Accessories

358 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 20
    Applying
    Loading...
  • 93
    Names
    Loading...
  • 36
    Manufacturer
    Loading...
  • 23
    Made in
    Loading...
  • 26
    Additional
    Loading...
View:
358 products
Microassembly RB1S8KN009
Microassembly RB1S8KN009
Two-channel analog switch with signal summation function Designed for use in oscilloscopes with a bandwidth up to 350 MHz. Technical specifications: The value of the voltage between the outputs of the switch at load resistance RN = (50 ± 2.5) ohms and opening voltages UU1 = (2.0 ± 0.2) V and locking UU2 = (4.2 ± 0.2) V channels supplied alternately to the corresponding inputs (start 1, start 2) of the switches must be: in the absence of an input signal from minus 0.1 to plus 0.1 V with an input signal UC = (0.3 ± 0.05) V supplied to one of the inputs of the open channel (0.45 ± 0.1) V with an input signal UC = (0.3 ± 0.05) V supplied to one of the inputs of both open channels (0.45 ± 0.1) V
MNIPI
Minsk
Produced in: Belarus, Minsk
Cruciform connectors
Cruciform connectors
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
TWO-STAGE THERMAL DESORBER TDS-4
TWO-STAGE THERMAL DESORBER TDS-4
The composition of the TDS-4 includes the thermal desorber itself (the thermostat of the sorption tube, a cryolovushka, an automatic switching valve, a touch control panel), a heated transition line that is installed in the evaporator\ Technical characteristics of TDS-4 Temperature of thermal desorption, 0C to 400 The heating rate of the sorption tube, 0C/min up to 500 Trap temperature, 0C from minus 25 to 400 Trap heating speed, 0C to 2000 The method of heating the trap is direct Tap heating temperature, 0C to 250 Transition line heating temperature, 0C to 250 Continuous operation mode Dimensions of the sorption tube, (diameter; length), mm. Material glass, stainless steel 5/114 (on request 6/115, 6,3/89 and their combinations) Tube material glass or stainless steel (SS316) Method of trap cooling without using liquid refrigerant The number of regulated gas flows is not less than 2 There is an automatic leak test function There is a function of automatic purging of the sorption tube Electric power supply from 187 to 242 V, 50 Hz Power consumption, W not more than 700
Produced in: Yoshkar-Ola, Mari El
Holder of the TMP-D
Holder of the TMP-D
It is designed for simultaneous polishing of four copper plates measuring 75×12.5×2 mm used in determining the corrosive effect of fuels in accordance with GOST ISO 2160, GOST 32329, GOST 6321, GOST 2917 and ASTM D130.
Produced in: Tomsk
Screw Flanges
Screw Flanges
Size of DN: 10,16,20,25,32,40. Centering rings (aluminum / stainless steel) with a circular O-ring.
Produced in: Kazan
 Adapter LT-300-A
Adapter LT-300-A
It is used to connect LT-300 thermometers to a personal computer via a USB interface. This is a "native" device for the ThermoChart program. The use of this adapter does not require the installation of additional drivers because it uses the HID driver built into the operating system to exchange data.
Produced in: Tomsk
CF Rotating Flanges
CF Rotating Flanges
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
Device for winding samples the State Standard R 59707
Device for winding samples the State Standard R 59707
It is used in determining the cold resistance of plastic in accordance with the State Standard R 59707.
Produced in: Tomsk
TRANSFORMER OIL INPUT DEVICE
TRANSFORMER OIL INPUT DEVICE
When determining the total gas content (air) and humidity of transformer oil, direct injection of transformer oil into the evaporator of the chromatograph is used. The sample volume is up to 25 µl, the evaporator temperature is 250-350 °C. The main problem with such an input is the protection of the chromatographic column from transformer oil. For this purpose, a special evaporator is used with the possibility of oil accumulation at the bottom of the evaporator and its subsequent discharge, and a replaceable pre-column that protects the column from oil residues that have passed the evaporator. technical specifications The volume of the evaporator is 10 ml. The number of replaceable pre—columns in the device kit is 5. The temperature of the evaporator is from 250 to 350 °C. The possibility of draining the transformer oil accumulated in the evaporator.
Produced in: Yoshkar-Ola, Mari El
Universal holder of solid samples of various thicknesses and films
Universal holder of solid samples of various thicknesses and films
It is used for recording transmission spectra of medium–sized and arbitrary-shaped solid samples - polymer films of various thicknesses, optical parts, semiconductor wafers, large crystals, etc. • Thanks to quick-release nuts, it provides convenient fastening of samples
SIMEKS
Novosibirsk
Produced in: Novosibirsk
SAC500 lenses
SAC500 lenses
Technical specifications Material: S-TIH53 (Ohara) Length, mm: 5.8±0.02 Height, mm: 1.5±0.02 Thickness, mm: 0.55±0.01 Refractive index, mm: 1.823 Pitch, mm: 0.5 Radius, mm: 1.49 Effective focal length, mm: 1.81 Back focal length, mm: 1.5 Transmission, %: >99.5 Antireflection coating, nm at one of the wavelengths from the range: 400-1500 Numerical aperture: 0.09 Surface quality at λ = 633 nm% λ/4 Residual deviation in the full angle FW1/e2 (for non-linear deviation of the laser diode), mrad: 90.0
INZHEKT
Saratov
Produced in: Saratov
FAC300 lenses
FAC300 lenses
Technical specifications Material: S-TIH53 (Ohara) Length, mm: 4 Height, mm: 0.5±0.02 Thickness, mm: 0.4±0.01 Refractive index, mm: 1.823 Effective focal length, mm: 0.3 Rear focal length, mm: 0.08 Transmission, %: >99.5 Power within the angle ± 2.2 mrad, %: >92 Antireflection coating, nm at one of the wavelengths from the range: 400-1500 Numerical aperture: 0.7 Surface quality λ = 633, nm: λ/4
INZHEKT
Saratov
Produced in: Saratov