UCHX2-37
UCHX2-37
Basic properties: Wide frequency range; Sufficiently large output power; High level of suppression of side harmonics of the input signal; Low value of phase noise; Relatively simple technical solutions: - synchronization and frequency stabilization, - stabilization and adjustment of the output power level, - implementation of amplitude and frequency modulation modes; Do not require external bias diodes. Operating conditions: Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical characteristics Input/output frequency range, GHz 12,93-18,75 / 25,86-37,5 Losses (max.), dB 13 Input power level, dBm 15-21 Unevenness of output power (Rvh. = 20 dBm), dB ± 1.5 The level of parasitic harmonics of the input signal at the output (min.), dBn 20 Output VSWR (max.) 2.0 Connector type: • Input Coax. 3.5/1.5 mm (socket) • Output Waveguide 7.2x3.4 mm Overall dimensions, mm 29x24x24 Weight, g 60
Produced in: Moscow
Drying cabinet LF-60/350-GG1
Drying cabinet LF-60/350-GG1
Design features: Microprocessor temperature controller; Four-sided heating; Natural air convection in the working chamber; The material of the chamber is steel painted with heat–resistant paint; Bright LED display; Conveniently located control panel; LED indicators of heater operation and protection operation; Alarm when the current temperature exceeds the limits of the permissible range; Reliable door closing mechanism; High-quality silicone sealer; Highly efficient thermal insulation of the housing; The case is made of high-quality sheet steel and painted with heat-resistant powder paint; Number of shelves: standard – 2, maximum – 6. Technical specifications: Maximum heating temperature, °C +350 The error of reproducing the set temperature ° C ± 5 Temperature maintenance error, ° C ± 2 Warm-up time to the maximum temperature, no more, min 45 Dimensions of the working chamber, (WxHxD), not less than mm 340x400x415 Overall dimensions, (WxHxD), not more than 685x580x670 mm Rated supply voltage, 220 V Rated power, W 2200
LOIP
Saint Petersburg
Produced in: Saint Petersburg
2NVR-5DM1 Rotary vane vacuum pump
2NVR-5DM1 Rotary vane vacuum pump
The 2NVR-5DM1 rotary vane vacuum pump is manufactured in the climatic version of UHL 4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). It meets the requirements of technical specifications TU 3648-006-00218526-2002. It is designed and manufactured taking into account the requirements of GOST R 52615-2006. Electricity grid must meet the requrimemnts of GOST 32144-2013
Produced in: Kazan
Automatic apparatus ATK-LAB-12 for determining the temperature of crystallization (freezing) by laser method
Automatic apparatus ATK-LAB-12 for determining the temperature of crystallization (freezing) by laser method
The parameters of accuracy, convergence and reproducibility are equivalent and correlate with the result obtained in accordance with manual methods ASTM D2386, GOST R 52332-2005, GOST 5066-91, ISO 3013, IP 16 The device is designed taking into account all the requirements of the standards for testing and is equipped with a built-in cooling system that allows the test cell to cool down to -100 ° C, without requiring external cooling. • Sample temperature detection range -100...25 °C Accuracy of determination of sample temperature ± 0.1 °C The temperature range of the test chamber is -100...30 °C The volume of the analyzed sample is 10 ± 2 ml Power consumption from the mains 220, not more than 250 watts USB, LAN interface Overall dimensions (WxHxD), not more than 250x450x360 mm Weight, not more than 12 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
MARK-5010 Hydrogen Purity Analyzer
MARK-5010 Hydrogen Purity Analyzer
High-precision measurements of hydrogen concentration in the range of 95-100% Monitoring of the operation of electrolyzers, control of hydrogen purity in the processes of hydrogen cooling of generators, in the technological processes of chemical, petrochemical, metallurgical and other industries 24 months warranty for deliveries across the Russian Federation A new patented measurement method The device does not require calibration Selectivity of measurement Direct method of measuring molecular hydrogen Insensitivity to humidity, carbon dioxide, oil vapor Measurement time 3-5 min Simple, intuitive interface Minimum maintenance Self-diagnosis Routine maintenance no more than 1 time per year Long-lasting, highly stable sensor The service life of the sensor is at least 10 years Color touch screen
