Metrology

528 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 23
    Applying
    Loading...
  • 196
    Names
    Loading...
  • 54
    Manufacturer
    Loading...
  • 33
    Made in
    Loading...
  • 50
    Additional
    Loading...
View:
528 products
Hydraulic rack TSK-600
Hydraulic rack TSK-600
The hydraulic rack TSK-600 is an automated auxiliary equipment for creating pressure. It is used for checking pressure gauges, pressure transducers, pressure switches and other pressure systems used at the enterprise. The presence of a precision pressure regulator and a built-in amplifier allows a user to create the necessary pressure with a discreteness of 1 kPa easily and accurately. To ensure the operation of the rack in the entire range, it is necessary to have a reference pressure of 0.85 MPa which comes from an external pressure source: a compressor, a KIP air network, a gas cylinder. For operation within the range from 0 to 2.5 MPa, the supply of reference pressure is not required. The TSK-600 hydraulic rack can be manufactured in a version with 2, 3, 4, or 5 stainless steel output ports for setting the reference and verifiable SI. Each output port is equipped with a quick-release adapter with an internal thread M20x1.5 or G1/2, due to which the installation of verifiable SI does not require the use of wrenches. To protect the hydraulic system of the rack from contamination, a replaceable filter of 100 microns is installed in each output port, and the discharge of the working fluid is carried out through a separate discharge line to an external tank. Additionally, the rack can be equipped with measuring channels for checking pressure transmitters and with an alarm unit for ECM. TSK-600 is a unique solution for a metrological laboratory, which makes it possible to facilitate the work of personnel as much as possible and optimize the process of pressure SI verification. Features: • Easy to operate and maintain. • Setting and adjusting the pressure with the movement of one finger. • Multiple output ports for more efficient verification process. • The protection against contamination.
Tekknow
Saint Petersburg
Electronic explosion-proof thermometer ExT-01/2-6
Electronic explosion-proof thermometer ExT-01/2-6
The thermometer sensor ExT-01/2-6 is made in the form of a fully submersible probe with a cable length of 6 meters. The thermometer has an explosion protection marking 0Ex ia IIB T4 Ga X and can be used in explosive zones 0, 1 and 2 of any classes of premises and outdoor installations in which the formation of explosive mixtures of categories IIA, IIB is possible. • Measurement range -50...+130 °C Minimum sensor immersion depth full immersion Overall dimensions of the electronic unit 135x65x40 mm Electronic unit weight 0.3 kg
Produced in: Tomsk
Individual thermoluminescent dosimeters
Individual thermoluminescent dosimeters
The principle of operation of dosimeters is based on the accumulation of ionizing radiation energy by detectors proportional to the radiation dose. In DVG-02TM installations, DOZA-TLD complexes, etc., when the detector is heated, the accumulated energy is released in the form of light radiation, which is recorded by an electronic device.
Doza
Zelenograd
Produced in: Moscow
Installation of control of surface radioactive contamination of personnel RZA-08D
Installation of control of surface radioactive contamination of personnel RZA-08D
Installation for monitoring radioactive contamination of hands, feet (shoes) and clothing of personnel with alpha- and beta - active substances. Modern and intuitive interface, various versions. Purpose: monitoring the level of contamination of hands, feet (shoes) and clothing of personnel with alpha- and beta-active substances and signaling when exceeding permissible levels; measurement of alpha and beta radiation flux density from the surface of the hands, feet (shoes) and clothing of personnel; measurement of the surface activity of alpha- and beta-emitting radionuclides of hands, feet (shoes) and clothing of personnel.
Doza
Zelenograd
Produced in: Moscow
High-temperature smart surface probe L=300 mm SZPVV.300P with built-in flash memory
High-temperature smart surface probe L=300 mm SZPVV.300P with built-in flash memory
from 13 620 ₽
High-temperature smart surface probe L=300 mm SZPVV.The 300P with built-in flash memory is designed to measure the temperature of various materials by directly contacting the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPVV smart probe.300P Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPVV smart probe.300P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Individual gamma and neutron radiation dosimeter DVS-02D
Individual gamma and neutron radiation dosimeter DVS-02D
Purpose: measurement of individual dose equivalent (IED) of mixed gamma-neutron radiation; measurement of individual dose equivalent (IED) of neutron radiation;
Doza
Zelenograd
Produced in: Moscow
PKV-IP-7,2×3,4
PKV-IP-7,2×3,4
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 25.96-37.50 VSWR 1.35
Produced in: Moscow
Mobile radiometric installation UDI-2
Mobile radiometric installation UDI-2
Designed for monitoring radionuclide I-131 in the surface air of the industrial site, sanitary protection zone and monitoring zone of nuclear power plants.
Doza
Zelenograd
Produced in: Moscow
Rubidium frequency standard H1-1013
Rubidium frequency standard H1-1013
Its small dimensions, weight, power consumption, and operating time allow it to be widely used as an embedded source of high-stability signals in frequency measuring devices and complexes, telecommunications systems, navigation and communication systems.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod