Equipment

2245 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 389
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2245 products
Sandy bathhouse "PB MINI" I2T
Sandy bathhouse "PB MINI" I2T
from 45 576 ₽
Sandy bathhouse "PB MINI" I2T with digital control and a heating area of 200x400 mm. is designed for heat treatment of samples, evaporation and laboratory analysis. The product is equipped with a shutdown timer.
Produced in: Tula
Installation for determining the melt flow index of thermoplastics with auto-cutting PTR-LAB-11
Installation for determining the melt flow index of thermoplastics with auto-cutting PTR-LAB-11
Technical specifications: Melt flow rate for 10 min, g 0.1 - 99.9 The dimensions of the capillary opening, mm dia. 2,095 diam. 1,048 (optional) diam. 1,180 (optional) Set of loads, kg 0,325-5 10-21,6 (optional) Temperature range in the working chamber, °C +50...+450 Accuracy of temperature maintenance, °C: - in the range of 50...300 °C: ± 0.1 - in the range of 300...350 ° C: ± 0.2 - in the range of 350...450°C: ±0.3 The discreteness of setting the temperature of the chamber, ° C 1 Time to enter the operating mode, no more, min 40 Power supply, V/kW 220/0.8 Installation dimensions, WxDxH mm 513x445x590 (920 is the maximum height with a fully loaded polymer chamber and a full stack of loads with a handle for their installation) Installation weight, not more than 70 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Oxygen concentrator "Provita-140M"
Oxygen concentrator "Provita-140M"
Devices capable of generating oxygen have found application in various fields of medicine. The equipment is also used in training centers, educational institutions and oxygen rooms. Medical oxygen concentrators allow to accelerate the recovery of patients suffering from cardiovascular diseases, chronic respiratory diseases, as well as other pathologies that make it difficult to saturate the blood with oxygen. The concentrator is a mandatory equipment of the departments of anesthesiology and intensive care. Oxygen concentrators demonstrate high efficiency in restorative treatment. Unlike oxygen sources that use compressed gas, generators are safe and economical. Capacity: 140 l/min 8.4 m3/h 11.2 kg/h Oxygen purity: 95 % Oxygen pressure: 4-5 bar
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Mobile laboratory for 0.4-10 kV cable lines and cable lines made of cross-linked polyethylene (ETL-10/SNH)
Mobile laboratory for 0.4-10 kV cable lines and cable lines made of cross-linked polyethylene (ETL-10/SNH)
Laboratory equipment for 0.4-10 kV cable lines and cable lines made of cross-linked polyethylene (ETL-10/SNH) 1. Test facility • – Maximum rectified voltage up to 70 kV; • – Maximum AC voltage of the industrial frequency of 50 Hz to 50 kV. 2. SNCH test facility • – Sinusoidal 0-24 kV peak, symmetrical (error ± 1%); • – Rectangular 0-30 kV peak, symmetrical (error ± 1%); • – Constant 0-30 kV of both polarities (error ± 1%); • – Output current 0-30 mA resolution 1 ma (error ±1%); • – Resistance range 0.1 Mohm -15 Mohm; • – The frequency of the output signal is 0.01-1 Hz in increments of 0.01 Hz, automatic frequency selection. 3. Burning installation • – Maximum voltage up to 30 kV; • – Maximum current up to 80 A; • – Working hours are not limited; • – Switching of stages is carried out without breaking the arc at the time of switching; • – The ability to start working from any stage of burning (when working with low–voltage cables); - Built-in afterburning. 4. High voltage pulse generator • – Output voltage 0...12 kV / 0...24 kV; • – The pulse energy at each stage is 3000 J; • – Built-in IDM for collaboration with the reflectometer. 5. Reflectometer – Supports 3 methods of determining the location of damage: • – By pulse reflectometry; • – By the method of oscillatory discharge; • – Pulse-arc method. 6. High-voltage cable detector • – Determining the location and depth of the cable at a depth of up to 10 m; • – Tracing at a distance of up to 10 km; • – Search for live electrical cables; • – Search for places where the pipeline and cable intersect; • – Determining the places of damage to cable lines; • – Site surveys before excavation; • – Search for places of damage to the external insulation of the cable; • – GPS\GLONASS coordinates recording and mapping of found communications; • – Cable selection from the bundle; • – Search for the place of damage by acoustic method. 7. Autonomous gasoline generator • – Rated power 7.5 kVA.
Produced in: Kolomna, Moscow region
Muffle furnace LF-5/11-V2
Muffle furnace LF-5/11-V2
Design features: Special system of air intake and exhaust of combustion products with adjustable thrust; Programmable microprocessor temperature controller; Three programs of ten steps with the ability to set the temperature, heating speed and holding time for each step; Manual heating mode with timer with sound notification and auto-off; Durable ceramic muffle; Closed heaters on four sides of the chamber; Backlit graphic display; Conveniently located control panel; Automatic shutdown of heating when opening the door; Sound and light alarm; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1100 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x110x190 mm Overall dimensions, WxHxD, not more than mm 505x955x565 Rated supply voltage, 220 V Rated power, W 2800
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Laboratory drying cabinets SHS-40/3,5
Laboratory drying cabinets SHS-40/3,5
The electric drying cabinet SHS-40/3.5 is designed for drying, heating various materials in an air environment at a maximum temperature of 350 ° C. Technical specifications The electric cabinet operates at ambient temperature from 10 to 35 ° C and relative humidity up to 80% at 25 ° C. Operating temperature- 350 ⁰C Power consumption - 2500 W Dimensions of the working chamber WxDxH- 390x360x390 mm Dimensions WxDxH- 600x630x580 mm Weight - 67 kg
MIUS
Tula
Produced in: Tula
AVDM-100 High-vacuum Diffusion Unit
AVDM-100 High-vacuum Diffusion Unit
The AVDM-100 high-vacuum unit consists of a vacuum diffusion oil-vapor pump, a nitrogen trap, a vacuum gate, a frame or a plate. The principle of operation of the AVDM-100 unit is based on the pumping action of a vacuum diffusion steam oil pump. When the AVDM-100 unit is operating, liquid nitrogen is poured into the trap. Condensation of working fluid vapors occurs on the elements of the freezing device cooled with liquid nitrogen. The frame (plate) is designed for mounting the components of the unit. The ends of the wiring wires are connected to the connector fixed on the plate of the AVDM-100 unit.
Produced in: Kazan
Industrial Drying Cabinet SNOL (SHS) 500/3-I2 V
Industrial Drying Cabinet SNOL (SHS) 500/3-I2 V
from 1 122 264 ₽
The industrial drying cabinet is designed for drying, tempering, aging, thermal testing and other types of heat treatment of various materials in an air environment at temperatures up to 350 (optionally up to 500) ° C with forced air convection in stationary conditions.
Produced in: Tula
Analytical scales VL-84V
Analytical scales VL-84V
from 184 990 ₽
Technical characteristics: NIP, G82 Discreteness, g0,0001 Internal calibration The smallest weighing limit, g0.01 The diameter of the scale bowl, mm91 The price of the calibration division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 82g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, seconds, no more - fast mode - 2; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x213x338 Weight of the scales, kg, not more than 6.2 The adjustment weight is built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
LB41 Laboratory bath
LB41 Laboratory bath
It is intended for thermostating samples in glasses, flasks and other laboratory utensils in cases when high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. Three workstations with a diameter of 110 mm with five steel O-rings. Stamped steel bath with a volume of 8 liters and a depth of 60 mm. Bath volume 8 l Overall dimensions 385x370x265 mm The open part of the bath is 325x290 mm Bath depth 60 mm Weight 10 kg Power consumption 2.5 kW
Produced in: Tomsk
Monoblock liquid cooling unit MCHV-15
Monoblock liquid cooling unit MCHV-15
from 288 495 ₽
Designation MCHV-15 Cooling capacity at Two.water= +15C, Tcond=+45C, Current.cp.=+30C, kW 15 Required pump capacity, m3/h 3.3 Pressure loss in the heat exchanger, kRa 65
Produced in: Tula