Equipment

2278 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 392
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2278 products
Nitrogen generator GA-600
Nitrogen generator GA-600
from 444 000 ₽
The nitrogen generator is designed to create an inert atmosphere, fill low-pressure tanks, "wash" test tubes with inert gas and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. Technical specifications Volume fraction of nitrogen is not less than 99.5 % by volume (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than 0.5 % vol. Volume fraction of water vapor is not more than 0.002 % vol. (20 ppm) Maximum nitrogen capacity: at an inlet air pressure of 8 ati is at least 600 l/h (10 l/min) at an inlet air pressure of 6 ati is at least 480 l/h (8 l/min) The time of setting the operating mode for single-shift operation is no more than 30 min Nominal inlet air pressure is 8 ati Maximum allowable inlet air pressure is 8.5 ati Minimum inlet air pressure is 7.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 3600 l/hour (60 l/min) Overall dimensions, (width x depth x height) are not more than 230x580x680 mm Weight is not more than 32 kg Working conditions: ambient temperature, C°, is from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Modular liquid cooling unit VCHV-300
Modular liquid cooling unit VCHV-300
Cooling capacity at water temperature = +20C, output.water=+15C, Current.cp.=+30C, 300 kW
Produced in: Tula
Collection for storage of purified water S-240
Collection for storage of purified water S-240
from 97 000 ₽
Designed for collecting, storing and distributing purified water obtained by various purification methods, with a capacity of 240 liters and 100% stainless steel, which allowed for a long service life. Dimensions in terms of 690x660 mm Weight 24 kg
Livam
Belgorod
Produced in: Belgorod
Optical Transceiver 1x9 OC3/STM1/Fast Ethernet (155Mbps)
Optical Transceiver 1x9 OC3/STM1/Fast Ethernet (155Mbps)
Optical transceivers are available in 9-pin plastic cases with separate optical input/output for SC (FC) connectors
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Liquid low-temperature thermostat CRYO-MT-17
Liquid low-temperature thermostat CRYO-MT-17
The operating temperature range is -30...+105 °C. Bath volume 22 l Overall dimensions 400x675x830 mm The open part of the bath is 130x162 mm Bath depth 500 mm Weight 57 kg Power consumption 3.5 kW
Produced in: Tomsk
Laboratory shaft furnace SSHOL-3/11-KP
Laboratory shaft furnace SSHOL-3/11-KP
Designation SSHOL-3/11-KP Temperature, oC 1100 Supply voltage, 220 V Power, kW 5 The amount of working space, l 2.2
Produced in: Tula
Leakage detector with the function of diagnosing shut-off valves Success AT-407ND
Leakage detector with the function of diagnosing shut-off valves Success AT-407ND
from 122 820 ₽
The leakage detector with the function of diagnosing shut-off valves "Success AT-407ND" is designed to detect places of depressurization of underground pipelines of heat, water, gas, oil supply systems at a depth of up to 3 m in channel and without channel laying. The search for damage sites is carried out by the acoustic method. The kit includes a set of "ADM-227", consisting of a small-sized acoustic sensor with a magnetic base and an extension pin. The presence of the ADM-227 kit in the leak detector makes it possible to carry out work on leak detection and monitoring the condition of shut-off valves, both on metal and plastic pipes of small diameter. The leak detector allows you to detect violations of the tightness of the shut-off valves. If the sealing of the shut-off element is violated, the product (liquid or gas) leaks. Characteristic acoustic leakage noises are detected by the high-quality microphone of the sensor kit "ADM-227".
Produced in: Kolomna, Moscow region
CRYO-VT-05-02 Low-temperature liquid thermostat
CRYO-VT-05-02 Low-temperature liquid thermostat
It is designed to maintain the set temperature of the coolant circulating in the internal bath of the thermostat and in the connected external consumers. Feed pump for external closed-type thermostating systems. Cooling power 200 W at -80 °C. An internal bath with a volume of 15 liters and a depth of 250 mm. The operating temperature range is -80...+20 °C. Overall dimensions 800x500x1220 mm The open part of the bath is 125x190 mm Bath depth 250 mm Weight 119 kg Power consumption 4.2 kW.
Produced in: Tomsk
Laboratory mercury analyzer "RA-915Lab"
Laboratory mercury analyzer "RA-915Lab"
1 supp.
Technical specifications: Measuring range 0.5–500 ng Sample dispenser capacity 5000 mg / 2800 ml Analysis time 1-5 min Operating temperature range with software control 50-950 °C with software control The capacity of the autosampler is 45 samples Power supply 220 ± 22 V, 50 ± 1 Hz Dimensions (LxWxH), no more: with autosampler without autosampler 450x840x460 mm 450x490x460 mm Weight, no more: with autosampler without autosampler 57 kg 40 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
2VVN1-3M Water ring vacuum pump
2VVN1-3M Water ring vacuum pump
The working fluid of the pump is water. These pumps are designed to work with liquids as well as gases and vapors slightly soluble in them that are not aggressive to the materials of the 2VVN1-3M pump design, not explosive and non-toxic. The use of a 2VVN1-3M(H) water-ring vacuum pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the electric motor and destruction of the working bodies of the 2VVN1-3M(H) pump. The vacuum water ring pump 2VVN1-3M (H) is manufactured in the climatic version of UHL (i.e. for moderate and cold climate) 4 and O4 according to the GOST standard 15150-69, meets the requirements of technical specifications TU 3648-015-00218526-2000, designed and manufactured taking into account the requirements of GOST R 52615-2006. Electricity grid must meet the requrimemnts of GOST 32144-2013
Produced in: Kazan
Circulation thermostat LT-116a
Circulation thermostat LT-116a
The LOIP LT-116a modification device consists of an immersion thermostat-circulator LOIP LT-100 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +100 with tap water cooling °C Tvods+5 ... +100 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 1900 Pump: max. flow rate, l/min 7.5 pressure, bar 0.17 Bath volume, l 16 The working fluid is water, water-glycerin mixture. The open part of the bath / depth, mm 190x296/200 Overall dimensions, mm 355x335x420 Weight, kg 11.5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Magnetic Stirrer RITM
Magnetic Stirrer RITM
1 supp.
Technical specifications Supply voltage, V 220 Rated network frequency, Hz 50 Rotation speed range, rpm 300-1500 Overall dimensions, diameter/height, mm 125/50 Weight, kg 0,5 Stirrer housing Polypropylene Stirrer surface (chemically resistant material) Polypropylene Mixing volume, max, l 1 Operating conditions Ambient air temperature, °C 5 … 40 Relative humidity at 25 °C, % up to 90 Atmospheric pressure, kPa/mmHg. 84,0 … 106.7/ 630 … 800
Econix-Expert
Москва
Produced in: Moscow