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod, Moscow
MM-180/20/35 POZIS Medical freezer
MM-180/20/35 POZIS Medical freezer
from 58 660 ₽
Refrigerant 404a Total volume, l. 180 The volume of the freezer / NTO, l. 180 Number of compressors, pcs. 1 Height, mm 870 Height with wheels, mm 940 Depth, mm 720 Width, mm 1310 Weight, kg., no more 80,5 Rated power consumption, W 250 Maximum rated power, W 275 Voltage, 220 V Warranty, 1 year Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Freezer compartment The temperature in the freezer, °C -18...-40 Thermal card: yes Efficiency and energy consumption Electricity consumption at t storage -18°C and t roc +25°C, kWh/day, no more than 0.81 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 80,5 Gross weight of the product, kg 93.5 Volume of packaging, m3 0,965 The length of the package, m 0,75 Width of the package, m 1.34 Height of the package, m 0.96
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
IR Laser Module KLM-D980-x-5 980nm
IR Laser Module KLM-D980-x-5 980nm
from 4 314 ₽
Laser modules of the KLM-D980-x-5 series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
CRYO-VT-11 Low-temperature liquid thermostat
CRYO-VT-11 Low-temperature liquid thermostat
It is designed to maintain the set temperature of the coolant circulating in the internal bath of the thermostat and in the connected external consumers. Feed pump for external closed-type thermostating systems. Cooling capacity 300 W at +20 °C. An internal bath with a volume of 17 liters and a depth of 250 mm. Operating temperature range -30...+100 °C. Overall dimensions 400x690x585 mm The open part of the bath is 140x190 mm Bath depth 250 mm Weight 50 kg Power consumption 3.5 kW.
Produced in: Tomsk
Copper Transceiver SFP 10/100/1000Base-T
Copper Transceiver SFP 10/100/1000Base-T
from 2 175 ₽
Receiving and transmitting modules for electrical communication lines in SFP metal cases with separate optical input/output for an RJ-45 type electrical connector to transmit the signal over two optical fibres.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Laboratory vacuum drying cabinets SHSV residual pressure in the chamber 10 mm Hg SHSV-65/3,5
Laboratory vacuum drying cabinets SHSV residual pressure in the chamber 10 mm Hg SHSV-65/3,5
The electric vacuum drying cabinet SHSV-65/3.5 is designed for drying and heating various materials in air and in vacuum at a maximum temperature of 350 ° C. In the model with the index "C", the door is made of heat- resistant glass. Technical specifications The electric cabinet operates at ambient temperature from 10 to 35 ° C and relative humidity up to 80% at 25 ° C Operating temperature- 350 ⁰C Power consumption - 2500 W Dimensions of the working chamber-Ø430x430 mm Dimensions WxDxH- 620x950x670 mm Weight - 90* kg (* - mass with microprocessor unit and pump)
MIUS
Tula
Produced in: Tula
SRK‑AT2327 ALARM METER
SRK‑AT2327 ALARM METER
Building a flexible and reliable multi-channel system Independent measurements on each channel in a wide range of gamma and neutron radiation dose rates and neutron and beta particle flux densities Audiable and light alarms High reliability and self-control Software that allows you to display on the PC monitor the current radiation situation in the controlled area Data logging Backup power supply The possibility of integration with external security systems
Produced in: Belarus, Minsk
Analytical scales VL-224V-S
Analytical scales VL-224V-S
from 217 490 ₽
Technical characteristics: NIP, G220 Discreteness, g0,0001 Calibration,self-calibration The smallest weighing limit, g0.01 Diameter of the scale bowl, mm91 The price of the verification scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ±1.0; sv 200 to 220g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, seconds, no more - fast mode - 2; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x213x338 Weight of the scales, kg, not more than 6.2 Adjustment weight built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg