Portable microscope SIAMS MAP-5
Portable microscope SIAMS MAP-5
● Magnification range: 50 - 800x ● Interchangeable lenses planachromat 5x/0.12, 10x/0.25, 20x/0.40, 40x/0.60 (on request), 50x/0.70, 80x/0.80 with extended working range ● Eyepiece 10x/18mm ● Illuminator: LED illuminator with stabilized source and built-in battery. Lighting adjustment with linear intensity change. The charger is included. ● Microscope tripod with height adjustment with a stroke of 35 mm. The ability to tilt the tripod at an angle of ± 20 degrees forward and backward to take pictures of a curved surface without moving the microscope from the mounting point ● Moving the lens 30x30 mm along the X-Y axes ● Coarse and fine focusing handles ● Strong magnetic fastening on 3 points using hinged supports for mounting on curved convex and concave steel surfaces, including pipe bends with a diameter of 60 mm ● Anti-slip nozzles ● Metal mounting for non-magnetic surfaces with ratchet mechanism ● The base for fixing the microscope in stationary operation ● Bayonet mount for camera ● C-mount mount for video camera ● Transport plug for video output ● A case for carrying a microscope with a camera.
SIAMS
Екатеринбург
Produced in: Ekaterinburg
Pilot fermenter 15-50 L for pharmaceuticals
Pilot fermenter 15-50 L for pharmaceuticals
Biotechno pilot fermenters have a fully aseptic design and are easily validated. The universal C-Bio control system, unified for fermenters of any volume, greatly simplifies the scaling process and allows you to transfer fermentation data to larger fermenters. The total volume is 15-50 liters Working volume 10.5-35.0 l Material of manufacture: 316L stainless steel (for parts in contact with the product) Stainless steel grade 304L (for parts not in contact with the product) Design pressure 3.0 kg/cm3 (capacity) 4.0 kg/cm3 (jacket) Design temperature 143°C (capacity) 151°C (shirt) Surface treatment Internal polishing 0.4 µm + electropolishing External polishing 1.2 µm Ports on capacity Upper Port for diaphragm pressure gauge Port for diaphragm pressure transmitter Bursting membrane Exhaust gas outlet and condenser Inoculation Viewing window Foam sensor port Nozzle for CIP Spare port Upper side walls Air supply Viewing window Culture liquid supply x 3 Ring Bubbler Spare port Lower side walls Port for PT100 temperature resistor sensor Port for pH sensor Port for dissolved oxygen sensor Spare port Sampling port Shirt Steam supply / outlet of the cooled water Steam output / Cold water supply (including safety valve and pressure gauge) Low drain valve 2. Mixing mechanism Top drive with single mechanical seal 0.25 kW DC motor Speed 30-600 rpm (inverter control) Val – F20 Adjustable three-level paddle stirrers 3 welded partitions 3. Aeration mechanism Automatic air supply 2 VVM 5" high-efficiency 0.2 µm filter and 316L stainless steel filter housing Automatic Air flow meter 4. Pressure mechanism The bursting disc Pressure gauge Positioner Pressure sensor Pressure control valve 5. pH/DO control mechanism pH sensor pH Sensor Holder Cable for pH sensor DO sensor DO Sensor Holder Cable for the DO sensor Peristaltic pump (fixed 20 rpm) x 2 Bottle 1 l x 2 6. Defoaming mechanism Defoaming sensor Cable for defoaming sensor Peristaltic pump (fixed 20 rpm) x 1 1 L x 1 bottle 7. Temperature control mechanism Temperature sensor (PT 100) Heat exchanger Pump 8. Strapping and frame Support Corners and channels – STS304 Manufactured strapping Air supply Supply of process steam Supply of pure steam Cooling water supply Return of cooling water Drain of waste water Drain of waste liquids Exhaust gas output Instrumentation Diaphragm valve Direct flow valve Steam trap Membrane pressure gauge Ball valve and pneumatic angle valve Check valve Safety valve Crankshaft, tee Welding of pipes Orbital welding (line in contact with the product) Manual welding (common line)
Produced in: Moscow
Mains current indicator autonomous “STORK” EI3008
Mains current indicator autonomous “STORK” EI3008
Technical specifications The indicator provides the ability to measure current without breaking circuits at a height of up to 7.5 m from ground level. Power supply: two AAA elements of 1.5 V. Operating conditions: temperature from -10°C to +40°C, relative humidity 80% at +25 °C. Overall dimensions in the working position 6600x70x80 mm Overall dimensions in the stowed position (cover) 1700x100x70mm. Weight 2.5 g. As a measuring device, a digital multimeter with a memory function, semi-automatic selection of measurement limits is used. Measurement of alternating current up to 500 A with a measurement accuracy of 3%. Measurement of AC and DC voltage up to 600 V with a measurement accuracy of 2%; resistance measurement – up to 2.0 M ohms. Ringing of electrical circuits. Structurally, the indicator consists of four fiberglass rods articulated with each other using connectors. On the upper rod there is a detachable magnetic circuit covering the wire in which the current must be measured. On the lower rod there is a measuring device that records the current values. They are not subject to mandatory certification (they are not included in the “Nomenclature of products and services (works) for which mandatory certification is provided by legislative acts of the Russian Federation”. It was put into effect from 01.12.2002 by the resolution of the State Standard of the Russian Federation No. 64 dated 30.07.2002.)
