Metrology

525 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 23
    Areas of use
    Loading...
  • 194
    Item names
    Loading...
  • 53
    Manufacturer
    Loading...
  • 31
    Made in
    Loading...
  • 55
    Additional
    Loading...
View:
525 products
Spectrum Analyzer S4-101
Spectrum Analyzer S4-101
Technical specifications: The operating frequency range of the monitored signals is from 9·103 to 3·109 Hz The analyzer has a zero band and a viewing band in the range from 100 Hz to 3 GHz Limits of permissible error of setting the viewing band ± 1 % The scan range is set from 10 ms to 3000 s in all modes except the zero band of view, and from 20 microseconds to 3000 s in the zero band of view mode The bandwidth of the RFP at the level of minus 3 dB is selected in the range from 100 Hz to 1 MHz in increments of 1, 3, 10 The squareness coefficient of the FPC at the level of minus 60 dB / minus 3 dB is not more than 5:1 The reference level setting range is from plus 30 dBm to minus 100 dBm. Installation step 1 dB Limits of the permissible basic error of setting the reference level ± 1 dB The limits of the unevenness of the amplitude-frequency response (frequency response) of the analyzer in the frequency range from 100 kHz to 3 GHz ± 1 dB Maximum allowable input power is 30 dBm (1 W) Limits of the permissible basic error of measuring the signal level due to the nonlinearity of the logarithmic scale ± 1 dB Limits of the permissible basic error of measuring the signal level due to switching of the input attenuator ± 1 dB Limits of error in measuring the signal level due to switching filters, ± 0.2 dB relative to the 1 kHz filter The average level of intrinsic noise at the FPC bandwidth of 100 Hz, the video filter band of 10 Hz and the input attenuator of 0 dB: - in the range from 100 kHz to 20 MHz minus 75 dBm - in the range from 20 MHz to 1.5 GHz minus 110 dBm - in the range from 1.5 to 3 GHz minus 105 dBm The input impedance of the analyzer is 50 ohms The voltage standing wave coefficient (VSWR) of the input with an input attenuator greater than 10 dB, no more: - 1.5 in the frequency range from 10 MHz to 2.5 GHz - 1.8 in the frequency range from 2.5 GHz to 3 GHz Diagonal screen size 21.5 cm Screen resolution 800x480 USB interface Overall dimensions – 398x220x150 mm Weight not more than 6.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-23
Immitance meter E7-23
Technical specifications: Conductivity (G) - 10-9 – 10 Cm Resistance (R, X, |Z|) - 10-4 – 108 ohms Capacity (S) - 10-14 – 10-1 F Inductance (L) - 10-8 – 104 Gn Q factor (Q), loss angle tangent (tg) 10-3 – 103 Phase angle. shift comp. resistance -180° - +179.9° Leakage current (I) - 10-7 – 10-3 A Measurement error - 0.15 % Operating frequencies – 0.1; 1; 10 kHz (± 0.02%) Measurement levels. signal (SKZ) – 0.04; 1 V The offset voltage on the measured object is 0 – 63 V The output resistance of the source. izmer. signal – 100 ± 20 ohms The time of one measurement is 60, 600 ms, 6 s Power consumption - 20 VA Overall dimensions - 90x265x317 mm Weight - 3.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
High-voltage test installations UPU-21, UPU-21/2
High-voltage test installations UPU-21, UPU-21/2
Technical specifications: Output constant voltage, 0 - 3 kV; 0 - 10 kV Output AC voltage, 0 - 3 kV; 0 - 10 kV Measurement of leakage current, from 0 to 100 Ma The amplitude value of the output voltage ripples relative to the set voltage at a load current of 1 mA, ≤ 5% The error of setting the output voltage, ≤ 4% Protection tripping current, up to 50 mA Output power, 500W Overall dimensions (HxWxD), 280x480x475 mm Weight, 36 kg Operating conditions , Operating temperature, from +5 to + 40 °C Humidity, 80% at 25 °C
MNIPI
Minsk
Produced in: Belarus, Minsk
PKV-IP-11×5.5
PKV-IP-11×5.5
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications the length of the waveguide, mm 11×5.5 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 17.44-25.96 VSWR 1.25
Produced in: Moscow
Laboratory electronic thermometer LTA-NF
Laboratory electronic thermometer LTA-NF
LTA-NF provides an error of ±0.05 °C in the range of measured temperatures from -50 to +200 ° C The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Gas radiometer UDG-03D
Gas radiometer UDG-03D
Installation for continuous measurement and transmission over the information network of the value of the volumetric activity of beta-emitting gases (argon, krypton, xenon). It is used in gas-aerosol control systems at nuclear power and fuel cycle facilities. Purpose: measurement of the volumetric activity of beta-emitting gases (argon, krypton, xenon).
Doza
Zelenograd
Produced in: Moscow
Voltmeters V7-65, V7-65/1, V7-65/2
Voltmeters V7-65, V7-65/1, V7-65/2
Technical specifications: Measuring range 20 mv-1000 V Measurement error ± (0.03% +5 E.M.R.) AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.3% +200 E.M.R. - 4% +800 E.M.R.) Frequency range 20 Hz-100 kHz Direct current Measuring range 1 mA - 2 A Measurement error ± (0.12% +10 E.M.R.) Alternating current Measuring range 10 mA - 2 A Measurement error ± (0.6% +300 E.M.R.) Frequency range 20 Hz - 5 kHz
MNIPI
Minsk
Produced in: Belarus, Minsk
Installation for measuring the volumetric activity of radioactive gases in the air UDG-1B
Installation for measuring the volumetric activity of radioactive gases in the air UDG-1B
Purpose: measurement of the volumetric activity of beta-emitting gases (argon, krypton, xenon). Properties: built-in air flow indicator; compensation for the effects of external gamma background; communication interfaces RS-232, RS-485, Ethernet; sound and light alarm of exceeding the set thresholds; working with your own pumping unit or with an external sampling line; setup using a portable computer; periodic verification without disassembly using an exemplary source; availability of discrete output signal of the device; the possibility of connecting an external emergency alarm unit BAS.
Doza
Zelenograd
Produced in: Moscow
Installation of control of surface contamination of personnel RZBA-09D
Installation of control of surface contamination of personnel RZBA-09D
Complete pollution control with maximum efficiency in minimum time. Easy operation, accessible to employees of any qualification. Purpose: determination of the level of radioactive contamination of the surface of clothing, shoes and leather; measurement of the flux density of beta- and alpha-emitting radionuclides measurement of the surface activity of radionuclides Sr-90+Y-90 and Pu-239; detection of gamma radiation during personnel monitoring; alarm and control of personnel passage when exceeding the set levels.
Doza
Zelenograd
Produced in: Moscow