Equipment

2278 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 392
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2278 products
Power supply B5-78
Power supply B5-78
Technical specifications: B5-78 (15 V, 3 A); B5-78/1 (30 V, 2 A); B5-78/2 (50 V, 1 A); B5-78/4 (20 V, 1.5 A); B5-78/6 (30 V, 4 A); B5-78/7 (50 B, 2.5 A) Voltage measurement error: ±0.3 V Current measurement error: ±(0.04–0.06) A Voltage instability when the load current changes 0.03% Instability of the current when the voltage changes at a load of 0.2% Voltage ripple 0.5–1 mV Current ripple 0.1% Power consumption 90 - 320 VA Two 3-digit indicators (voltage, current) Adjustments are rough, smooth Dimensions 115x185x360 mm Weight: 3.7 kg (B5-78, B5-78/1, B5-78/2) 3 kg (B5-78/4) 5.5 kg (B5-78/6, B5-78/7) Power supply ~220 V A
MNIPI
Minsk
Produced in: Belarus, Minsk
Cable Finder Success KBI-309N
Cable Finder Success KBI-309N
from 106 260 ₽
Description of the cable finder Success KBI-309N • – Traceroute receiver in the form of a monoblock with a large LCD display. • – The image of the route on the device screen. • – Automatic calculation and display of the depth of the communication up to 10 m, as well as the current in the line. Purpose of the cable finder Success KBI-309N • – Search for live electrical cables. • – Search and tracing of underground utilities (gas pipelines, pipelines, power and telephone cables). • – Determination of the occurrence of underground utilities at a depth of up to 10 m. Features of the AP-019.1 receiver • – Modern digital traceriscover receiver-monoblock AP-019.1. • – The image of the route on the device screen. • – Automatic calculation and display of the depth of communication and current in the line. • – Several options for displaying information on the receiver indicator: "Route", "Graph", "Graph+", "Minimum maximum", modes "Relative distance to communication" and "2-frequencies" allow the operator to use the device's capabilities as efficiently as possible. • – Additional functions when connecting external sensors. • – Wide range of operating frequencies (50(60) / 100(120) / 512 / 1024 / 8192 / 32768 Hz, wide band 40...8000 Hz, radio 8...40 kHz). • – Menu in two languages (Russian and English).
Produced in: Kolomna, Moscow region
Device for automatic isolation of nucleic acids COLIBRI
Device for automatic isolation of nucleic acids COLIBRI
from 2 840 000 ₽
1 supp.
The open system allows you to work with reagents and laboratory plastics from various manufacturers Russian-language software Modifications: - COLIBRI 24 - the ability to select from 1 to 24 samples - COLIBRI 48 - the ability to select from 1 to 48 samples - COLIBRI 96 - the ability to select from 1 to 96 samples Range of working volumes: - COLIBRI 24 - 200 – 5000 mkl - COLIBRI 48 - 30 – 1000 mkl - COLIBRI 96 - 20 – 1000 mkl A unique format of consumable plastic - 8-hole strips and combs Two built-in thermostats The accuracy of temperature maintenance is ± 1 °C Heating/cooling - up to 100 °C / up to 35 °C Universal Thermostat Tube Unit Built-in computer Ready-made allocation protocols The time of one extraction cycle is from 11 minutes Built-in bactericidal UV lamp for interior treatment
SYNTOL
Москва
Produced in: Moscow
Quattroplex Lab multiplex analyzer, 1 х 96-well plate, with peripheral devices
Quattroplex Lab multiplex analyzer, 1 х 96-well plate, with peripheral devices
1 supp.
QuattroPlex is the first Russian open multiplex platform for quantitative and qualitative analysis of biomarkers using immunofluorescence analysis on fluorescent beads. The detection technology copies xMap technology, which allows the analysis of several dozen analytes in a minimum volume. The device allows you to analyze a wide range of markers and is designed to work with 96-well plates.
Advantages of QuattroPlex Lab:
  • Multiplexity - diagnostics of up to 50 markers in one sample in one analysis;
  • analysis of a wide range of markers (rheumatology, autoimmune diseases, HLA, cytokines, infections);
  • open system - use of any test systems based on magnetic beads;
  • high sensitivity - the ability to conduct qualitative and quantitative analysis;
  • design that requires minimal space on the desktop;
  • possibility of using a 96-well plate for protocol scaling.

