Frequency meters H3-88
Frequency meters H3-88
Designed for measuring the frequency and period of sinusoidal and pulse signals, measuring pulse duration, time intervals, pulse duty cycle, frequency ratio of electrical signals, counting the number of pulses, output of reference frequency signals. Technical specifications: Input to (sinusoidal signal) - range 100 - 2500 MHz Input A, C (sine, pulse) - range 0.01 - 200 MHz Counting time: input A, C – 1, 10, 102, 103, 104 ms; login to – (16•1), (16•10), (16•102), (16•103), (16•104) ms The number of averages. the period of the. vx. signal - 1, 10, 102, 103, 104 Timestamp period – 10-7, 10-6, 10-5, 10-4, 10-3 Borehole measurement at inputs A, C – 1.000001- 999999999 Frequency ratio in channels: A/S and C/A - 0.0001- 999999999; B/S - 0.5 – 999999999 Quartz thermostatic generator The nominal frequency value is 5 MHz Error: ± 5•10-8 - for 30 days, ± 10-7 - for 12 months 9 decimal places Overall dimensions (HXHL) - 285x106x345 mm Weight: 4 kg Reference generator: 1x10-7 for 12 months. Operating conditions: - 10° C ... +50° C
MNIPI
Minsk
Produced in: Belarus, Minsk
The complex for monitoring temperatures and other physical quantities with SMS notification
The complex for monitoring temperatures and other physical quantities with SMS notification
The complex for monitoring temperatures and other physical quantities allows you to receive timely and reliable information about the object at each level of production. Currently the task of improving the production management process is becoming more and more urgent for industrial enterprises. It is especially important to solve this problem for those enterprises or their parts where the state of production parameters decisively affects the quality of products, and in some cases, the life and health of the consumer (for example, in the food industry or in the production of pharmacological preparations for their transportation). Taking into account the constant struggle for cost reduction, economic efficiency of production and competitiveness of products, it is necessary to ensure the correctness of management decisions and their adequacy to the current state of the process.
Produced in: Kolomna, Moscow region
MKS‑AT6101DR SPECTROMETER
MKS‑AT6101DR SPECTROMETER
- Measurement of pollution density and specific activity of radionuclides 134Cs and 137Cs in soils and soils; - Measurement of the specific activity of radionuclides 137Cs, 134Cs, 131I in water, food, forestry products, agro-industrial complex and liquid radioactive waste; - Determination of the content of natural radionuclides 40K, 226Ra, 232Th; - Identification of radionuclides: 134Cs, 137Cs, 131I, 40K, 226Ra, 232Th; - Measurement of the ambient dose equivalent of gamma radiation Measurements without sampling with GPS-binding Intelligent detection unit in an airtight container Automatic determination of the thickness of the contaminated soil layer by radionuclides 137Cs and 134Cs
Produced in: Belarus, Minsk
Surface smart probe  L=150 mm SZPV.150P with built-in flash memory
Surface smart probe L=150 mm SZPV.150P with built-in flash memory
from 13 524 ₽
Surface smart probe L=150 mm SZPV.The 150P with built-in flash memory is designed to measure the temperature of various materials by directly contacting the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor based on the Android program. Operating conditions of the SZPV.150P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPV.150P smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor based on the Android program. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor based on the Android program. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Calibration capability.
Produced in: Kolomna, Moscow region
Laboratory electronic thermometer LTA-M
Laboratory electronic thermometer LTA-M
The error is ±0.2 °C in the range of -196...+300 °C. The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Multifunctional UKRV-2 air flowmeter
Multifunctional UKRV-2 air flowmeter
Purpose: measurement of the volume of air pumped through the analytical filter; measurement of volumetric air flow through an analytical filter. Features: output of information to the LCD indicator; automatic and manual control of an external actuator (valve, crane); obtaining information about the analytical filter used using a barcode reader; transmission of data on the state of the device, the measured volume flow and the pumped volume of air to communication channels; providing access to information via the RS-485 interface; work both independently and as part of radiation monitoring systems
Doza
Zelenograd
Produced in: Moscow
Smart submersible probe  L=300 mm SZPG.300P with built-in flash memory A
Smart submersible probe L=300 mm SZPG.300P with built-in flash memory A
from 12 627 ₽
The smart submersible probe L=300 mm SZPG.300P with built-in flash memory is designed to measure the temperature of various materials by directly contacting the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPG.300P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPG.300P smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect external power. Possibility of calibration.
