Doza

Doza

62 products
View:
Telephone number:
Website: www.doza.ru
Address:
Russia, Zelenograd, 5, floor 2, 49
Website: www.doza.ru
Address:
Russia, Zelenograd, 5, floor 2, 49
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 5
    Applying
  • 18
    Names
    Loading...
  • 1
    Manufacturer
  • 1
    Made in
  • 4
    Additional
View:
56 products
Installation for measuring the parameters of the air flow multichannel USPVM
Installation for measuring the parameters of the air flow multichannel USPVM
The installation is intended for use in gas-aerosol emission control systems in order to determine the volumetric air flow in ventilation systems by measuring the linear air flow velocity at local points of the dimensional section, as well as for measuring air temperature and humidity at local points. The measuring system of the installation complies with GOST 12.3.018-79 (SSBT. Ventilation systems. Methods of aerodynamic tests).
Doza
Zelenograd
Produced in: Moscow
Multifunctional UKRV-2 air flowmeter
Multifunctional UKRV-2 air flowmeter
Purpose: measurement of the volume of air pumped through the analytical filter; measurement of volumetric air flow through an analytical filter. Features: output of information to the LCD indicator; automatic and manual control of an external actuator (valve, crane); obtaining information about the analytical filter used using a barcode reader; transmission of data on the state of the device, the measured volume flow and the pumped volume of air to communication channels; providing access to information via the RS-485 interface; work both independently and as part of radiation monitoring systems
Doza
Zelenograd
Produced in: Moscow
Dosimetric thermoluminescent complex "DOSE-TLD"
Dosimetric thermoluminescent complex "DOSE-TLD"
Purpose: measurement of the individual dose equivalent of Hp(10) photon radiation; measurement of the individual dose equivalent of Hp(10) neutron radiation; measurement of the individual dose equivalent in the skin Hp(0.07) and the lens of the eye Hp(3) of photon and beta radiation; measurement of ambient dose equivalent H*(10) of photon radiation.
Doza
Zelenograd
Produced in: Moscow
Individual thermoluminescent dosimeters
Individual thermoluminescent dosimeters
The principle of operation of dosimeters is based on the accumulation of ionizing radiation energy by detectors proportional to the radiation dose. In DVG-02TM installations, DOZA-TLD complexes, etc., when the detector is heated, the accumulated energy is released in the form of light radiation, which is recorded by an electronic device.
Doza
Zelenograd
Produced in: Moscow
Installation of control of surface radioactive contamination of personnel RZA-08D
Installation of control of surface radioactive contamination of personnel RZA-08D
Installation for monitoring radioactive contamination of hands, feet (shoes) and clothing of personnel with alpha- and beta - active substances. Modern and intuitive interface, various versions. Purpose: monitoring the level of contamination of hands, feet (shoes) and clothing of personnel with alpha- and beta-active substances and signaling when exceeding permissible levels; measurement of alpha and beta radiation flux density from the surface of the hands, feet (shoes) and clothing of personnel; measurement of the surface activity of alpha- and beta-emitting radionuclides of hands, feet (shoes) and clothing of personnel.
Doza
Zelenograd
Produced in: Moscow
Individual gamma and neutron radiation dosimeter DVS-02D
Individual gamma and neutron radiation dosimeter DVS-02D
Purpose: measurement of individual dose equivalent (IED) of mixed gamma-neutron radiation; measurement of individual dose equivalent (IED) of neutron radiation;
Doza
Zelenograd
Produced in: Moscow
Mobile radiometric installation UDI-2
Mobile radiometric installation UDI-2
Designed for monitoring radionuclide I-131 in the surface air of the industrial site, sanitary protection zone and monitoring zone of nuclear power plants.
Doza
Zelenograd
Produced in: Moscow
X-ray Radiation Dosimeters Clinical DRC
X-ray Radiation Dosimeters Clinical DRC
X–ray radiation dosimeters clinical DRC, depending on the modification, are designed for: measuring the product of the kerma (absorbed dose) in the air by the cross-sectional area of the X-ray beam (hereinafter referred to as the product of the kerma in the air by the area) when using the DRC-1, DRC-1E, DRC-1M Outline, DRC-1M dosimeters with the DRC measuring console-1M-E03, DRC-1M-E04, DRC-1M-E05, DRC-1M-E06; measurements of the product of the kerma power (absorbed dose) in the air per area (hereinafter referred to as the product of the kerma power in the air per area) using the DRK–1E and DRK-1M dosimeters equipped with the DRK-1M-E06 measuring console; measurements of the product of the kerma (absorbed dose) in the air along the length (hereinafter referred to as the product of the kerma in the air along the length) using DRK-1M-CT dosimeters; measurements of kerma (absorbed dose) in the air; measurements of the kerma power (absorbed dose) in the air when using DRK-1M dosimeters.
Doza
Zelenograd
Produced in: Moscow
Filter holder FD-1D
Filter holder FD-1D
The filter holder is designed to install an aerosol filter of the AFA type in it. It is used in sampling systems of gas-aerosol media at radiation-hazardous and other production facilities.
Doza
Zelenograd
Produced in: Moscow
Installation radiometric UDGB-01
Installation radiometric UDGB-01
The installation provides continuous measurement, indication on the built-in indicator and transmission over the information network of the value of the volumetric activity of radioactive gases, including tritium and carbon-14. The detection units of the installation can be either built-in or remote. The installation is available in three versions: UDGB-01T, UDGB-1T1, UDGB-01T2, differing in metrological characteristics and design features. Purpose: measurement of the volumetric activity of beta-emitting inert gases (argon, krypton, xenon), as well as gases containing tritium and carbon-14 in the air of working rooms and ventilation systems.
Doza
Zelenograd
Produced in: Moscow
DRK-1M X-ray Dosimeter
DRK-1M X-ray Dosimeter
Purpose determination of the effective dose of patients in radiation diagnostics; control of stability of parameters of X-ray machines
Doza
Zelenograd
Produced in: Moscow
Droplet separator
Droplet separator
The drip collector is designed to remove droplet moisture when sampling air from indoor ventilation systems and is installed in gas aerosol sampling systems. Purpose: removal of droplet moisture from the selected air sample; accumulation of droplet moisture; indication of the level of accumulated moisture; draining the accumulated moisture.
Doza
Zelenograd
Produced in: Moscow