Metrology

528 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 23
    Applying
    Loading...
  • 196
    Names
    Loading...
  • 54
    Manufacturer
    Loading...
  • 33
    Made in
    Loading...
  • 50
    Additional
    Loading...
View:
528 products
 Electronic Stopwatch-Meter IVPR-203M
Electronic Stopwatch-Meter IVPR-203M
from 40 940 ₽
The electronic stopwatch - time parameter meter IVPR-203M is a universal shield device of a new type for monitoring and measuring the time parameters of relays, switches and switches of electrical equipment, relay protection, automation and telemechanics.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Smart probe air high-precision L=150 mm CVV.150P with built-in flash memory
Smart probe air high-precision L=150 mm CVV.150P with built-in flash memory
from 11 400 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object Smart probe air high-precision L=150 mm CVV.The 150P with built-in flash memory is designed to measure the temperature of various materials by directly contacting the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor. The Android program is installed. Operating conditions of the SZVV.150P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe CVV.150P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor. The Android program is installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
BAS/BAS-1c Alarm Units
BAS/BAS-1c Alarm Units
Purpose: BAS: The unit is designed to provide light and sound signals under various conditions of controlled radiation conditions when connected to technical means that have a communication port with the unit (BOP, UDA-1AB, UDI-1B, UDG-1B, etc.). BAS-1c: The unit is designed to provide light and sound signals under various conditions of a controlled radiation environment, and operates under the control of an external device. The unit can be used in connection with individual technical means of radiation monitoring or as part of radiation monitoring systems and complexes, as well as with other compatible technical means that provide data exchange over communication lines organized on the basis of the RS-485 interface, using the DiBus exchange protocol (BOP-1M).
Doza
Zelenograd
Produced in: Moscow
Immitance meter E7-30
Immitance meter E7-30
Technical specifications: Wide frequency range 25 Hz–3 MHz Capacity (10-15-1) F Inductance (10-11-104) Gn Resistance (10-5-109) Ohms Conductivity (10-11-10) Cm Modulus of complex resistance (10-5-109) ohms Reactance (10-5-109) Om Phase shift angle -90° – +90° Q factor, loss factor 10-4-104 Leakage current (10-8-10-2) A The error is ±0.1% Offset voltage 0 – 40 V (external up to 120 V) Measuring signal level (0.005 – 1) V RS-232C, USB 2.0 interfaces Mathematical processing of measurements Dimensions, weight: 134x270x320 mm, 4 kg Power supply ~230 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Universal mobile complex for verification and repair of measuring instruments
Universal mobile complex for verification and repair of measuring instruments
The complex is equipped with air conditioning, heating and ventilation systems to create and maintain a set temperature level (20-25) ° C in the container body, at an outdoor temperature from minus 40 ° C to 40 ° C. Operating conditions Ambient air temperature from minus 40 to 40 ° C; Relative humidity up to 95 % at tº= 30 ° C; Atmospheric pressure from 84.0 to 106.7 kPa (from 630 to 800 mm Hg); General-purpose power supply: alternating three-phase current with a frequency of (50 ± 1) Hz with a RMS voltage value in each phase (380 ± 38) V. A set of functionally related working standards, special equipment and automation tools allows you to implement complex metrological maintenance of measuring instruments at automated (automated) and non-automated (RM) workplaces
Produced in: Moscow
Contact thermometer TK-5.09S with the function of measuring relative humidity
Contact thermometer TK-5.09S with the function of measuring relative humidity
from 11 400 ₽
The digital contact thermometer TK-5.09S is designed to measure the temperature of various materials, relative humidity by direct contact of the probe with the measuring object. The contact thermometer consists of an electronic unit and replaceable probes. Thermoelectric converters (TP) with NSH according to GOST R 8.585 are used as thermosensitive elements in the probes . Capacitive humidity sensors are used as a measuring element in the relative humidity probes.
Produced in: Moscow
DOSIMETER‑RADIOMETER ISS‑AT6130S
DOSIMETER‑RADIOMETER ISS‑AT6130S
A small-sized device for measuring the power of the ambient dose equivalent and the ambient dose equivalent of X-ray and gamma radiation. The case is made of impact-resistant ABS plastic Convenient menu Search mode
Produced in: Belarus, Minsk
Alpha-beta radiometer for measuring small activities UMF-2000
Alpha-beta radiometer for measuring small activities UMF-2000
A low-background alpha-beta radiometer with a silicon detector, widely used for measuring small activities. It is recommended for measuring the total alpha and beta activity of natural and drinking waters, as well as for measuring the activity of alpha-emitting radionuclides by spectrometric method. Purpose: measurement of the total activity of alpha-emitting nuclides in "thick" and "thin" counting samples of environmental objects; measurement of the total activity of beta-emitting nuclides in counting samples of soil samples, water samples, air filters and samples obtained by selective radiochemical extraction; measurement of alpha activity of nuclides in counting samples obtained after radiochemical preparation by radiometric method (if available); measurement of alpha activity of nuclides in counting samples obtained after radiochemical preparation by the spectrometric method (if there are techniques and a set of spectrometric "UMF - Spectrum").
Doza
Zelenograd
Produced in: Moscow
Portable Electrical Laboratory for testing and searching for cable damage by acoustic and induction method Athlete KAI-2.501
Portable Electrical Laboratory for testing and searching for cable damage by acoustic and induction method Athlete KAI-2.501
• Appointment Athlete KAI-2.501 o Search for a live cable. o Detection of the passage of hidden communications (metal pipelines, cable lines). o Preliminary detection of the distance to the place of damage. o Search for places of cable damage by acoustic method. o Search for places of cable damage by electromagnetic means. o Cable insulation test. o The presence of the "Friend-Foe" mode.
Produced in: Kolomna, Moscow region
Microphone condenser capsule M-101
Microphone condenser capsule M-101
It is designed to measure sound pressure in the air and is used in noise measuring equipment as a measuring transducer of infrasound, sound and ultrasonic pressure.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl