Equipment

2285 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 394
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 91
    Additional
    Loading...
View:
2285 products
EVRAZCOMB – 3 in 1
EVRAZCOMB – 3 in 1
Purpose: Measurement of temperature, oxygen activity and sampling of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measuring range: from 1 to 2000 ppm O - metal oxidation from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the oxygen activity level) The shape of the selected metal shape: Circle: thickness 12 mm Oval: thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other length is possible on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
Produced in: Lipetsk
Portable Electrical Laboratory for Cable Damage Detection by Acoustic and Induction method Athlete KAI-1.501
Portable Electrical Laboratory for Cable Damage Detection by Acoustic and Induction method Athlete KAI-1.501
Appointment Athlete KAI-1.501 • Search for a live cable. • Detection of the passage of hidden communications (metal pipelines, cable lines). • Preliminary detection of the distance to the place of damage. • Search for places of cable damage in an acoustic way. • Search for places of cable damage by electromagnetic means. • The presence of a "Friend-Foe" mode.
Produced in: Kolomna, Moscow region
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
▪ Measurements without sampling in geometry 4π ▪ Intelligent detection unit in an airtight container ▪ The possibility of further detailed processing of the measured data using specialized software
Produced in: Belarus, Minsk
Laser dosimeter LD-07
Laser dosimeter LD-07
from 125 000 ₽
LD-07 laser dosimeters are designed to measure the energy exposure and irradiance of scattered or reflected laser radiation in automatic mode, as well as to analyze the measurement results in accordance with current sanitary norms and regulations No. 580491, IEC 825-1-93 in order to determine the danger of radiation to the human body.
Produced in: Moscow
2ZVE-400R Electromechanical vacuum shutter with gearbox
2ZVE-400R Electromechanical vacuum shutter with gearbox
The 2ZVE-400R vacuum shutter with electromechanical drive equipped with 400mm conditional passages is designed to overlap vacuum systems in the range of operating pressures from 1x10-6 to 1.07x105 Pa (0.75x10–8 to 800 mm Hg). The 2ZVE-400R shutter is pendulum-type. The 23VE-400R shutter is manufactured in climatic versions UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69. The working environment is air and non–aggressive gases. It is not intended for use in fire hazardous and explosive industries. The 23VE-400R shutter meets the requirements of technical specifications TU 3648-040-00218526-2003. According to the method of protecting a person from electric shock, it belongs to Class I electrical equipment according to GOST 12.2.007.0-75.
Produced in: Kazan
eLajt03-BT luxmeter-pulse meter-brightness meter for smartphone
eLajt03-BT luxmeter-pulse meter-brightness meter for smartphone
from 29 900 ₽
eLajt03-BT is a Bluetooth luxmeter for an Android smartphone. The version of the eLajt-03 photo head with a built-in Bluetooth adapter. Free Luxmeter app for Android on Google Play
Eco-E
Москва
Produced in: Moscow
X-ray Radiation Dosimeter clinical DRK-1E
X-ray Radiation Dosimeter clinical DRK-1E
Purpose: measurement of the product of the air kerma on the cross-sectional area of the X-ray beam at the output of the X-ray machine; determination of the power of the product of the air kerma on the cross-sectional area of the X-ray beam of light at the output of the X-ray machine; monitoring the stability of medical X-ray machines during their operation; verification of clinical dosimeters with pass-through ionization chambers (after certification as a working standard).
Doza
Zelenograd
Produced in: Moscow
Laboratory table low Mod. -900 SLL n "Laminate"
Laboratory table low Mod. -900 SLL n "Laminate"
from 17 660.87 ₽
The table is based on a reinforced O-shaped, collapsible metal frame made of shaped tube, rectangular and square cross-sections. The back wall is covered with a metal shield. The table is mounted on adjustable screw bearings, allowing the table to be installed horizontally, regarding the floor unevenness. Frame cover, high-quality powder-polymer paint, perfectly protects the base of the table from the effects of any aggressive liquids. The cover of the frame is easily cleaned with disinfectant solutions. The working surface of the Laminate table is a waterproof chipboard plate covered with chemically resistant and heat-resistant plastic.
Produced in: Saint Petersburg
EPR spectrometer CMS8400 NEO
EPR spectrometer CMS8400 NEO
The CMS8400 NEO is a compact electron paramagnetic resonance spectrometer designed for routine research in physics, chemistry, biology and related scientific fields for direct detection of free radicals and paramagnetic materials. The CMS8400 NEO can be used in both laboratory and industrial settings in the mode of on-line measurements, embedded in technological processes, thus providing control of parameters and reactions in the production process. Additional accessories and adapted software can make the spectrometer an analytical tool and allow to implement new complex applications in medicine, petrochemistry, brewing, sanitary and hygienic control, as well as in other industries.
Produced in: Belarus
Transportable hydrogen quantum clock PKCHV-M "SAPPHIRE"
Transportable hydrogen quantum clock PKCHV-M "SAPPHIRE"
Designed for: comparisons of time scales of geographically separated objects; time scale formation and storage; formation of highly stable signals with frequencies of 5 MHz, 10 MHz, 100 MHz; measurement of the difference in time scales of spatially spaced time standards located at a distance of up to 1000 km with an error of no more than 2 ns; measuring the frequency of reference signals of remote standards, as well as determining the parameters of instability of their frequencies and spectral characteristics of signals; time scale storage and a source of a reference highly stable signal on mobile and stationary objects.
VNIIFTRI
Mendeleevo
Produced in: Mendeleevo, Moscow region
Blocks of processing and transmission of information BOP-1sp
Blocks of processing and transmission of information BOP-1sp
Purpose: processing of information received from detection units (primary converters); data transmission to the information network; data transfer to a portable computer (remote control tuning PN-PC); storage of threshold settings and parameters of detection units (primary converters); power supply and diagnostics of detection units (primary converters); output of threshold exceeding signals to built-in sound and LED alarms and to remote alarm units (BAS/BAS-1c); output of discrete signals (dry contacts); archiving of data in non-volatile memory.
Doza
Zelenograd
Produced in: Moscow