Muffle furnace LF-15/13-G2
Muffle furnace LF-15/13-G2
Design features: Programmable microprocessor temperature controller; Three programs of ten steps with the ability to set the temperature, heating speed and holding time for each step; Manual heating mode with timer with sound notification and auto-off; Durable ceramic muffle; Semi-open heaters on four sides of the chamber; Backlit graphic display; Conveniently located control panel; Automatic shutdown of heating when opening the door; Sound and light alarm when the current temperature exceeds the limits of the permissible interval; The door opens up and faces the user with the cold side; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than mm 215x190x330 Overall dimensions, WxHxD, not more than mm 525x655x680 Rated supply voltage, 220 V Rated power, W 6100
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Sulfur Analyzer SPECTROSCAN SW-D3
Sulfur Analyzer SPECTROSCAN SW-D3
The analyzer is designed to determine the mass fraction of sulfur in automotive fuel in accordance with GOST R 52660-2006 / GOST ISO 20884-2016, ASTM D6334, as well as in oil and petroleum products according to GOST R 53203-2008 / GOST 33194-2014, ASTM D2622, GB/T 11140-2008. Depending on the customer's needs, the analyzer is configured to work in accordance with a particular standard. Implements an arbitration method for measuring the mass fraction of sulfur in automobile fuel of the third, fourth and fifth classes. The device is designed specifically for high-quality and fast X-ray fluorescence analysis of fuel in accordance with the technical regulations "On requirements for automotive and aviation gasoline, diesel and marine fuel, jet fuel and heating oil", which establishes an arbitration X-ray fluorescence wave dispersion method for determining the mass fraction of sulfur in automotive fuels of the third, fourth and fifth classes. The wave dispersion sulfur analyzer SPECTROSCAN SW-D3 is designed taking into account all the requirements for the process of X-ray fluorescence elemental analysis of low sulfur contents in petroleum products. The operator's actions when performing measurements are minimized: - the number/name of the sample is entered from the built-in keyboard; - the sample is poured into two cuvettes; - the obtained samples are placed in the analyzer and measurements are started. The analyzer performs all subsequent actions automatically without operator involvement: - calculates and displays the sulfur content in the sample; - calculates convergence - the difference in determining the mass fraction of sulfur in the first and second samples; - prints measurement results on the built-in printer.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Electric cabinet vacuum drying SHSV-3,5.3,5.6/2.5-S
Electric cabinet vacuum drying SHSV-3,5.3,5.6/2.5-S
This electric vacuum drying cabinet is designed for drying and heating various materials in air and in vacuum at temperatures up to 250 ° C. A viewing window Ø 160 mm is installed in the door. The illumination of the working chamber is provided from the outside. An additional, independent security system is installed in the cabinet, interrupting the supply of the cabinet when operating temperatures exceed.
Produced in: Tula
Circulation thermostat LT-211b
Circulation thermostat LT-211b
The LOIP LT-211b modification device consists of an immersion thermostat-circulator LOIP LT-200 and a working bath with a lean-to hinged lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 10.5 pressure, 0.27 bar Bath volume, l 11 The working fluid is water, water-glycerin mixture, silicone oil. The open part of the bath / depth, mm 160x240/200 Overall dimensions, mm 268x335x420 Weight, kg 10
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Chamber furnace with sliding hearth SNOT 15.15.12,5/12,5
Chamber furnace with sliding hearth SNOT 15.15.12,5/12,5
from 680 000 ₽
Designation: SNOT 15.15.12,5/12,5 Temperature: 1250 Door opening: Electromechanical Hearth drive: electromechanical Camera size (WSHG): 1250x1500x1500 Regulation zones: 1
Produced in: Tula
Metal tripod Sh-10/18, pack.30 pcs, MiniMedProm
Metal tripod Sh-10/18, pack.30 pcs, MiniMedProm
from 195 ₽
The tripod is made of aluminum, which allows them to be sterilized at any temperature; this material provides lightness and durability. It can be used in water baths. The tripod has an individual packaging. Designed for storing test tubes.
MiniMed
Suponevo
Produced in: Bryansk region
Electrolysis plant
Electrolysis plant
A hydrogen production plant is a special equipment designed to produce hydrogen gas and oxygen by electrochemical decomposition of water into its main elements (in short, electrolysis of water). Today there are three ways to implement the electrolysis technology of hydrogen production, differing in the type of electrolyte used and the conditions of electrolysis. The electrolysis plant has a modular type of construction. A standard stationary installation consists of one or more electrolysis units and one process unit. The number of electrolysis units depends on the performance of the installation and the need to reserve electrolyzers (for objects of increased responsibility).
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Vacuum drying cabinet SNVS-40/5
Vacuum drying cabinet SNVS-40/5
They are designed for carrying out various technological processes at temperatures from 40 to 500 oC, in vacuum up to 1x10−3 mmHg, or in an inert gas of high purity. They are used for drying, light annealing, aging, low and medium tempering in an oxidizing environment, degassing of ferrous and non-ferrous metals (including copper and copper alloys), or any other materials processed under similar conditions. The program setting of heat treatment modes including vacuuming, high purity inert gas intake with repeated vacuuming allows heating in an oxidizing environment with high purity of the surfaces of the processed parts, without scale formation and oxidation.
Produced in: Tula
Platform scales ERW-101
Platform scales ERW-101
from 144 990 ₽
Technical characteristics: NIP, KG101 Discreteness, g1,0 External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g50 Accuracy class according to GOST OIML R 76-1-2011II high Limits of error allowed during initial verification, goth 50g to 50kg incl. ±5.0; sv.50kg to 52kg incl. ±10.0 Dust and moisture protection (IP)54/65 (on request) Setting time, s, no more than 3 Weight adjustment 40kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
CD-1 Paint detector of defects 220V
CD-1 Paint detector of defects 220V
from 60 000 ₽
The principle of operation: The controlled extended product (pipe, rolled or wire) is passed through the working area of the flaw detector. When a defective area is detected, the flaw detector included in the automated system sends a signal to trigger the paint meter actuator, as a result of which the paint from the marker's aerosol can is applied to the surface of the controlled product through a window in the device housing. Features and benefits: - Any standard aerosol cans with a diameter of 68 mm can be used in the flaw detector; - Easy replacement of the cylinder; - The device does not require connection to the pneumatic line; - High performance; - The design of the CD-1 defect meter allows connection to any standard AC and DC electrical networks with rated voltages from 12 to 380 V. Scope of application: The CD-1 automatic paint sprayer is an auxiliary equipment and is used in conjunction with flaw detectors as part of in–line automated lines for marking defects in quality control of extended products made of various materials, ferrous and non-ferrous metals and alloys - welded, hot-rolled and cold-drawn pipes, rolled products, wire and products made of them. The flaw detector can be used both in the production process and during input control on the consumer side at machine-building, transport, chemical and oil and gas enterprises. *Custom-made versions for rated voltages can be of: 12, 24, 48, 110, 127, 220, 380V.
Produced in: Moscow