Mercury analyzer "RA-915M" with the prefix "URP"
Mercury analyzer "RA-915M" with the prefix "URP"
1 supp.
Technical specifications: Continuous operation time 8 hours The dimensions of the analyzer are 470x220x110 mm The dimensions of the console are 340x240x120 mm Analyzer weight 7.5 kg The weight of the console is 5.5 kg Power supply 220 V Supply voltage of RA-915M: (220 ±22) V, 50 Hz URP supply voltage: (220±22) V, 50 Hz Power consumption of RA-915M: 35 VA URP power consumption: 220 VA Current frequency 50 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury Monitor type RA-915AM for Natural Gas Analysis
Mercury Monitor type RA-915AM for Natural Gas Analysis
1 supp.
Technical specifications: Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 Volume flow rate of the analyzed gas at the monitor inlet, dm3/min, not less than 4 Monitor power supply from AC mains: voltage, V frequency, Hz 220 ± 22 50 ± 1 Power consumption, In × A, not more than 150 Overall dimensions (LXC), mm, no more 665x482x222 Weight, kg, not more than 25 Operating conditions: - ambient temperature, °C from 10 to 35 - relative humidity (at 25 °C), %, not more than 80 - atmospheric pressure, kPa from 84 to 106.7 - relative humidity of the analyzed gas (at 20 °C), %, not more than 99 Average time to failure, h 12000 Average service life, 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury monitor type RA-915AM for air analysis
Mercury monitor type RA-915AM for air analysis
1 supp.
Technical specifications: Ambient temperature, °C from +10 to +35 Relative humidity (at +25 °C), % no more than 98 Atmospheric pressure, kPa from 84 to 106.7 Power supply 220  22 V, 50  1 Hz Power consumption, VA no more than 150 Overall dimensions (LWC), mm Monitor Multiplexer 665x482x222 665x482x222 Weight, kg Monitor Multiplexer (2-16 channels) 25 15 - 25 Average time to failure, h 12000 Average service life, 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Microparticle analyzer "SKAT-1"
Microparticle analyzer "SKAT-1"
1 supp.
Technical specifications: The time of one measurement is not more than 60 seconds Output of results to digital display board, RS485, RS232; current loop 4-20 mA, (0-20) mA The pressure in the flow is 0.1-10 atm. The range of detectable concentrations of suspended particles is 0.02-5 SCAT-1(VC); 0.1-100 SCAT-1(n) mg/l Execution B4, P1, N1 according to GOST 12997-84 Category of climatic execution UHL4 according to GOST 15150-69 Relative humidity at +25 ° C is not more than 80% The error of photometry per channel is not more than 1% The size of the analyzed microparticles is 0.5-50 microns Display modes NORM, ALARM, LIMIT The temperature of the analyzed flow is from +0.5 to +50 °C Ambient temperature from +0.5 to +50 °C Atmospheric pressure 84-106.7 kPa The warranty period of operation is 1 year Average service life of at least 5 years Dimensions 300x400x150 mm Weight not more than 20 kg Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption 100 W
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with the prefix "RP-91NG"
Mercury analyzer "RA-915M" with the prefix "RP-91NG"
1 supp.
Technical characteristics: The set-top box is powered by AC (220 ± 22) V, 50 Hz Power consumption, VA, no more than 35 Continuous operation time, h 8 Overall dimensions: (LxWxH), mm, no more than 320x290x160 The weight of the console, kg, not more than 6.5 Air consumption, dm3/min 2 ... 5
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
2 supp.
from 218.11 ₽
Technical specifications: Ionization method Glow discharge plasma Discharge gas Air Time-of-flight Mass Analyzer with mesh-free ion mirror Resolution 4000 The number of simultaneously defined components is not limited Mass range 1-1000 m/z Detection limits 10-100 ppt Analysis time 1-3 min Vacuum system 1 Booster pump and 2 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with the prefix "RP-92"
Mercury analyzer "RA-915M" with the prefix "RP-92"
1 supp.
Technical specifications: Continuous operation time 8 hours Analyzer dimensions (LxWxH), mm, no more than 470x110x220 mm Overall dimensions of the pumping unit: (LxWxH), mm, no more than 360x110x125 mm Analyzer weight 7 kg The weight of the console is 7 kg Power supply 100 - 240 V Powered by an autonomous RA source-915+ - 6/14 In Powered by an autonomous source RP-91 - 12 V Power consumption 20 W Current frequency 50/60 Hz The mass of the pumping unit is 3 kg Average service life, years, at least 5 Volume of the injected sample, cm3 0.5 - 10.0 Air flow, dm3/min 0.8 - 4.2
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
1 supp.
Technical specifications: The upper limit of the measurement range is 5 mg/kg Analysis time 1-5 min Permissible sample weights are 10-500 mg The weight of the console is 17 kg Air pumping speed 1-3 l/min Dimensions and weight of the analyzer 470x210x110 mm; 7.5 kg Power supply of the PIRO-915+ 220 V, 700 W Analyzer power supply 220 V, 15 W Dimensions of the power supply and pumping unit no more than 400x280x135 mm The dimensions of the thermal camera unit and the remote optical unit are no more than 430x340x135 mm The upper limit of the measurement range for sample weighting is 20 mg 200 mg/kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Sample preparation system – microwave mineralizer "MINOTAUR®-2"
Sample preparation system – microwave mineralizer "MINOTAUR®-2"
1 supp.
Technical specifications: Frequency of the generated magnetron radiation, MHz 2450 ±50 Number of simultaneously decomposed samples 1 The maximum volume of the processed sample, cm3 50 Maximum working pressure in the container, atm 9 Power consumption, V*A 600 The average absorbed power (W) in the reactor when heating 30 cm3 of distilled water at 100% output power level of the magnetron in the range of supply voltage from 187 to 242 V 150... 250 Average time to failure, h, not less than 2500 Average service life, years, at least 5 Overall dimensions, mm, no more than 500x450x150 Weight, kg, no more than 22
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Alonge type "Spider" with vacuum valves KV-19 14/23-19/26 Primelab
Alonge type "Spider" with vacuum valves KV-19 14/23-19/26 Primelab
1 supp.
The "Spider" type with vacuum valves KV-19 14/23-19/26 Primelab has a non-standard appearance. Serves as a connecting element in laboratory installations, apparatus and devices. It has a reliable design that guarantees excellent tightness and prevention of gas leakage. The product is made in accordance with GOST from borosilicate glass, which does not enter into chemical reactions with contacted substances and is not afraid of temperature changes. The Primelab company accepts orders for the production of equipment and glassware according to the customer’s individual parameters.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Biochemical analyzer (photometer) "BIALAB-100"
Biochemical analyzer (photometer) "BIALAB-100"
1 supp.
Technical specifications: Methods of analysis optical density, endpoint, kinetics, fixed time, nonlinear, two-wave, turbidimetry Light source halogen lamp (12 V, 20 W) with a slow start system to increase the service life Built-in interference light filters 340, 405, 505, 546, 578, 630nm; spectral half-width 12 nm The optical density measurement range is 0-2.5 E.O.P. The measurement error of optical transmission is not more than 1 % Memory of 100 measurement programs Temperature control of the measuring cell built-in thermostat with Peltier element: 25, 30, 37 ° C; accuracy ± 0.2 ° C Sample incubation thermostat external, for 16 vials The volume of the flow cell is 32 µl Consumption of the working reagent from 250 µl Built-in matrix printer, printing on plain paper with a tape width of 56 mm Liquid crystal display: 4 lines of 20 characters each Productivity of up to 100 analyses/hour by the endpoint method Dimensions and weight no more than 355x355x185 mm; 8.5 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Chromatographic columns for HPLC
Chromatographic columns for HPLC
1 supp.
Variants of execution: - silica gel with grafted octadecyl groups (C18, RP, ODS) - for the variant of reversed-phase HPLC (OF HPLC); - unmodified silica gel (SIL) – for normal-phase HPLC (NF HPLC).
Lumeks
Saint Petersburg
Produced in: Saint Petersburg