Technical characteristics of QuattroPlex Lab:
  • Detected bead size, microns - from 0.5 to 100;
  • 3 fluorescence detection channels;
  • fluorescence excitation wavelengths, nm - from 380 to 850;
  • fluorescence detection wavelengths, nm - from 450 to 950;
  • detector - CMOS matrix;
  • sample volume, µl - from 100;
  • number of samples studied - 96 (96-well plate);
  • the ability to load several 96-well plates in one experiment;
  • time to analyze one sample, sec - 40;
  • Software for managing and analyzing results - QuattroPlex software for processing and analyzing results, compatible with Win/Linux;
  • interfaces for connecting to a laptop/PC - Internet/Wi-Fi;
  • dimensions W×D×H, cm - 20×30×60.

Delivery set:
  • QuattroPlex multiplex biomarker analysis system;
  • starter kit of consumables;
  • computer, keyboard, mouse and monitor.
Aivok
Zelenograd
Produced in: Zelenograd
Furnace control cabinet SHUP-160-1
Furnace control cabinet SHUP-160-1
Designation SHUP-160-1 Switching power, kW 160 Automatic switch, A 320 Supply network voltage, V/Hz 380
Produced in: Tula
Vacuum drying cabinet SNVS-215/5
Vacuum drying cabinet SNVS-215/5
They are designed for carrying out various technological processes at temperatures from 40 to 500 oC, in vacuum up to 1x10−3 mmHg, or in an inert gas of high purity. They are used for drying, light annealing, aging, low and medium tempering in an oxidizing environment, degassing of ferrous and non-ferrous metals (including copper and copper alloys), or any other materials processed under similar conditions. The program setting of heat treatment modes including vacuuming, high purity inert gas intake with repeated vacuuming allows heating in an oxidizing environment with high purity of the surfaces of the processed parts, without scale formation and oxidation
Produced in: Tula
Muffle furnace MIMP-21M
Muffle furnace MIMP-21M
The furnace can be used as a universal laboratory muffle furnace in metallurgical, jewelry and ceramic production, in orthopedic dentistry, chemical and food laboratories. Technical specifications The furnace operates at ambient temperatures from 10 to 35 ° C and relative humidity up to 80% at 25 ° C. The designation of the furnace when ordering: muffle furnace MIMP-21M, where 21 indicates the volume of the working chamber of the furnace in liters. Power consumption - 6000 W Dimensions of the working chamber W×D×B – 305×300×230 mm Dimensions W×D×B – 460×580×600 mm Weight – 80 kg
MIUS
Tula
Produced in: Tula
Fluorimeter for measuring the concentration of DNA and proteins QUBIX
Fluorimeter for measuring the concentration of DNA and proteins QUBIX
from 450 000 ₽
The QUBIX fluorimeter is a device for determining the concentration of biological molecules. It is designed to detect fluorescence excited in a dye that is part of the reagents for the reaction. - Measurement of fluorescence simultaneously in 8 samples - Convenient Russian-language software - The ability to measure fluorescence in a volume of 40 µl, which is important when working with samples with a small amount of DNA
SYNTOL
Москва
Produced in: Moscow, Zelenograd
Laboratory shaft furnaces SSHOL SSHOL 15/11
Laboratory shaft furnaces SSHOL SSHOL 15/11
The furnaces can be used as universal laboratory furnaces in metallurgical, jewelry and ceramic production, in orthopedic dentistry, chemical and food laboratories. Technical specifications Universal laboratory shaft furnaces with software control SSHOL are used for firing products, melting and heat treatment of metals at temperatures up to 1150 ° C. Max. operating temperature- 1150 ⁰C Dimensions of the working chamber - Ø200x500 mm
MIUS
Tula
Produced in: Tula
Correlational leakage detector Iskor-219
Correlational leakage detector Iskor-219
from 547 170 ₽
Designed for: – determining the location of liquid leakages from pipelines by the correlation method; – tracing underground utilities with the display of the communication axis and digital measurement of the depth of occurrence; – clarification of leakage sites by acoustic leak detector; – search for the place of damage to the power cable by induction and acoustic methods; • – creation of an information database of the condition of pipelines and the results of pipeline diagnostics.
Produced in: Kolomna, Moscow region
POZIS STANDARD STAMPS Tablet press
POZIS STANDARD STAMPS Tablet press
Productivity, thousand tab./hour 140 Number of stations 31 Max. pressing force, tn 10 Number of threads 1 Diameter of tablets, mm 6-25,4 Height of tablets, mm 10-16 Matrix filling depth, mm 26 Rotor material steel 40x13 Filling hopper capacity, l 50 Changing the rotation speed of the rotor with a variator The change in the rotation speed of the feeder: forced Supply voltage 380V, 50Hz Power consumption, kW/hour 4.18 Weight, kg 2200 Dimensions, mm 900x900x1800
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan