Central Heating Unit N (CHU-N) Kit
Central Heating Unit N (CHU-N) Kit
It is designed to control the excess pressure during the crimping of pipelines before putting them into operation, as well as during scheduled system health checks. The devices are registered in the State Register of Measuring Instruments for No. 30414-11, No. 43646-10 and are approved for use in the Russian Federation. Features of the CHU-N kit Carrying out pressure testing before the start of commissioning allows you to identify possible defects in seams and pipes, ensuring their tightness and reliability of insulation. The kit is designed to work in the field in order to record and archive the measured results to identify possible defects. The CHU-M kit is a portable complex with autonomous power supply.
Produced in: Kolomna, Moscow region
Fischer coulometric Titrator
Fischer coulometric Titrator
from 690 000 ₽
The Fischer titrator is designed to measure the moisture content in non-aqueous media in substances that do not interact with the Fischer reagent, such as petroleum, petroleum products, oils (transformer, turbine, hydraulic, motor, etc.), organic solvents, etc. in accordance with GOST ISO 12937:2000, GOST 24614-81, GOST 33733-2016, GOST R 54284-2010, GOST R IEC 60814, GOST 14870-77, ASTM D 4928-00 (2010), ASTM D6304-07, ASTM D 1533-00, ASTM E 1064-05.
EKROSKHIM
Saint Petersburg
Produced in: Saint Petersburg
Smart surface  probe  high temperature L=1000 mm SZPVV.1000P with built-in flash memory
Smart surface probe high temperature L=1000 mm SZPVV.1000P with built-in flash memory
from 18 078 ₽
The smart surface probe high-temperature L=1000 mm SZPVV.1000P with built-in flash memory is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor, Android program. Operating conditions of the SZPVV.1000P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPVV.1000P smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Dosimetric installations "Gamma sensor"
Dosimetric installations "Gamma sensor"
Appointment: Measurement of the ambient dose equivalent (MAED) power of gamma radiation during radiation reconnaissance and operational control of radioactive contamination of the area. Installations can be installed on cars and other mobile means, except for air.
Doza
Zelenograd
Produced in: Moscow
Generators G4-221, G4-221/1
Generators G4-221, G4-221/1
Technical specifications: Frequency range of sinusoidal waveforms, 0.1 Hz - 17 MHz Frequency range of rectangular-shaped signals, 0.1 Hz - 1 MHz Frequency setting discreteness, ±(0.012 + 0.0001 f), f in Hz Frequency instability in 15 minutes, no more than ± 1•10-5 Smooth signal attenuation, 40 dB Stepwise signal attenuation, 20, 40, 60 dB
MNIPI
Minsk
Produced in: Belarus, Minsk
Wide-aperture low-temperature noise generator PNSHI200
Wide-aperture low-temperature noise generator PNSHI200
Designed for: measurements of the reference measure of the noise temperature unit of nominal values (81 ± 2) K and (293 ± 10) K in the frequency range from 2 to 40 GHz.
VNIIFTRI
Mendeleevo
Produced in: Mendeleevo, Moscow region
Universal frequency meter Ch3-89
Universal frequency meter Ch3-89
The frequency meter is able to work both independently and as part of automated measuring systems with interfaces such as USB or RS-232. Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 150 MHz Frequency of video pulse signals (inputs A, B) 0.001 Hz - 100 MHz Frequency of continuous sinusoidal oscillations (input C) (0.1 - 1) GHz Frequency of continuous sinusoidal oscillations (input D) (1 - 37.5) GHz Carrier frequency of a continuous signal with frequency modulation (FM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz-100 kHz; frequency deviation from 10 kHz to 10 MHz Carrier frequency of a continuous signal with amplitude modulation (AM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz - 100 kHz; AM factor up to 100% Carrier frequency of a continuous radio pulse sequence (IM) signal (input D) Fn = (1-37.5) GHz, from 0.15 microseconds to 1ms, Fsl from 100 Hz to 3 MHz, from 2 to 103 Pulse duration 10 ns – 0.1 s Time interval from -10 to 10 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Phase difference of two synchronous sinusoidal signals from minus 360° to 360° The measurement error of the phase difference of two synchronous sinusoidal signals is ± 0.36° (from 1 kHz to 1 MHz) ± 3.6° (above 1 MHz) Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 7.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) (0.03 - 1.0) V •for sinusoidal and IM signals (input D) 10 MW (from 1 to 8 GHz); 40 MW (sv. 8 to 18 GHz); 50 MW (sv. 18 to 37.5 GHz). The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 100 VhA Overall dimensions, mm 496x174x459 Weight, not more than 16 kg
Produced in: Moscow
IPA-01 Wearable Sampler
IPA-01 Wearable Sampler
from 20 000 ₽
Determination of the integral concentration of radioactive aerosols in the personnel breathing area (exposure time 8 hours) by radon (thoron) daughter products and long-lived radionuclides in accordance with the requirements of NRB-99 and OSPORB-99. Automatic stabilization of the air sampling rate. (It is possible to supply additional consumables to IPA - 01)
Produced in: Moscow
Installation for measuring the volumetric activity of radioactive gases in the air UDG-1B
Installation for measuring the volumetric activity of radioactive gases in the air UDG-1B
Purpose: measurement of the volumetric activity of beta-emitting gases (argon, krypton, xenon). Properties: built-in air flow indicator; compensation for the effects of external gamma background; communication interfaces RS-232, RS-485, Ethernet; sound and light alarm of exceeding the set thresholds; working with your own pumping unit or with an external sampling line; setup using a portable computer; periodic verification without disassembly using an exemplary source; availability of discrete output signal of the device; the possibility of connecting an external emergency alarm unit BAS.
Doza
Zelenograd
Produced in: Moscow
Voltmeters B7-91, B7-91/1
Voltmeters B7-91, B7-91/1
Technical specifications: DC voltage , Measuring range, 10 MV - 1000 V Measurement error, ± 0.03% AC voltage , Measuring range, 1 mV - 750 V Measurement error, ± 0.4% Frequency range, 20 Hz- 100 kHz Direct current , Measuring range, 1 mkA - 2 A (B7-91/1) Measuring range, 1 mkA - 20 A (B7-91) Measurement error, ± 0.03%
MNIPI
Minsk
Produced in: Belarus, Minsk