Installation radiometric UDGB-01
Installation radiometric UDGB-01
The installation provides continuous measurement, indication on the built-in indicator and transmission over the information network of the value of the volumetric activity of radioactive gases, including tritium and carbon-14. The detection units of the installation can be either built-in or remote. The installation is available in three versions: UDGB-01T, UDGB-1T1, UDGB-01T2, differing in metrological characteristics and design features. Purpose: measurement of the volumetric activity of beta-emitting inert gases (argon, krypton, xenon), as well as gases containing tritium and carbon-14 in the air of working rooms and ventilation systems.
Doza
Zelenograd
Produced in: Moscow
 Electronic Stopwatch-Meter IVPR-203M
Electronic Stopwatch-Meter IVPR-203M
from 30 940 ₽
The electronic stopwatch - time parameter meter IVPR-203M is a universal small-sized device of a new type for monitoring and measuring the time parameters of relays, switches and switches of electrical equipment, relay protection, automation and telemechanics.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Installation radiometric UDGP-01
Installation radiometric UDGP-01
The installation provides determination of volumetric activities of gamma-emitting radionuclides in various technological media (for example, liquids, pulps and vapors in pipes) and transmission of spectrometric information over a local network. Purpose: measurement of the volumetric activity of gamma-emitting radionuclides in technological environments; identification of leaky steam generators and monitoring of the volumetric activity of gamma-emitting radionuclides in the acute steam of the second circuit of nuclear power plants (VVR-440, 1000) according to the control method developed by VNIIAES.
Doza
Zelenograd
Produced in: Moscow
Portable electrical Laboratory for testing and finding cable damage by acoustic and induction method Athlete KAI-2.502 (IDM)
Portable electrical Laboratory for testing and finding cable damage by acoustic and induction method Athlete KAI-2.502 (IDM)
Appointment Athlete KAI-2.502 (IDM) • Search for a live cable. • Detection of the location of the passage of hidden communications. • Preliminary detection of the distance to the place of damage. • Search for places of cable damage in an acoustic way. • Search for places of cable damage by electromagnetic means. • Cable insulation testing. • The "Friend-Foe" mode.
Produced in: Kolomna, Moscow region
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-4
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-4
Tracing a cable line. Burning of defective cable insulation with subsequent afterburning of it. Troubleshooting of cable lines by induction method. Troubleshooting of cable lines by acoustic method. Insulation testing of power cables and solid dielectrics.
Produced in: Kolomna, Moscow region
Gamma and X-ray radiation dosimeter DKG-09D "Chizh"
Gamma and X-ray radiation dosimeter DKG-09D "Chizh"
Purpose: measurement of the ambient dose equivalent of gamma and continuous X-ray (photon) radiation N *(10); measurement of the ambient dose equivalent of gamma and continuous X-ray (photon) radiation N *(10).
Doza
Zelenograd
Produced in: Moscow
Electronic explosion-proof thermometer ExT-01/2-15
Electronic explosion-proof thermometer ExT-01/2-15
The thermometer sensor ExT-01/2-15 is made in the form of a fully submersible probe with a cable length of 15 meters. The thermometer has an explosion protection marking 0Ex ia IIB T4 Ga X and can be used in explosive zones 0, 1 and 2 of any classes of premises and outdoor installations in which the formation of explosive mixtures of categories IIA, IIB is possible. • Measurement range -50...+130 °C Minimum sensor immersion depth full immersion Overall dimensions of the electronic unit 135x65x40 mm Electronic unit weight 0.3 kg
Produced in: Tomsk
HUMAN RADIATION SPECTROMETER SKG‑AT1316A
HUMAN RADIATION SPECTROMETER SKG‑AT1316A
Deliveries in the CIS are carried out by LLC NPP RADIKO 249035, Kaluga region, Obninsk, Marx Avenue, 14 Phone: 8(48439) 4-97-16, 4-97-18 / Fax: 8(48439) 4-97-68 E-mail: main@radico.ru / Web site: http://www.radico.ru Control of exceeding the threshold value of the total activity of radionuclides 51Cr, 54Mn, 58Co, 59Fe, 65Zn, 95Nb, 100mAg, 103Ru, 124Sb, 141Ce, 144Ce in the lungs; Flexible software control of the spectrometer functions, the formation of a database and a report on the results of the survey Express control capacity - 15 people per hour The possibility of sharing AT1316(AT1316A) and AT1322(AT1322/1) The possibility of accommodation in a minibus as part of a mobile radiation control laboratory
Produced in: Belarus, Minsk
UNM-2000/6000 portable magnetizing device
UNM-2000/6000 portable magnetizing device
The principle of operation of the means of magnetic particle control The portable device UNM-2000/6000 of the MANUL series is a magnetic particle flaw detector that provides measurements by the applied field method and the residual magnetization method using direct, alternating and pulsed current with specified parameters. External magnetizing devices included in the kit (solenoids, electromagnets, contact devices for connecting cables) allow for longitudinal, transverse and circular magnetization of the object under study. A special magnetic powder, dry or in the form of an emulsion, is applied to the controlled surface. Inhomogeneities of the magnetic field in the places of defects lead to the accumulation of powder particles, thus "showing" a hidden picture. Design features and advantages of the UNM-2000/6000 powder flaw detector: In the MANUL series, the UNM-2000/6000 device is capable of providing the highest magnetization current (up to 6000 A in pulse mode), which allows you to control products having a large mass or size, as well as those made of magnetohard alloys; The device can be included in automated quality control stands: there are network interfaces (LAN, Bluetooth, Wi-Fi) for connection; microprocessor control provides storage and reproduction of magnetization and demagnetization parameters, logging of control results, automatic demagnetization; The design is modular, allows for changes to implement the individual wishes of the customer; It fully complies with the following standards: GOST R 56512-2015, GOST R 53700-2009 (ISO 9934-3:2002), GOST R 50.05.06-2018, GOST R ISO 10893-5-2016, GOST ISO 17638-2018 , RD 34.17.102-88, RD-13-05-2006 and other Russian and foreign standards regarding the requirements for magnetizing devices and magnetic particle flaw detectors; It is approved for use by industry regulatory documents, in particular, by the Russian Railways. Scope of application Magnetic powder control devices are widely used in various industries, construction and transport, from steel and pipe rolling plants to organizations engaged in the operation and repair of machines, mechanisms and vehicles. Magnetic powder flaw detectors belong to the means of non-destructive testing and therefore can be used to detect defects in products and structures operating under pressure, including at chemical and oil and gas industry enterprises, as well as during the operation of pipelines. In particular, devices for monitoring by the magnetic powder method have proven themselves well at Russian Railways and metro enterprises engaged in the operation and repair of rolling stock, including for the control of shafts, wheels and wheel pairs, gearboxes, springs, couplers and other loaded components and parts. Technical specifications: Magnetization currents: Variable, Pulse, Rectified (only for solenoid and electromagnet) The measurement error of the magnetization current is no more than 10%. Characteristics of the pulse current: The repetition frequency of unipolar current pulses during magnetization and of multipolar current pulses during demagnetization is (2 ± 0.2) Hz. The duration of the current pulses is at least 1.5 ms. Magnetic characteristics of the solenoid: The maximum alternating magnetic field in the center of a single solenoid is at least 100 A/cm. The maximum alternating magnetic field on the axis in the center between two solenoids located at a distance of 200 mm is at least 60 A/cm. The maximum permanent magnetic field in the center of a single solenoid is at least 80 A/cm. The maximum permanent magnetic field on the axis in the center between two solenoids located at a distance of 200 mm is at least 50 A/cm. Values of magnetization currents: The maximum alternating magnetization current in the unwound cable is 6 m × 50 mm2 and on the electrical contacts is at least 2000 A. The maximum pulse magnetization current in an unwound cable of 4 m × 10 mm2 and on electrical contacts is at least 6000 A. The current adjustment range in the solenoids and the electromagnet is from 0.5 to 4.5 A. Characteristics of the electromagnet: The maximum alternating magnetic field in the air gap of the electromagnet depending on the interpolar distance is as follows: - in the 140 mm gap: at least 75 A/cm; - in the 40 mm gap: at least300 A/cm. The maximum constant magnetic field in the air gap of the electromagnet depending on the interpolar distance is as follows: - in the 140 mm gap: at least 100 A/cm; - in the 40 mm gap: at least 400 A/cm. Operating mode: The operating mode is cyclic: magnetization/pause. The magnetization time is adjustable from 1 to 40 s. The demagnetization time is adjustable from 5 to 60 seconds. Demagnetization of parts is performed automatically. The time of setting the operating mode is no more than 15 seconds. The duration of continuous operation is at least 8 hours. Power supply parameters: The device is powered by an AC power supply with a voltage of 220 V and a frequency of 50 Hz. The power consumed from the network is no more than 5 kVA. Overall characteristics: Overall dimensions of the device (w × h × d) – no more than 267×245×465 mm. The weight of the device is not more than 50 kg. Other characteristics: The average worktime before failure is at least 12500 hours. The average recovery time is no more than 6 hours. The average service life of the device is at least 10 years. Сompliance with standards The device fully complies with the requirements of GOST R 56512-2015, GOST R 53700-2009 (ISO 9934-3:2002), GOST R 50.05.06-2018, GOST R ISO 10893-5-2016, GOST ISO 17638-2018, RD 34.17.102-88 and RD-13-05-2006 in terms of the requirements for magnetizing devices and magnetic particle flaw detectors. Identification of the load. It performs automatic identification of the types of connected load: cables, solenoids and electromagnet. Control of the connected load current It allows you to control the current of the connected AC/DC electromagnets and solenoids. The kit includes: 1 Electrical contact with cable, cross section 50 mm2, length 3m 2 Solenoid cable, 3m long 3 Solenoid cable, 0.5m long 4 Magnetizing cable, cross section 10 mm2, length 6m 5 Magnetizing cable, cross section 50 mm2, length 6m 6 Solenoid - 2pcs 7 The electromagnet is manual 8 Trolley 9 Power unit UNM 2000/6000
Produced in: Moscow