Equipment

2245 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 389
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2245 products
Explosion-proof vacuum electric furnace START-25
Explosion-proof vacuum electric furnace START-25
Vacuum resistance furnaces are necessary for heating products before pressure treatment, for sintering, degassing, quenching, annealing, soldering and chemical-technological processes. Such furnaces among all the variety of thermal equipment are considered the most environmentally friendly – heat treatment is carried out at t up to +2500 ° C in a purified vacuum. Under certain conditions, vacuum furnaces are used to work with neutral gases. The outer part of the furnace is made of stainless steel and is cooled by liquid. The inner part of the working chamber, where the heat treatment of materials is carried out, is made of an alloy of molybdenum and tungsten. The components are characterized by a low inertia force, reduced gas separation. The settings are available on the control panel, where the instruments, automatic and manual control switches are located. At every enterprise of the electronic industry, nuclear power, an explosion-proof vacuum resistance furnace is needed. The same applies to areas where various products undergo heat treatment at the stage of production and preparation for use.
Produced in: Tula
Furnace for heating in a protective environment CHO (3)-6/11
Furnace for heating in a protective environment CHO (3)-6/11
from 1 420 750 ₽
Designation SNO(H)-6/11 Power, kW, no more than 8 Supply network voltage, V 380 Frequency, Hz 50
Produced in: Tula
VL-220M comparator scales
VL-220M comparator scales
from 274 990 ₽
Technical specifications NIP, g82/220 Discreteness, g0,00001/0,0001 Self-calibration Diameter of the scale bowl, mm80 The smallest weighing limit, g0,001 The price of the calibration scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.001g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 220g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * from 1mg to 10mg ± 0.2; from 10mg to 82g ± 0.1; sv. 82g ± 0.3 The setting time, seconds, no more - fast mode - 8/3; - standard mode - 10/6 Overall dimensions of the scales (LxWxH), mm356x220x338 7 years warranty Weight of the scales, kg, not more than 7.6 The weight adjustment is built-in
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Automatic Rapid Analysis device for turbidity/solidification temperature of petroleum products TPZ-LAB-12
Automatic Rapid Analysis device for turbidity/solidification temperature of petroleum products TPZ-LAB-12
TPZ-LAB-12 belongs to the latest generation of equipment of JSC "LOIP". The device is designed taking into account all the requirements of the standards for testing. A unique feature of TPZ-LAB-12 is a built–in cooling unit capable of cooling the test cell to -85 °C without the use of external cooling systems. The device automatically sets and maintains the temperature of the cooling bath, conducts tests to determine the temperature of turbidity and solidification, creates and stores test reports in memory. Technical specifications: The volume of the analyzed sample is 4.5 ml Temperature range of the test cell -85...+51°C Accuracy of temperature maintenance ± 0.5 °C Maintaining the temperature of the cooling bath Integrated cooling system Built-in memory of at least 1000 protocols Color LCD display with touch screen Supply voltage 220 V Power consumption 250 W Overall dimensions 315x470x405 mm Weight 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
NVDM-160 High-vacuum Diffusion Pump
NVDM-160 High-vacuum Diffusion Pump
The operation of the NVDM-160 diffusion pump is based on the capture and transfer of the pumped gas by a steam jet flowing from the slit gaps of the steam line nozzles towards the outlet flange. The oil reflector of the NVDM-160 diffusion pump is a flange with a cooling tube passing through it, soldered to a cap located in the center of the flange. The NVDM-160 closed-type diffusion pump heater consists of tubular electric heaters fixed in the heater housing. During the operation of the pump, it is necessary to monitor the flow rate and temperature of the cooling water, the level of the working fluid and its temperature. