Equipment

2222 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 387
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 99
    Additional
    Loading...
View:
2222 products
INSULATION PARAMETER METER PARMA TENSOR-2
INSULATION PARAMETER METER PARMA TENSOR-2
PARMA TENSOR-2 (AC bridge) is designed for automatic measurements of: · capacitance and tangent of the dielectric loss angle of high-voltage insulation of capacitors, inputs, transformers using an external high-voltage capacitor, both in laboratory and in the "field" conditions · effective values of the first harmonic of the current and voltage of the industrial frequency · the angle of phase shift between the signals supplied to the inputs of the device · network frequencies * Measurements can be carried out according to the "straight" and "inverse" (inverted) scheme. * Allocates the vector of the influence current, which makes it possible to dispense with the phase regulator of the test voltage source or devices for compensating the influence current.
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Rubidium frequency and time standards H1-1011/1
Rubidium frequency and time standards H1-1011/1
The modular construction principle makes it easy to adapt the devices to the specific requirements of the consumer. The standards are available in four versions – H1-1011, H1-1011/1, H1-1011/2 and H1-1011/3, which differ in metrological characteristics and a set of installed devices (modules). The built-in diagnostic system allows you to quickly determine the operability and condition of the main devices of the standards. On the front panel of the devices H1-1011 and H1-1011/2 there is an LCD display and a control panel, with which you can quickly receive information about the current parameters of the devices included in the devices and adjust the frequency of the output signals. The H1-1011 and H1-1011/2 standards can receive chronometric information from GLONASS and GPS satellite radio navigation systems and use it to synchronize the local time scale and automatically adjust the actual frequency value of the built-in highly stable rubidium frequency standard. The H1-1011 and H1-1011/2 standards include: rubidium frequency standard H1-1014; MPR-01 satellite radio navigation systems receiver module; amplifier module for highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request). The scope of delivery (at the request of the customer) includes an antenna for the SRNS receiver as part of: antenna unit; mounting device; antenna cable (maximum length 60 m). The H1-1011/1 and H1-1011/3 standards include: the rubidium frequency standard H1-1013; two modules of amplifiers of highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request).
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Muffle furnace LF-15/11-G1
Muffle furnace LF-15/11-G1
Design features: Durable ceramic muffle; Closed heaters on four sides of the chamber; Microprocessor temperature controller; Conveniently located control panel and bright LED display; Ease of management and control; LED indicators of heater operation and protection operation; Automatic shutdown of heating when opening the door; The door opens up and faces the user with the cold side; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1100 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than mm 215x190x330 Overall dimensions, WxHxD, not more than mm 525x655x680 Rated supply voltage, 220 V Rated power, W 6000
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Muffle furnace MIMP-3P (desktop version)
Muffle furnace MIMP-3P (desktop version)
The furnace can be used as a universal laboratory muffle furnace in metallurgical, jewelry and ceramic production, in orthopedic dentistry, chemical and food laboratories. Technical specifications The furnace operates at ambient temperatures from 10 to 35 ° C and relative humidity up to 80% at 25 ° C. The designation of the furnace when ordering: muffle furnace MIMP-75P, where 75 indicates the volume of the furnace working chamber in liters. Power consumption – 2500 W Dimensions of the working chamber WxDxH- 155x200×105 mm Dimensions WxDxH- 420x450x480 mm Weight – 30* kg (* - with control unit)
MIUS
Tula
Produced in: Tula
Steam generator of analytical samples of metal samples "Aspect"
Steam generator of analytical samples of metal samples "Aspect"
During operation, the steam generator of metal samples "Aspect" provides control of all devices of the atomic emission spectral analysis complex - the MAES analyzer, the Ball Lightning generator, the inclusion of external devices; A spark unipolar discharge is excited between a tungsten counterelectrode and the surface of the test samples - ingots of precious metals or other metal samples; The intensity of erosion of the sample surface is regulated by changing the repetition frequency and power of spark pulses generated by a computer-controlled semiconductor spark generator; The stability and quality of the frisking is monitored using a built-in spectrometer via optical fiber; An adjustable flow of high-purity argon passes through the spark discharge zone in a sealed discharge chamber, picks up sample particles obtained by spark erosion of the surface and transfers them in the form of an aerosol to the area of the mixer/sprayer of the inductively coupled plasma torch of the optical emission spectrometer.; The flow of high-purity argon is supplied, controlled and regulated by a microprocessor-controlled mass flow controller in the range from 0.5 to 3 l/min. Feed stability 0.01 l/min.
Produced in: Novosibirsk
Octanometer OCTANE-IM
Octanometer OCTANE-IM
Digital indication of measured values • Fuel volume for measuring 50 cm3 The minimum immersion depth of the sensor is 90 mm The time of setting the operating mode is 3 seconds Overall dimensions 470x60x35 mm Weight 0.7 kg
Produced in: Tomsk
Modular liquid cooling unit VCHV-300
Modular liquid cooling unit VCHV-300
Cooling capacity at water temperature = +20C, output.water=+15C, Current.cp.=+30C, 300 kW
Produced in: Tula
Collection for storage of purified water S-240
Collection for storage of purified water S-240
from 97 000 ₽
Designed for collecting, storing and distributing purified water obtained by various purification methods, with a capacity of 240 liters and 100% stainless steel, which allowed for a long service life. Dimensions in terms of 690x660 mm Weight 24 kg
Livam
Belgorod
Produced in: Belgorod
Optical Transceiver 1x9 OC3/STM1/Fast Ethernet (155Mbps)
Optical Transceiver 1x9 OC3/STM1/Fast Ethernet (155Mbps)
Optical transceivers are available in 9-pin plastic cases with separate optical input/output for SC (FC) connectors
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Liquid low-temperature thermostat CRYO-MT-17
Liquid low-temperature thermostat CRYO-MT-17
The operating temperature range is -30...+105 °C. Bath volume 22 l Overall dimensions 400x675x830 mm The open part of the bath is 130x162 mm Bath depth 500 mm Weight 57 kg Power consumption 3.5 kW
Produced in: Tomsk
Laboratory shaft furnace SSHOL-3/11-KP
Laboratory shaft furnace SSHOL-3/11-KP
Designation SSHOL-3/11-KP Temperature, oC 1100 Supply voltage, 220 V Power, kW 5 The amount of working space, l 2.2
Produced in: Tula
Leakage detector with the function of diagnosing shut-off valves Success AT-407ND
Leakage detector with the function of diagnosing shut-off valves Success AT-407ND
from 122 820 ₽
The leakage detector with the function of diagnosing shut-off valves "Success AT-407ND" is designed to detect places of depressurization of underground pipelines of heat, water, gas, oil supply systems at a depth of up to 3 m in channel and without channel laying. The search for damage sites is carried out by the acoustic method. The kit includes a set of "ADM-227", consisting of a small-sized acoustic sensor with a magnetic base and an extension pin. The presence of the ADM-227 kit in the leak detector makes it possible to carry out work on leak detection and monitoring the condition of shut-off valves, both on metal and plastic pipes of small diameter. The leak detector allows you to detect violations of the tightness of the shut-off valves. If the sealing of the shut-off element is violated, the product (liquid or gas) leaks. Characteristic acoustic leakage noises are detected by the high-quality microphone of the sensor kit "ADM-227".
Produced in: Kolomna, Moscow region