      Generator of test pulses G9-1A
      Generator of test pulses G9-1A
      The generator is capable of operating both autonomously and as part of automated measuring systems with interfaces such as RS-232 and ITHERNET. Technical specifications The range of setting the pulse duration at the outputs: - τ1 from 100 ns to 10 s - t2 from 101 ns to 10.1 s - t3 from 10 ns to 3600 s The range of setting the time interval between the pulse fronts at outputs t1 and t2 (∆tx) is from 0 to 3600 s The main error in setting the pulse duration at outputs t1 and t2 ± (δ0 • t1,2 + 1•10-8 c) The basic error of setting the pulse duration at the output is τ3 ± (δ0 •τ3 + 2 •10-9 s) The main error in setting the duration of the time interval (∆tx): ∆tx from 0 to 1000 s ± (δ0 •∆tx + 2•10-10 s) ∆tx from 1000 to 3600 s ± (δ0 •∆tx + 2•10-9 s) Pulse amplitude at outputs τ1 , τ2 and τ3 at a load of 50 ohms, not less than 1.2 V The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator (δ0 ), no more than ± 2x10-7 in 24 months The pulse repetition frequency setting range at outputs τ4 and τ5 is from 0.1 Hz to 300 MHz The main error in setting the pulse repetition frequency at outputs τ4 and τ5 ± δ0 •F = τ4.5 Pulse amplitude setting range at outputs τ4 and τ5 from 0.05 to 1 V The main error in setting the pulse amplitude at outputs τ4 and τ5 ± 20% Fixed values of pulse durations at the output of τ6 1 and 5 microseconds The basic error of setting the pulse duration at the output is τ6 ± (0.2•τ6 + 3 •10-7 s) The nominal value of the pulse repetition frequency at the output is τ6 100 kHz The main error in setting the pulse repetition frequency at the output is τ6 ± δ0 •F = τ6 Fixed values of the pulse amplitude at the output of τ6 minus 10 V; minus 2.5 V; 2.5 V; 10 V The main error in setting the pulse amplitude at the output is τ6 ± 20% Operating temperature range from 5°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 442x160x452 Weight, not more than 10 kg
      Produced in: Moscow
      Mobile laboratory of measuring equipment PLIT-A2-4/1M
      Mobile laboratory of measuring equipment PLIT-A2-4/1M
      The complex is equipped with air conditioning, heating and ventilation systems to create and maintain a preset temperature level (20 ...25) ° C in the van body, at an outdoor temperature from minus 40 ° C to 40 ° C. PLIT-A2-4/1M is equipped with a removable diesel electric unit with a capacity of 16 kW, which ensures the functioning of all systems in autonomous mode. A set of functionally related working standards, special equipment and automation tools allows you to implement comprehensive metrological maintenance of measuring instruments at workplaces
      Produced in: Moscow
      Universal mobile complex for verification and repair of measuring instruments
      Universal mobile complex for verification and repair of measuring instruments
      The complex is equipped with air conditioning, heating and ventilation systems to create and maintain a set temperature level (20-25) ° C in the container body, at an outdoor temperature from minus 40 ° C to 40 ° C. Operating conditions Ambient air temperature from minus 40 to 40 ° C; Relative humidity up to 95 % at tº= 30 ° C; Atmospheric pressure from 84.0 to 106.7 kPa (from 630 to 800 mm Hg); General-purpose power supply: alternating three-phase current with a frequency of (50 ± 1) Hz with a RMS voltage value in each phase (380 ± 38) V. A set of functionally related working standards, special equipment and automation tools allows you to implement complex metrological maintenance of measuring instruments at automated (automated) and non-automated (RM) workplaces
      Produced in: Moscow
      Spectrum Analyzer SK4-105
      Spectrum Analyzer SK4-105
      The spectrum analyzer is capable of working both independently and as part of automated measuring systems with USB and ETHERNET interfaces. Technical specifications Frequency range from 9 kHz to 20 GHz The basic error of frequency measurement is ± (3-10'7hG + 0.2 Hz) Viewing bands 0; 10 Hz - 20 GHz Bandwidth minus 3 dB from 1 Hz to 8 MHz Self-noise level from minus 156 to 145 dB MW/Hz The basic level measurement error is ± (1.2-1.8) dB The relative level of interference caused by intermodulation distortions of the 3rd order from minus 50 to 65 dB The relative level of interference caused by combination distortions from minus 60 to 80 dB Amplitude scales linear, quadratic, logarithmic (0.1- 20) dB/div The frequency range of the tracking generator is from 1 MHz to 8 GHz Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 85 VA Overall dimensions, mm 420x213x172 Weight, not more than 8 kg
      Produced in: Moscow
      Universal voltmeter V7-79
      Universal voltmeter V7-79
      The voltmeter is capable of operating both independently and as part of automated measuring systems with RS-232 interfaces. Technical specifications Measuring ranges of electrical quantities: - constant electrical voltage from 10 MV to 1000 V - SCR of alternating electric voltage in the frequency range from 10 Hz to 10 MHz (AC) from 1 mV to 750 V - RF RF AC voltage in the frequency range from 10 kHz to 1500 MHz (RF) from 10 mV to 1000 V - DC electric current from 0.1 µA to 20 A - SCZ of alternating electric current in the frequency range from 10 Hz to 5 kHz from 10 µA to 20 A - electrical resistance from 10 mOhm to 1 GOm - frequency of the measured AC voltage from 10 Hz to 1 MHz Measurement errors of electrical quantities: - constant electrical voltage ± (0.0028 - 20)% - SCR of alternating electric voltage in the frequency range from 10 Hz to 10 MHz (AC) ± (0.09 - 15)% - RF RF AC voltage in the frequency range from 10 kHz to 1500 MHz (RF) ± (1.6 - 66)% - DC current ± (0.012 - 20)% - SCR of alternating electric current in the frequency range from 10 Hz to 5 kHz ± (0.11 - 2.35)% - electrical resistance ± (0.007 - 5.5) % - frequency of the measured alternating electric voltage ± (0.1 -10.1) % General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 20 VA Overall dimensions, mm 291x110x308 Weight, not more than 4.5 kg
      Produced in: Moscow
      PKV-IB-7,2×3,4
      PKV-IB-7,2×3,4
      Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Type of coaxial connector (according to GOST RV 51914-2002) IB Frequency range, GHz 25.96-37.50 VSWR 1.35
      Produced in: Moscow
      Universal voltmeter V7-81
      Universal voltmeter V7-81
      The voltmeter is capable of operating both independently and as part of automated measuring systems with RS-232 type interfaces. Technical specifications Ranges of measurement of electrical quantities: - constant electrical voltage from 10 MV to 1000 V - SCR of alternating electric voltage in the frequency range from 10 Hz to 10 MHz (AC) from 1 mV to 750 V - DC current from 0.1 µA to 20 A - SCR of alternating electric current in the frequency range from 10 Hz to 5 kHz from 10 µA to 20 A - electrical resistance from 10 mOhm to 1 GOm - frequency of the measured alternating electric voltage from 10 Hz to 1 MHz Measurement errors of electrical quantities: - constant electrical voltage ± (0.0028 - 20)% - SCR of alternating electric voltage in the frequency range from 10 Hz to 10 MHz (AC) ± (0.09 - 15)% - DC power ± (0.012 - 20)% - SCR of alternating electric current in the frequency range from 10 Hz to 5 kHz ± (0.11 - 2.35) % - electrical resistance ± (0.007 - 5.5)% - frequency of the measured alternating electric voltage ± (0.1 -10.1)% General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 20 VA Overall dimensions, mm 291x110x308 Weight, not more than 4.5 kg
      Produced in: Moscow
      UCHX2-78
      UCHX2-78
      Basic properties: Wide frequency range; Sufficiently large output power; High level of suppression of side harmonics of the input signal; Low phase noise value; Relatively simple technical solutions: - synchronization and frequency stabilization, - stabilization and adjustment of the output power level, - implementation of amplitude and frequency modulation modes; Do not require external bias diodes. Operating conditions: Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical characteristics Input/output frequency range, GHz 26,78-39,17 / 53,57-78,33 Losses (max.), dB 15 Input power level, dBm 15-21 Unevenness of output power (Rvh. = 20 dBm), dB ± 2.0 The level of parasitic harmonics of the input signal at the output (min.), dBn 20 Output VSWR (max.) 2.0 Connector type: • Input Coax. 2.4/1.0 mm (plug/socket) • Output Waveguide 3,759x1,88 mm (50-75GGo) Overall dimensions, mm 26x20x20 Weight, g 50
      Produced in: Moscow
      PM-8 verification module
      PM-8 verification module
      The composition of the PM-8 verification module Frequency comparator CHK7-1011; Universal frequency meter Ch3-89; AC voltage voltmeter VK3-78A; Universal voltmeter V7-81; AC voltage calibrator H5-5; High-frequency signal generator G4-227; High-frequency signal generator G4-229; High-frequency signal generator G4-230; Absorbed power wattmeter M3-108; Installation for measuring attenuation D1-24/1; Device for measuring attenuation stepwise D1-25; Computational modulation meter SK3-49; The meter-calibrator of the harmonic coefficient SK6-20; Spectrum analyzer SK4-"Belan 240"; VSWR panoramic meter R2-135; VSWR panoramic meter R2-137; A set of exemplary measures of the transmission coefficient H3-7; Oscilloscope S1-157/4; DC power supply B5-79/1; AC power source B2-7 (2 pcs.); Electronic switch of microwave signals; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical quantities: Constant electrical voltage from 3 MV to 1000 V Alternating electric voltage in the frequency range of 10 Hz ... 2000 MHz from 10 mV to 100 V Frequency of continuous electromagnetic oscillations from 0.001 Hz to 17.85 GHz The power of continuous electromagnetic oscillations in the frequency range of 20 MHz ... 17.85 GHz from 0.8 to 10 MW Attenuation of electromagnetic oscillations in the frequency range 0.1 MHz ... 17.85 GHz from 0 to120 dB VSWR in the frequency range 0.2 ... 17.85 GHz from 1.03 to 2 Harmonic coefficient in the frequency range of 10 Hz ... 8 GHz from 0.005 to 100 % The amplitude modulation coefficient in the carrier frequency range of 100 kHz ... 17.85 GHz from 0.1 to 100 % Frequency deviation in the carrier frequency range of 100 kHz ... 17.85 GHz from 5 Hz to 1 MHz Phase modulation index in the carrier frequency range 100 kHz ... 17.85 GHz from 1 to 100 radians Phase shift between two harmonic signals in the frequency range 0.1 MHz ... 17.85 GHz from 0 to 360o Ranges of reproduction of electrical quantities: Alternating electrical voltage in the frequency range of 10 Hz ... 2000 MHz from 3 MV to 3 V Harmonic (sinusoidal) signal at a load of 50 ohms in the frequency range of 0.001 Hz ... 30 MHz from 0.01 to 5 V Continuous electromagnetic oscillations in the frequency range of 9 kHz ... 17.85 GHz from minus 120 to 13 dBm 5 and 10 MHz reference frequency signal Attenuation of electromagnetic oscillations in the frequency range 0 ... 3 GHz from 0 to 86 dB Measurement errors of electrical quantities: Constant electrical voltage ± (0.0025 ... 16.7) % Alternating electric voltage in the frequency range 10 Hz ... 2000 MHz ± (0.2 ... 16) % Frequency of continuous electromagnetic oscillations ± (2·10-7 ... 4·10-3) Power of continuous electromagnetic oscillations in the frequency range 20 MHz ... 17.85 GHz ± (4 ... 6) % Attenuation of electromagnetic oscillations in the frequency range 0.1 MHz ... 17.85 GHz ± (0.01 ... 1.2) dB VSWR in the frequency range 0.2 ... 17.85 GHz ± (3 ... 5) K Harmonic coefficient in the frequency range 10 Hz ... 8 GHz ± (0.005 ... 6) % Amplitude modulation coefficient in the carrier frequency range 100 kHz ... 17.85 GHz ± (0.1 ... 9) % Frequency deviation in the carrier frequency range 100 kHz ... 