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium. Therefore, the time after which the working fluid is replaced or refilled can be from 100 to 1000 or more hours. A large flow rate of the working fluid is observed when the pump is operating in the range of inlet pressures from 6.6×10-2 to 13.3 Pa (from 5×10-4 to 1×10-1 mm Hg). Water at the inlet to the cooling systems of the housing and oil reflector must be supplied with a pressure of no more than 0.5 MPa (5 kgf / cm2) and temperature from plus 40C to plus 250C. The recommended cooling water consumption is 60+10 l/h and is regulated by the outlet water temperature, which should not exceed plus 400C. The water drain should be free (with a jet break). Not allowed: operation of the pump without water cooling, exceeding the maximum exhaust pressure of 33.3 Pa (0.25 mm Hg). The level of the working fluid during operation, at which the parameters of the NVDM-160 pump are provided, must correspond to min 10mm, max 17mm. The volume of the filled working fluid is 0.3 liters
Produced in: Kazan
Laboratory drying cabinets SHS-20/3,0
Laboratory drying cabinets SHS-20/3,0
The electric drying cabinet SHS-20/3,0 is designed for drying, heating various materials in an air environment at a maximum temperature of 300 ° C. Technical specifications The electric cabinet operates at ambient temperature from 10 to 35 ° C and relative humidity up to 80% at 25 ° C. Operating temperature- 300 ⁰C Power consumption - 2000 W Dimensions of the working chamber WxDxH- 195x480x195 mm Dimensions WxDxH- 325x760x445 mm Weight - 30 kg
MIUS
Tula
Produced in: Tula
Circulation thermostat LT-424a
Circulation thermostat LT-424a
The LOIP LT-424a modification device consists of an immersion thermostat-circulator LOIP LT-400 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, l/min 6...12 pressure, 0.4 bar Bath volume, l 24 The working fluid is water, silicone oil. Open part of the bath / depth, mm 360x296/200 Overall dimensions, mm 532x335x400 Weight, kg 15.8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Orbital Shaker LOIP LS-211
Orbital Shaker LOIP LS-211
Technical specifications: Type of motion orbital Platform rotation speed, min-1 40-300 The amplitude of rotation of the platform, mm 30 Maximum load on the platform, kg 20 Timer (time is displayed in h, min, s) 0...8 hours Power consumption, W 200 Platform size, mm 445x305 Overall dimensions, mm 525x510x225 Weight, kg 37
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum drying cabinet with manual control SNVS-90/3.5
Vacuum drying cabinet with manual control SNVS-90/3.5
from 372 817 ₽
Drying cabinet with manual vacuum adjustment SNVS-90/3.5 (or SNVS-4,3.4,3.4.9/3,5) It is intended for heat treatment of materials at temperatures up to 350 ° C with air access and in a vacuum controlled by manual valves. Thanks to modern temperature control, it demonstrates excellent performance of heat treatment modes. The measurement system complies with Russian standards and has certificates of entry into the SI State Register. Design for heat treatment in production and clean laboratories.
Produced in: Tula
Vacuum drying cabinet SNVS-145/5
Vacuum drying cabinet SNVS-145/5
They are designed for carrying out various technological processes at temperatures from 40 to 500 oC, in vacuum up to 1x10−3 mmHg, or in an inert gas of high purity. They are used for drying, light annealing, aging, low and medium tempering in an oxidizing environment, degassing of ferrous and non-ferrous metals (including copper and copper alloys), or any other materials processed under similar conditions. The program setting of heat treatment modes including vacuuming, high purity inert gas intake with repeated vacuuming allows heating in an oxidizing environment with high purity of the surfaces of the processed parts, without scale formation and oxidation.
Produced in: Tula
Chamber electric resistance furnace CHO-12.18.12
Chamber electric resistance furnace CHO-12.18.12
from 550 000 ₽
Designation: SNO-12.18.12 Temperature: 1200 Opendoors: electromechanical Camera size (w.G.V.):1200x1800x1200 Regulation zones: 1
Produced in: Tula
RADIATION PEDESTRIAN MONITOR MPP‑AT930
RADIATION PEDESTRIAN MONITOR MPP‑AT930
▪ Rapid adaptation to changes in the radiation background ▪ Audible and light alarms when gamma radiation is detected ▪ Mobility and the possibility of forming passages ▪ Self-control of components in the process of work ▪ The possibility of continuous or episodic radiation monitoring ▪ The possibility to work from a 230V, 50Hz network or from a built-in rechargeable battery Compliance with the international standard IEC 62244:2006 Stationary radiation monitors for the detection of radioactive and special nuclear materials at state borders
Produced in: Belarus, Minsk