Produced in: Kolomna, Moscow region
CHEMICAL EXHAUST CABINET MODELS: LK-900, LK-1200, LK-1500, LK-1800 (all with a high-voltage fuse)
CHEMICAL EXHAUST CABINET MODELS: LK-900, LK-1200, LK-1500, LK-1800 (all with a high-voltage fuse)
from 169 790 ₽
1. LK-900 with a high-voltage fuse Width - 960 GRANTEC - 133 610 ₽ LAB HPL- 136 840 ₽ POLYPROPYLENE - 127 470 ₽ 2.LK-1200 with a high-voltage fuse Width - 1260 GRANTEC - 153 570 ₽ LAB HPL- 157 460 ₽ POLYPROPYLENE - 145 000 ₽ 3.LK-1500 with a high-voltage fuse Width - 1560 GRANTEC - 176 510 ₽ LAB HPL- 181 130 ₽ POLYPROPYLENE - 165 550 ₽ 4.LK-1800 with a high-voltage fuse Width - 1860 GRANTEC - 197 670 ₽ 202 970 ₽LAB HPL- 136 840 ₽ POLYPROPYLENE - 184 290 ₽
SpetsBaltMebel
г. Санкт- Петербург
Produced in: Saint Petersburg
Digital oscilloscope C8-43
Digital oscilloscope C8-43
It is designed to study periodic signals in the frequency band 0-50 MHz and single electrical signals by registering them in digital memory with a sampling frequency of up to 50 MHz, observing their shape on a liquid crystal display (LCD), measuring the amplitude and time parameters of the signal under study. Description: 2 mV...10 V/div; 10 ns...100 s/del ADC: 2 channels, 100 MHz, 8 bits, 64 KB/channel Equivalent sampling rate of 10 GHz Marker measurements U: ±2.5%,T: ±1.5% Pre-start, averaging,filtering Familiar management interface High-quality, "live" image Additional modes in the "MENU" Low price Screen 80x100 mm (CRT made in Holland) Dimensions, weight: 120x300x380 mm, 7 kg Power supply: ~220V, 80 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
UNIVERSAL EXHAUST HOOD DEMONSTRATION MODELS: LK-900, LK-1200, LK-1500
UNIVERSAL EXHAUST HOOD DEMONSTRATION MODELS: LK-900, LK-1200, LK-1500
from 114 060 ₽
1. LK-1500 SMS-D (case - chipboard) Width - 1500 Ceramics - 91 230 ₽ GRANTEC- 99 320 ₽ 2. LK-1500 SMS-D (case - polypropylene) Width - 1500 Ceramics - 102 100 ₽ GRANTEC- 115 980 ₽ 3. LK-1500 SMS-D (case - steel) Width - 1500 Ceramics - 113 920 ₽ GRANTEC- 131 500 ₽
SpetsBaltMebel
г. Санкт- Петербург
Produced in: Saint Petersburg
Electromagnetic flow meter Volga EM
Electromagnetic flow meter Volga EM
from 300 000 ₽
The Volga EM electromagnetic flowmeter is designed to measure the volumetric flow rate of drinking, natural, purified and waste water in pressure and non-pressure water pipelines. The device is designed specifically for use as part of commercial metering units and meets all the requirements for measuring equipment used for financial settlements of economic entities. The flow meter can be equipped with connecting fittings that allow the measuring sensor to be installed in a water duct with a non-pressure flow mode, for example, in a sewer collector (the so-called "L-system"). Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters PP – full-pass primary converter PPM is a full–pass primary converter for low costs and installation in L-systems BP – mortise rod primary converter Pipe sizes Du, mm: 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300 mm
Produced in: Moscow