-5,05.4,65.4,90/2-I2/2KV
Electric cabinet vacuum drying SNVS-5,05.4,65.4,90/2-I2/2KV
The electric vacuum drying cabinet SNVS-5,05.4,65.4,90/2-I2/2 KV is designed for drying and setting selected stages (up to 20 in each program) of the vacuum depth with automatic maintenance of the set value and automatic nitrogen (inert gas) supply to the chamber.
Produced in: Tula
VEGA
VEGA
The ultimate display quality is ensured by the use of built-in acoustic and vibration isolation, thermal stabilization, the industry's best sensitivity of the optical recording system and the unique design of the scanning probe system, which allows achieving atomic resolution in routine measurements. In the basic configuration, 50+ AFM techniques are available, including the HybriD method, which allows conducting all cutting-edge nanomechanical, electrical and magnetic studies. Intelligent ScanTronic™ algorithm for one-click optimization of scanning parameters, which allows for perfect relief measurements using the amplitude-modulation method, regardless of the operator's experience. Automated examination of multiple samples using a simple user interface to create a point-by-point scanning scenario and a database for stored received images. Control of samples with dimensions up to 200×200 mm and thickness up to 40 mm at any point of the surface with a positioning accuracy of 1 micron. Wide customization possibilities: installation of additional optical equipment, development of specialized sample holders, combination with a transport system, automation of measurements and data analysis in accordance with customer requirements.
Produced in: Moscow, Zelenograd
Power supply B5-89, B5-89/1
Power supply B5-89, B5-89/1
Technical specifications: Indicator name, unit of measurement, Indicator value, B5-89, B5-89/1 The range of the output voltage setting, the limits of the absolute error of the output voltage setting:- basic error, In; - in operating conditions, In, from 0 to 30.0 ± 0.2± 0.3, from 0 to 100.0 ± 0.3± 0.45 The range of the output current setting, the limits of the absolute error of the output current setting:- basic error, A; - in operating conditions, A, from 0 to 10.0 ± 0.2± 0.3, from 0 to 3.0 ± 0.1± 0.15 Instability of the output voltage when the supply voltage changes by ± 10% of the nominal value in the voltage stabilization mode, %, ± 0.05, no more, Instability of the output current when the supply voltage changes by ± 10% of the nominal value in the current stabilization mode, %, ± 0.2, no more, Instability of the output voltage when the load current changes at the output terminals of power supplies in voltage stabilization mode, %, ± 1, no more, Instability of the output current when the load voltage changes in the current stabilization mode at minimum load currents, %, ± 5, no more, Instability of the output current when the load voltage changes in the current stabilization mode at maximum load currents, %, ± 0.5, no more, Output voltage ripple in voltage stabilization mode, mV, 1.0, no more, Output current ripple in current stabilization mode, %, 1, no more, Instability of the output voltage from time, V, ± 0.5, ± 1.0 Instability of the output current from time, A, ± 0.3, ± 0.2 AC power supply: - voltage, V; - frequency, Hz, 230 ± 2350 ± 0.5, Weight, kg, 13.0, no more, Overall dimensions, mm, 384x301x169
MNIPI
Minsk
Produced in: Belarus, Minsk
Metrological high-voltage laboratory of TECHNOAS
Metrological high-voltage laboratory of TECHNOAS
For primary and periodic verification and calibration at the field of operation of the following measuring instruments that are part of automated information and measurement systems for commercial accounting of electrical energy (AIIS KUE) or non-automated metering units: • – Measuring voltage transformers (TN) of accuracy classes 0.2 and less accurate at loads normalized by GOST, and at real loads at the metering unit. • – Measuring current transformers (TT) of accuracy classes 0.2S and less accurate with nominal primary currents of 100...5000 A (including high-voltage transformers for 330 kV lines) at loads standardized by GOST 7746-2001 and at real loads; single-phase and three-phase electric active and reactive energy meters of accuracy classes 0.2S and less accurate. • – Auxiliary SI: ammeters, voltmeters, wattmeters, voltage, current and power converters, accuracy classes 0.2 and less accurate, phase meters, power factor meters of accuracy classes from 0.10 and less accurate. • – Energy frequency meters of accuracy classes from 0.02 and less accurate, used at the electricity metering unit. • – For measuring the load capacity of TN iTT. • – For measuring voltage losses in secondary TN circuits. – For measuring the quality of electrical energy (PCE) in accordance with the requirements of GOST 13109-97.
Produced in: Kolomna, Moscow region