Pressure gauge MTIf-160
Pressure gauge MTIf-160
Pressure gauge with a range of measured pressure 0...160 kPa. Accuracy class 0.4 Connection size M20x1.5 mm Overall dimensions 160 mm Weight 1.5 kg
Produced in: Tomsk
ASKRO: Automated radiation monitoring system
ASKRO: Automated radiation monitoring system
The installations are designed for continuous monitoring of the radiation situation at specified points of radiation objects with data transmission via VHF radio frequency channel and/or GSM/GPRS network. Purpose: radiation monitoring of industrial sites of nuclear power plants and other radiation facilities (RCP); radiation monitoring of the environment of sanitary protection zones and observation zones (RCOS); creation of an automated system for monitoring the radiation situation (ASKRO) of territories, sanitary protection zones (SPZ) and monitoring zones (ZN) of radiation-hazardous objects; creation of situational crisis centers (SCC) of enterprises and regions.
Doza
Zelenograd
Produced in: Moscow
Laboratory electronic thermometer LTA-MF
Laboratory electronic thermometer LTA-MF
LTA-MF provides an error of ±0.2 °C in the measured temperature range from -196 to +200 °C The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Liquid low-temperature thermostat CRYO-VIS-T-07
Liquid low-temperature thermostat CRYO-VIS-T-07
Operating temperature range +10...+60 °C Five places for glass viscometers. The stability and uniformity of the temperature in the working bath is not worse than ± 0.01 ° C. Bath volume 20 l Overall dimensions 620x400x970 mm The open part of the bath is 240x170 mm Bath depth 300 mm The size of the viewing window is 205x260 mm Weight 60 kg Power consumption 3.5 kW
Produced in: Tomsk
Installation for measuring the volumetric activity of radioactive aerosols UDA-1AB
Installation for measuring the volumetric activity of radioactive aerosols UDA-1AB
Installation for continuous automatic monitoring of the concentration of radioactive aerosols in autonomous mode or as part of automatic radiation monitoring systems in the air of working rooms and ventilation systems. Purpose: measurement of the volumetric activity of alpha-emitting radionuclides and beta-emitting radionuclides contained in the form of aerosols in the air.
Doza
Zelenograd
Produced in: Moscow
DOSIMETERS‑RADIOMETERS ISS‑AT6130, ISS‑AT6130A, ISS‑AT6130D
DOSIMETERS‑RADIOMETERS ISS‑AT6130, ISS‑AT6130A, ISS‑AT6130D
Small-sized devices for measuring the power of the ambient dose equivalent and the ambient dose equivalent of X-ray and gamma radiation, as well as measuring the flux density of beta particles (AT6130). Durable metal case Convenient menu Selective measurement of beta and gamma radiation in mixed fields (AT6130) Measurement of dose rate up to 100 mSv/h (AT6130D) Search mode Headphones for working in noisy environments (on request)
Produced in: Belarus, Minsk
Infrared analyzer INFRASKAN 4200
Infrared analyzer INFRASKAN 4200
1 supp.
The INFRASKAN 4200 analyzer has been tested at the D.I. Mendeleev VNIIM, entered into the unified State Register of measuring instruments under No. 83050-21. All manufactured devices undergo primary verification and have the appropriate certificate. Analyzes a wide range of quality indicators (protein, moisture, quantity and quality of gluten (IDC), fat/oil content, water absorption capacity, acid number, peroxide number, m.d. phosphorizing substances, etc.) Is calibrated to assess moisture and protein in whole grains (wheat, barley). The cuvette compartment for the analysis of bulk, liquid and pasty products allows to analyse liquid vegetable oils without the use of additional devices. The built-in whiteness module allows to determine the whiteness of the product simultaneously with other quality indicators (moisture, protein, amount of gluten). A wide spectral range (400-2500nm) provides measurement of the zonal reflection coefficient to determine the whiteness of flour in accordance with the GOST 26361-2013 methodology. It is possible to calculate the amino acid composition of feed components. To organize the work of analyzers in the ECANET network, the INFRASCAN-4200 analyzer can be used as a server for storing and transmitting data. The remote access mode allows to remotely update existing calibrations, install additional calibration models and develop new calibration models for new products, as well as make adjustments to technical settings if necessary.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
EVRAZTEMP Submersible thermocouples for reusable use
EVRAZTEMP Submersible thermocouples for reusable use
Purpose: Measurement of molten metal temperature Scope of application: Induction furnaces, blast furnaces, casting ladles Measuring range: from 600°C to 1800°C Accuracy: 0 + 3°C at 1554°C Measurement time: 4 sec Tube Length: from 100 to 1800 mm (other lengths are available on request) Slag Cap: Steel, uncapped, aluminum Number of measurements: 5 or more times Type of NSH: B, S
Produced in: Lipetsk
Flow meter-sampler of radioactive gas-aerosol mixtures "BREEZE"
Flow meter-sampler of radioactive gas-aerosol mixtures "BREEZE"
Appointment: continuous pumping of atmospheric air with a constant flow rate through a filter element based on Petryanova fabric. measurement of ionizing radiation parameters at a controlled point in accordance with the capabilities of the unit used.
Doza
Zelenograd
Produced in: Moscow
Mobile laboratory of measuring equipment PLIT-A2-4/1M
Mobile laboratory of measuring equipment PLIT-A2-4/1M
The complex is equipped with air conditioning, heating and ventilation systems to create and maintain a preset temperature level (20 ...25) ° C in the van body, at an outdoor temperature from minus 40 ° C to 40 ° C. PLIT-A2-4/1M is equipped with a removable diesel electric unit with a capacity of 16 kW, which ensures the functioning of all systems in autonomous mode. A set of functionally related working standards, special equipment and automation tools allows you to implement comprehensive metrological maintenance of measuring instruments at workplaces
Produced in: Moscow
UNM-300/2000 portable magnetizing device
UNM-300/2000 portable magnetizing device
The principle of operation of the magnetic particle flaw detector: The device provides monitoring and detection of surface defects by the applied field method or by the residual magnetization method. The kit with the device includes power cables, remote solenoids, and an electromagnet, with which you can produce longitudinal or circular magnetization of the part. A trolley is provided for the transportation of technical equipment and the detection of defects in the field. Magnetization is carried out by alternating, direct or pulsed current of large magnitude, due to which high values of the magnetizing field strength are achieved. Features and advantages of the UNM-300/2000 magnetic powder control device: Microprocessor control, which allows you to memorize and accurately reproduce the desired modes and selected measurement parameters, as well as work as part of automated stands and control systems; The magnetizing device has a digital indicator on the front side and a control panel for selecting the operating mode, type and current strength; Automatic recognition of the type of connected external magnetizing device; Device temperature control and automatic shutdown in case of overheating; Remote connected magnetization devices allow you to control the quality of parts and assemblies of complex shape; Automatic demagnetization of controlled assemblies and parts; The equipment meets the requirements of the following standards: GOST R 56512-2015, GOST R 53700-2009 (ISO 9934-3:2002), GOST R 50.05.06-2018, GOST R ISO 10893-5-2016, GOST ISO 17638-2018, RD 34.17.102-88 and RD-13-05-2006; Devices of the MANUL series (UNM-300/2000 and others) are approved for use by the Russian Railways. Scope of application: Magnetic particle flaw detection is indispensable where quality control of various critical and loaded assemblies and parts is required, detection of surface defects that occur during their production, storage and operation. The device may be in demand: at factories for the production and repair of automotive, aviation and railway equipment, metro enterprises, military-industrial complex (inspection of shafts, axles, wheel pairs, pistons, beams, springs, etc.); in civil and military shipbuilding, elevator and crane enterprises (control of rigging equipment, hooks, etc.); at pipe rolling plants (determination of defects in rolled products); in the oil and gas, chemical industry (inspection of welds of equipment operating under pressure). The UNM-300/2000 portable magnetic particle flaw detector has a relatively small weight and dimensions, which allow it to be used as a stationary or portable device in specialized quality control laboratories or in ordinary workshops, garages, hangars, locomotive depots or warehouses. The UNM 300/2000 device, as well as other means of magnetic powder control, are normally used together with auxiliary equipment for the preparation and application of magnetic powder (suspension), for fixing the indicator pattern, magnetometers for determining residual magnetization, visual inspection means – magnifiers and endoscopes, as well as with ultraviolet irradiators in the case of fluorescent powders. Technical specifications Magnetization currents Variable, Pulse, Rectified (only for solenoid and electromagnet) The measurement error of the magnetization current is no more than 10%. characteristics of the pulse current The repetition frequency of unipolar current pulses during magnetization and of multipolar current pulses during demagnetization is (2 ± 0.2) Hz. The duration of the current pulses is at least 1.5 ms. Magnetic characteristics of the solenoid The maximum alternating magnetic field in the center of a single solenoid is at least 100 A/cm. The maximum alternating magnetic field on the axis in the center between two solenoids located at a distance of 200 mm is at least 60 A/cm. The maximum permanent magnetic field in the center of a single solenoid is at least 80 A/cm. The maximum permanent magnetic field on the axis in the center between two solenoids located at a distance of 200 mm is at least 50 A/cm. Values of magnetization currents The maximum alternating magnetization current in the unwound cable 6 m × 50 mm2 and on the electrical contacts is at least 1000 A. The maximum pulse magnetization current in an unwound cable of 4 m × 10 mm2 and on electrical contacts is at least 2000 A. The current adjustment range in the solenoids and the electromagnet is from 0.5 to 4.5 A. Characteristics of the electromagnet The maximum alternating magnetic field in the air gap of the electromagnet depending on the interpolar distance is as follows: - in the 140 mm gap: at least 75 A/cm; - in the 40 mm gap: at least 300 A/cm. The maximum constant magnetic field in the air gap of the electromagnet depending on the interpolar distance is as follows: - in the 140 mm gap: at least 100 A/cm; - in the 40 mm gap: at least 400 A/cm. Operating mode The operating mode is cyclic: magnetization/pause. The magnetization time is adjustable from 1 to 40 s. The demagnetization time is adjustable from 5 to 60 seconds. Demagnetization of details is performed automatically. The time of setting the operating mode is no more than 15 seconds. The duration of continuous operation is at least 8 hours. Power supply parameters The device is powered by an alternating current network with a voltage of 220 V and a frequency of 50 Hz. The power consumed from the network is no more than 5 kVA. weight and size characteristics Overall dimensions of the device (w × h × d) – no more than 267×245×465 mm. The weight of the device is not more than 50 kg. Other characteristics The average worktime before failure is at least 12500 hours. The average recovery time is no more than 6 hours. The average service life of the device is at least 10 years. Compliance with standards The device fully complies with the requirements of GOST R 56512-2015, GOST R 53700-2009 (ISO 9934-3:2002), GOST R 50.05.06-2018, GOST R ISO 10893-5-2016, GOST ISO 17638-2018, RD 34.17.102-88 and RD-13-05-2006 in terms of the requirements for magnetizing devices and magnetic particle flaw detectors. Identification of the load. It performs automatic identification of the types of connected load: cables, solenoids and electromagnet. Control of the connected load current It allows you to control the current of the connected AC/DC electromagnets and solenoids.
Produced in: Moscow