Produced in: Krasnodar
Nitrogen traps
Nitrogen traps
Nitrogen traps are designed for use in various vacuum systems in order to prevent the ingress of vapor gases and various organic compounds from high-vacuum and pre-vacuum pumps into the vacuum chamber (system) following in the reverse flow, as well as to protect vacuum units from organic substances present in the vacuum volume.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Non-standard vacuum testing equipment
Non-standard vacuum testing equipment
For scientific and industrial applications.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Liquid thermostat ZM1004
Liquid thermostat ZM1004
Technical specifications the maximum temperature value in the thermostat is 95 °C. the range of water heating is from the current temperature to 95 ° C. The accuracy of automatic temperature maintenance is 0.5 °C. power supply parameters at which technical characteristics are normalized: type of current – alternating single-phase; voltage , V — 220±22; AC frequency , Hz — 50 ±1; the power consumption when entering the mode should be no more than, kVA — 4; the power consumption while maintaining the temperature should be no more than, kVA - 2. Operating conditions: ambient temperature – from plus 10 to plus 35 ° C.; relative humidity, from 65 to 80%. the electrical insulation resistance between the electrical circuits and the housing at ambient temperature (20 ± 5) ° C and relative humidity (80 ± 3)% is not less than 20 mOhm. electrical insulation between the electrical circuits and the housing under the conditions of clause 2.8. must withstand an AC voltage of 1.5 kV sinusoidal frequency of 50 Hz. overall dimensions not more than, mm: 520x420x480. tank volume – 40 liters. the average service life is at least 10 years. the weight of the thermostat is not more than 26 kg.
Produced in: Krasnodar
Helium mass-spectrometric leak detector TI1-50M “HeliTest” from NPO “Helikon”
Helium mass-spectrometric leak detector TI1-50M “HeliTest” from NPO “Helikon”
The helium leak detector TI1-50M is a universal highly sensitive device designed to test the tightness of various systems and objects that allow pumping out the internal cavity, as well as those filled with helium or a mixture containing helium, and detect (localize) places of leakage (leaks). Specifications: Measuring range at the leak detector inlet, Pa•m3/s from 5•10-13 to 1•10-5; Range of indications when working by probe method, Pa•m3/s from 1•10-9 to 1•10-5; Time to enter the readiness mode for measurements, no more than, min 5; AC supply voltage, V, Hz 220±10%, 50±1; Power consumption, VA 1200; Overall dimensions (WxHxD), no more than, mm 480x470x390; Weight, no more than, kg 40; Average time to metrological failure, h 15000;
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Spreading cone KR-1
Spreading cone KR-1
Device indicators: — minimum diameter of a concentric circle, mm — ( 72 ); — maximum diameter of a concentric circle, mm — ( 250 ); — the distance between the circles of the cone, mm — ( 5 ); — height of the sampling cone, mm — ( 60 ); — upper inner diameter of the sampling cone, mm — ( 37 ); — lower inner diameter of the sampling cone, mm — ( 70 ); — measurement error, mm — ( +2.5 ); — overall dimensions of the cone, mm — ( 280x120 ); — the mass of the cone, kg — ( 4 ).
Produced in: Krasnodar
Halogen leak detector "GTI-8"
Halogen leak detector "GTI-8"
It is designed to search for leaks of freons and other halogen-containing gases, for example, gas, in working equipment, and when testing systems, including cable ones, for tightness. The GTI-8 halogen leak detector also allows detecting an increase in the concentration of such gases in the room or near the controlled object. Technical characteristics of the leak detector "GTI-8" Parameter Sensitivity of the leak detector GTI-8, m3 Pa/sec., not less 1.0 - 5.3/10e-7 Time constant, sec., no more 3 Compensation of the initial sensor current Availability Automatic background signal compensation Availability Adjustable trigger threshold Availability Food ~220V, 50Hz (14.8V for GTI-8B) For modification of GTI-8B, continuous operation time, hour, at least 8 Operating mode setting time, min, no more 5
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
The ”SEARCH" indicator EI3007
The ”SEARCH" indicator EI3007
Technical specifications Provides detection of a live wire located at a distance of up to 1m (with maximum sensitivity). The detection accuracy is ± 2.5 cm (with minimal sensitivity). The location of the wire is marked by a light and sound signal. A 45-65 Hz bandpass filter is included in the circuit, which provides a more accurate finding of the hidden (masked) wire. The “Crown” battery is used as a power source. Operating conditions: temperature from - 10oC to +45oC, relative humidity 80% at +25oC. Overall dimensions — 205x47x20 mm, weight — 0.15 kg. They are not subject to mandatory certification (they are not included in the “Nomenclature of products and services (works) for which mandatory certification is provided by legislative acts of the Russian Federation”. It was put into effect from 01.12.2002 by the resolution of the State Standard of the Russian Federation No. 64 dated 30.07.2002.). TU 224-023-05766445-98.
Produced in: Krasnodar
Pneumostends / Pneumopults
Pneumostends / Pneumopults
For filling products with test gas (helium) or a mixture of gases. The main application of the products are leakproofness control tests by the mass spectrometric method according to OST 92-1527 and other types of tests. Areas of work: Development of complete 3D models of stands, Development of RCD stands in accordance with GOST and ESKD; Manufacture of pneumatic stands and their components; Installation and commissioning; Development of automated process control systems taking into account the Leak Control Technology; Development of on-line systems for recording the condition of equipment and technological process with automation of the product testing process.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Halogen leak detector MGTI-1
Halogen leak detector MGTI-1
It is necessary to search for leaks of freons and other halogen-containing gases, for example, gas, in working equipment, and when testing systems, including cable ones, for tightness.
NPO "Gelikon"
Saint Petersburg