17.85 GHz ± (0.2 ... 80) Hz Phase modulation index in the carrier frequency range 100 kHz ... 17.85 GHz ± (0.02 ... 5) radians Phase shift between two harmonic signals in the frequency range 0.1 MHz ... 17.85 GHz ± (0.01 ... 0.08) o Errors in the reproduction of electrical quantities: Alternating electrical voltage in the frequency range 10 Hz ... 2000 MHz ± (0.16 ... 10) % Harmonic (sinusoidal) signal at a load of 50 ohms in the frequency range 0.001 Hz ... 30 MHz ± (3 ... 5) %; Continuous electromagnetic oscillations in the frequency range of 9 kHz ... 17.85 GHz ± (0.5 ... 3) dB 5 and 10 MHz reference frequency signal ± (2·10-11 – 2,4·10-10) Attenuation of electromagnetic oscillations in the frequency range 0 ... 3 GHz ± (0.2 ... 1.4) dB General technical characteristics: The area occupied by the module is 6-12 m2 Weight, not more than 550 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, no more than 3000 VA
      Produced in: Moscow
      AC voltage source B2-9
      AC voltage source B2-9
      The source is capable of operating both independently and as part of automated measuring systems with interfaces such as RS-232 and ETHERNET. Technical specifications Output voltage setting range (SCR) from 25 to 250 V The discreteness of the output voltage setting is 0.05 V The frequency setting range of the output voltage is from 40 to 500 Hz The discreteness of the output voltage frequency setting is 0.05 Hz Output electrical power, not less than 1000 VA The basic error of setting the output voltage is ± (0.005 Uv + 0.5 V) The basic error of setting the output voltage frequency is ± 0.1 Hz Additional error in setting the output voltage caused by a change in the load current from the maximum value to zero ± 0.5 V Instability of the output voltage for any 10 minutes during 8 hours of continuous operation, no more than ± 0.5 V Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 1300 VA Overall dimensions, mm 343x160x352 Weight, not more than 6.5 kg
      Produced in: Moscow
      Verification module PM-10
      Verification module PM-10
      The composition of the PM-10 verification module: Wattmeter of passing power M2-35; Complex transmission and reflection coefficients meter "OBZOR-804/1"; Universal voltmeter V7-81 (2 pcs.); High-frequency signal generator G4-229; High-frequency signal generator G4-230; DC power supply B5-79/1 (2 pcs.); AC power source B2-7 (2 pcs.); The measure of DC electrical resistance is multi-valued MS3070-3, CT 0.005; The measure of DC electrical resistance is multi-valued MS3055, CT 0.02; Single-digit electrical resistance measures MS3080 (0.1; 1 ohm, CT 0.005); Thermoelectric voltage converter 0.5 V; Kit for measuring coaxial connectors KISK-7M; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical and radio engineering quantities: Operating frequency range from 0.03 to 17.85 GHz Passing microwave power from 0.01 to 10 MW VSWR of the microwave tract from 1.05 to 3 Constant electrical voltage from 10 MV to 1000 V Alternating electric voltage from 1 mV to 750 V Thermoelectric voltage comparison from 0.1 to 0.5 V Ranges of reproduction of electrical quantities: Constant electrical voltage from 1 to 120 V Resistance to direct electric current from 0.01 to 122222.21 ohms Measurement errors of electrical and radio engineering quantities: Passing microwave power ± (1.5 - 2.3) % VSWR of the microwave path ± (4,15 – 10) % Constant electrical voltage ± (0.003 – 20) % Alternating electric voltage ± (0.09 - 15) % Thermoelectric voltage comparison ± (0.01 – 0.1) % Errors in the reproduction of electrical quantities: Constant electrical voltage ± (100 – 200) mV Resistance to direct electric current CT 0.005; 0.02 General technical characteristics: The area occupied by the module is 4 – 8 m2 Weight, not more than 340 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, not more than 2000 VA
      Produced in: Moscow