Equipment

2245 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 389
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2245 products
Industrial Drying Cabinet SNOL (SHS) 1700/3-I2 V
Industrial Drying Cabinet SNOL (SHS) 1700/3-I2 V
from 1 743 987 ₽
Industrial drying cabinet SNOL (SHS) 1700/3-I2 V is designed for drying, tempering, aging, thermal testing and other types of heat treatment of various materials in an air environment at temperatures up to 350 (optionally up to 500) ° C with forced air convection in stationary conditions.
LB42-Sh Laboratory bath
LB42-Sh Laboratory bath
It is intended for thermostating samples in glasses, flasks and other laboratory utensils in cases where high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. Four workstations with a diameter of 110 mm with five steel O-rings, tripods and feet with a clip. Stamped steel tub with a volume of 13 liters and a depth of 110 mm. Bath volume 13 l Overall dimensions 540x640x660 mm The open part of the bath is 325x290 mm Bath depth 110 mm Weight 10.5 kg Power consumption 2.5 kW
Produced in: Tomsk
INSTALLATION OF DOSIMETRIC BETA RADIATION UDB‑AT200
INSTALLATION OF DOSIMETRIC BETA RADIATION UDB‑AT200
Transmission of units of absorbed dose, directed, individual dose equivalents and their beta radiation power as part of the working standard of absorbed dose (PD) and absorbed dose power (MPD) of beta radiation in a tissue equivalent substance. ▪ Use of closed radionuclide beta radiation sources 90Sr+90Y (BIS-50, 22 GBk), 85Kr (KAC.D3, 15 GBk) and 147Pm (BIP-50, 10 GBk) ▪ Formation of a reference field from sources by a mobile emitter unit using smoothing filters ▪ Source holders with shutter and protective screens ▪ Calibrated length rods and laser device for centering and digitizing ▪ A video surveillance system of readings ▪ The possibility of using an automated extrapolation chamber as part of the installation to reproduce the absorbed dose (absorbed dose rate) of beta radiation in the tissue ▪ Measurement of ionization currents from 1 fA when using an extrapolation chamber and a precision electrometer ▪ Software for installation operation, calibration and calculations ▪ An alarm and blocking system, control of photon radiation levels in the measurement room and operator room
Produced in: Belarus, Minsk
Muffle furnace LF-7/13-G1
Muffle furnace LF-7/13-G1
Design features: Durable ceramic muffle; Semi-open heaters on four sides of the chamber Microprocessor temperature controller; Conveniently located control panel and bright LED display; Automatic shutdown of heating when opening the door; Ease of management and control; LED indicators of heater operation and protection operation; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x110x285 mm Overall dimensions, WxHxD, not more than 505x565x655 mm Rated supply voltage, 220 V Rated power, W 3300
LOIP
Saint Petersburg
Produced in: Saint Petersburg
TS-V-1 Dry Cooler
TS-V-1 Dry Cooler
from 67 173 ₽
Dry coolers (autonomous cooling system) are designed to circulate and cool the liquid, which ensures the permissible temperature of the heat-generating object. The product is adapted to work with vacuum drying cabinets of the "SNVS" and "SHSV" type manufactured by TULA-TERM LLC, having a liquid-cooled flange, as well as any equipment using liquid cooling and suitable in characteristics.
Produced in: Tula
Circulation thermostat LT-216a
Circulation thermostat LT-216a
The LOIP LT-216a modification device consists of an immersion thermostat-circulator LOIP LT-200 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 10.5 pressure, 0.27 bar Bath volume, l 16 The working fluid is water, water-glycerin mixture, silicone oil. The open part of the bath / depth, mm 190x296/200 Overall dimensions, mm 355x335x42 0 Weight, kg 11.5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
AO-3 cooler
AO-3 cooler
1 supp.
According to the requirements of the standards, the cooler is included in the list of equipment for determining humidity with pre-drying. Usually, grain samples after preliminary drying are cooled in the laboratory room to ambient temperature. However, with such cooling, the ambient temperature reaches only the surface layers of the samples, which affects the results of the analyses. The principle of operation of the cooler is based on blowing sample canopies in mesh buckets placed on a stand by a fan rotating at high speed. Advantages: Rapid cooling of samples. Stable moisture distribution. Allows you to significantly improve the accuracy of the results of determining humidity.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
hydrogen meter MARK® 509 A
hydrogen meter MARK® 509 A
Continuous measurements of dissolved hydrogen concentration and temperature of aqueous media with excess hydrostatic pressure up to 20 MPa Unique, patent-protected sensor design | Stability of operation with changes in hydrostatic pressure | Permissible short-term (up to 5 minutes) pressure overload (water hammer) – up to 40 MPa | Easy and fast membrane replacement | The sensor is not afraid of "drying" | The calibration interval is 6 months | Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
A set of equipment for determining the total sludge content in residual liquid fuels OPF-LAB-02
A set of equipment for determining the total sludge content in residual liquid fuels OPF-LAB-02
Features: Sediment measurement up to 0.5% by weight; Two brass test cells; Coils for heating/cooling each cell; Buchner flask 500 ml in a protective casing; Steam generator with a capacity of 1.7 liters; Vacuum gauge; Thermocouple for determining the temperature of steam at the entrance to the cell circuit; 6-bed water bath for sample preparation included; Tubes for steam, water, vacuum tubes included. The composition of the kit: Filter unit OPF-LAB-02 1 pc. LOIP SG-101 steam generator 1 pc. Vacuum source 1 pc. Liquid thermostat LOIP LT-840 1 pc.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
VT5-2 Liquid thermostat
VT5-2 Liquid thermostat
It is designed to maintain a set temperature of a liquid coolant circulating both in an internal bath and in external consumers of closed or open type. Pump for closed or open type thermostating systems. All-metal stamped tub with a volume of 5 liters and a depth of 200 mm. The stability and uniformity of the temperature in the inner bath is not worse than ± 0.1 ° C. The operating temperature range is +20...+200 °C. The volume of the bath is 5 liters Overall dimensions 170x350x480 mm The open part of the bath is 75x35 mm Bath depth 200 mm Weight 11 kg Power consumption 2.2 kW
Produced in: Tomsk
Aluminum Melting furnace SAT-0.5/7.5
Aluminum Melting furnace SAT-0.5/7.5
from 1 404 420 ₽
Designation SAT-0.5/7.5 Supply voltage, V 380 Installed capacity, kW 42 Temperature stability in steady-state mode, °C ± 5
Produced in: Tula
Chamber electric resistance furnace CHO-6.12.4
Chamber electric resistance furnace CHO-6.12.4
from 550 000 ₽
Designation: SNO-6.12.4 Temperature: 1200 Opendoors: electromechanical Camera size (w.G.V.):600x1200x400 Regulation zones: 1
Produced in: Tula