Installation of control of surface radioactive contamination of personnel RZBA-08D
Installation of control of surface radioactive contamination of personnel RZBA-08D
Installation for monitoring radioactive contamination of hands, feet (shoes) and clothing of personnel with beta-, gamma- and alpha-active nuclides, convenient and intuitive interface, various versions. Purpose: monitoring the level of contamination of hands, feet (shoes) and clothing of personnel with beta-, gamma- and alpha-emitting radionuclides and signaling when exceeding permissible levels; measurement of beta and alpha radiation flux density from the surface of the hands, feet (shoes) and clothing of personnel; measurement of surface activity of alpha- and beta-emitting radionuclides of hands, feet (shoes) and clothing of personnel; measurement of the ambient dose equivalent (MAED) power of gamma radiation.
Doza
Zelenograd
Produced in: Moscow
Smart submersible probe L=150 mm SZPG.150PM (d=2 mm) with built-in flash memory
Smart submersible probe L=150 mm SZPG.150PM (d=2 mm) with built-in flash memory
from 10 560 ₽
The smart submersible probe L=150 mm SZPG.150PM (d=2 mm) with built-in flash memory is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor, Android program. Operating conditions of the SZPG.150PM smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPG.150PM smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Calibration capability.
Produced in: Kolomna, Moscow region
Smart air probe L=500 mm SSV.500P with built-in flash memory
Smart air probe L=500 mm SSV.500P with built-in flash memory
from 11 520 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object. The smart air probe L=500 mm SSV.500P with built-in flash memory is designed to measure the temperature of various media by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor. Android program is installed. Operating conditions of the SZV.500P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSV.500P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect external power. Possibility of calibration.
Produced in: Kolomna, Moscow region
Pressure gauge MTIf-250
Pressure gauge MTIf-250
It is designed for the use with Raid bombs BR 01T, BR 02T in determining the absolute vapor pressure of volatile crude oil and volatile non-viscous petroleum products in accordance with GOST 1756. Pressure gauge with a range of measured pressure 0...250 kPa. Accuracy class 0.4 Connection size M20x1.5 mm Overall dimensions 160 mm Weight 1.5 kg
Produced in: Tomsk
High-frequency signal generator G4-230
High-frequency signal generator G4-230
The generator is capable of operating both autonomously and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range from 5 to 17.85 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main output is from minus 110 to 13 dBm The basic error of setting the reference power level is ± 1.0 dB Instability of the output signal power level for any 15-minute time interval of no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal: low frequency from 1 Hz to 20 kHz RFM from 10 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value): low frequency from 1 Hz to 100 kHz RFM from 50 to 10000 kHz - the main error of the frequency deviation setting is ± (3 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the main error in setting the amplitude modulation coefficient: Internal ± (0.15M + 0.2)% External ± (0.20M + 0.5)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 15 kg
Produced in: Moscow
High-precision cmart surface probe L =500 mm SZPWT.500P with built-in flash memory
High-precision cmart surface probe L =500 mm SZPWT.500P with built-in flash memory
from 14 580 ₽
High-precision cmart surface probe L =500 mm SZPWT.500P with built-in flash memory is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPVT smart probe.500P Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPVT smart probe.500P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Installation of control of surface contamination of personnel RZBA-09D
Installation of control of surface contamination of personnel RZBA-09D
Complete pollution control with maximum efficiency in minimum time. Easy operation, accessible to employees of any qualification. Purpose: determination of the level of radioactive contamination of the surface of clothing, shoes and leather; measurement of the flux density of beta- and alpha-emitting radionuclides measurement of the surface activity of radionuclides Sr-90+Y-90 and Pu-239; detection of gamma radiation during personnel monitoring; alarm and control of personnel passage when exceeding the set levels.
Doza
Zelenograd
Produced in: Moscow
Frequency comparator Ch7-1015
Frequency comparator Ch7-1015
Since it is reliable and easy to operate, the device is widely used in metrological centers, measuring laboratories, at the workplaces of REA developers. The memory of the comparator Ch7-1015 contains information about the main technical characteristics of domestic and foreign rubidium frequency standards presented on the Russian market, which greatly simplifies the process of checking devices in calibration laboratories. The device has a USB 2.0 communication interface with an external personal computer and application software for an external PC. The comparator Ch7-1015 has the ability to remotely control all modes of operation via a TCP protocol streaming socket and can work within an automated system.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Spectrum Analyzer S4-101
Spectrum Analyzer S4-101
Technical specifications: The operating frequency range of the monitored signals is from 9·103 to 3·109 Hz The analyzer has a zero band and a viewing band in the range from 100 Hz to 3 GHz Limits of permissible error of setting the viewing band ± 1 % The scan range is set from 10 ms to 3000 s in all modes except the zero band of view, and from 20 microseconds to 3000 s in the zero band of view mode The bandwidth of the RFP at the level of minus 3 dB is selected in the range from 100 Hz to 1 MHz in increments of 1, 3, 10 The squareness coefficient of the FPC at the level of minus 60 dB / minus 3 dB is not more than 5:1 The reference level setting range is from plus 30 dBm to minus 100 dBm. Installation step 1 dB Limits of the permissible basic error of setting the reference level ± 1 dB The limits of the unevenness of the amplitude-frequency response (frequency response) of the analyzer in the frequency range from 100 kHz to 3 GHz ± 1 dB Maximum allowable input power is 30 dBm (1 W) Limits of the permissible basic error of measuring the signal level due to the nonlinearity of the logarithmic scale ± 1 dB Limits of the permissible basic error of measuring the signal level due to switching of the input attenuator ± 1 dB Limits of error in measuring the signal level due to switching filters, ± 0.2 dB relative to the 1 kHz filter The average level of intrinsic noise at the FPC bandwidth of 100 Hz, the video filter band of 10 Hz and the input attenuator of 0 dB: - in the range from 100 kHz to 20 MHz minus 75 dBm - in the range from 20 MHz to 1.5 GHz minus 110 dBm - in the range from 1.5 to 3 GHz minus 105 dBm The input impedance of the analyzer is 50 ohms The voltage standing wave coefficient (VSWR) of the input with an input attenuator greater than 10 dB, no more: - 1.5 in the frequency range from 10 MHz to 2.5 GHz - 1.8 in the frequency range from 2.5 GHz to 3 GHz Diagonal screen size 21.5 cm Screen resolution 800x480 USB interface Overall dimensions – 398x220x150 mm Weight not more than 6.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
EVRAZ HYDRO Submersible probe For measuring the hydrogen content in steel
EVRAZ HYDRO Submersible probe For measuring the hydrogen content in steel
Purpose: Measurement of hydrogen in molten metals Scope of application: Induction furnaces, ladle furnace units, vacuum cleaners, casting ladles of various types, intermediate ladles, crystallizers Measuring range: from 0.5 to 14 ppm H2 Accuracy: 0.5 to 3ppm - 0.1ppm H2 3.0 to 14ppm - 3% H2 Measurement time: up to 60 seconds Reproducibility of results: 0.3% Purpose: Measurement of the percentage of carbon in steel Scope of application: Furnaces, buckets, cupola furnace Measuring range: 0.01 to 2.00% carbon Accuracy: 0.01 %
Produced in: Lipetsk
Smart surface  probe  high temperature L=1000 mm SZPVV.1000P with built-in flash memory
Smart surface probe high temperature L=1000 mm SZPVV.1000P with built-in flash memory
The smart surface probe high-temperature L=1000 mm SZPVV.1000P with built-in flash memory is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor, Android program. Operating conditions of the SZPVV.1000P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPVV.1000P smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region