Equipment

2278 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 393
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 89
    Additional
    Loading...
View:
2278 products
Vibration automatic monitoring and tracking equipment "Basis-001"
Vibration automatic monitoring and tracking equipment "Basis-001"
The equipment "Basis-001" is designed to measure vibration parameters, set and automatically maintain vibration parameters, control the vibration spectrum and determine resonant frequencies as part of vibration electrodynamic test units of the VEDS series (VEDS-100M; 200M; 400M; 1500M) and similar
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
High-precision cmart surface probe L =500 mm SZPWT.500P with built-in flash memory
High-precision cmart surface probe L =500 mm SZPWT.500P with built-in flash memory
from 14 580 ₽
High-precision cmart surface probe L =500 mm SZPWT.500P with built-in flash memory is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPVT smart probe.500P Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPVT smart probe.500P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Wireless set for measuring the temperature of ferrous metal melts with logging function
Wireless set for measuring the temperature of ferrous metal melts with logging function
from 95 600 ₽
The kit is designed to measure the temperature of ferrous metal melts. It consists of a digital contact thermometer TK-5.27 complete with a submersible high-temperature probe, designed to measure the temperature of metal melts in the range of +600 ° C ... +1800 ° C. The digital contact thermometer TK-5.27 is equipped with the function of recording measurements in the device's memory, followed by transferring data to a computer and providing reports in the form of tables and graphs. To measure the temperatures of metal melts, disposable thermocouples of the PPR (B) type with a protective tube length of no more than 900 mm are used. The kit is adapted to the replacement blocks of EVRAZTEMP ET-V-09-00. •
Produced in: Moscow
High-frequency signal generator G4-230
High-frequency signal generator G4-230
The generator is capable of operating both autonomously and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range from 5 to 17.85 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main output is from minus 110 to 13 dBm The basic error of setting the reference power level is ± 1.0 dB Instability of the output signal power level for any 15-minute time interval of no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal: low frequency from 1 Hz to 20 kHz RFM from 10 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value): low frequency from 1 Hz to 100 kHz RFM from 50 to 10000 kHz - the main error of the frequency deviation setting is ± (3 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the main error in setting the amplitude modulation coefficient: Internal ± (0.15M + 0.2)% External ± (0.20M + 0.5)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 15 kg
Produced in: Moscow
Verification module PM-9
Verification module PM-9
The composition of the PM-9 calibration module: Universal voltmeter calibrator H4-12 (2 pcs.); Variable voltage calibrator H5-5A; A measure of the stress ratio H4-8; AC voltage voltmeter VK3-78A; Generator-calibrator of harmonic signals SK6-122; The meter-calibrator of the harmonic coefficient SK6-20A; AC power source B2-7 (2 pcs.); The measure of DC electrical resistance is multi-valued MS3070-2; The measure of DC electrical resistance is multi-valued MS3055; Decadal high-resistance resistance magazine M-109R; Single-digit electrical resistance measures MS3080 (0.001; 0.01; 0.1 ohms); Electrical resistance measures unambiguous MS3050M (1, 10, 100, 1000, 10000, 100000 Om); The measure of electrical resistance is unambiguous P4013; The measure of electrical resistance is unambiguous P4023; The measure of electrical resistance is unambiguous P4033; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical quantities: Constant electrical voltage DC from 1 MV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 10 mV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 10 Hz ... 2000 MHz from 10 mV to 100 V Harmonic coefficient in the frequency range of 10 Hz ... 200 kHz from 0.001 to 100 % Ranges of reproduction of electrical quantities: Constant electrical voltage DC from 1 nV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 3 MV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 1 MHz ... 2000 MHz from 3 MV to 3 V DC electric current from 1 µA to 20 A The power of alternating electric current in the frequency range from 0.1 Hz to 10 kHz from 1 µA to 20 A Electrical resistance from 0.001 ohms to 11 ohms Harmonic coefficient in the frequency range from 10 Hz to 200 kHz from 0.001 to 100 % Measurement errors of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage, in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 1.2) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.2 ... 6.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.0008 ... 2.0) % Errors in the reproduction of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 4.0) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.6 ... 10.0) % DC power ± (0.0033 ... 0.5) % The power of alternating electric current in the frequency range from 10 Hz to 10 kHz ± (0.055 ... 1.0) % Electrical resistance ± (0.001 ... 1.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.006 ... 2.0) % General technical characteristics: The area occupied by the module is 6-12 m2 Weight, not more than 430 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, no more than 2000 VA
Produced in: Moscow
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
▪ Measurements without sampling in geometry 4π ▪ Intelligent detection unit in an airtight container ▪ The possibility of further detailed processing of the measured data using specialized software
Produced in: Belarus, Minsk
Smart air probe L=150 mm SSV.150P with built-in flash memory
Smart air probe L=150 mm SSV.150P with built-in flash memory
from 12 351 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object The smart air probe L=150 mm SSV.150P with built-in flash memory is designed to measure the temperature of various media by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor. Android program is installed. Operating conditions of the SZV.150P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSV.150P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
General purpose exhaust cabinet LAB-PRO SHV 90.74.230 SS
General purpose exhaust cabinet LAB-PRO SHV 90.74.230 SS
BASIC EQUIPMENT Working box guide racks – aluminum profile painted with powder paint (RAL 7035/RAL 5023)in the right rack there are a light switch and 2 splash-proof sockets with a 3.2kW cover (IP54) the front anti–spill side is acid-resistant polished stainless steel AISI 304 side panels – tempered glass 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – metal painted with powder paint (RAL 5023) with the texture of shagreen leather on the top panel: LED lamp dust- and moisture-proof (10W IP65) switching box with automatic emergency power off 16A flange d=250mm (the distance from the back panel to the center of the flange is 170mm) easily removable exhaust canopies 3 levels of exhaust (lower, side and front) counterweights are placed in the front pillars-pylons and are easily serviced by the rear and upper panels – polypropylene The frame base is a collapsible frame made of a rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel is a metal box painted with powder paint (RAL 5023) with the texture of shagreen leather: adjustable supports.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Non-pressure hybrid flow meter-counter Volga Triton
Non-pressure hybrid flow meter-counter Volga Triton
from 300 000 ₽
The Volga Triton pressure-free hybrid flow meter is designed to measure the volumetric flow of liquid in water ducts with a pressure-free and combined pressure-free flow mode. The submerged primary speed converter operates on the basis of the Doppler effect, emitting an ultrasonic signal towards the flow and receiving an echo reflected from particles in the flow with a frequency different from the frequency of the emitted signal. This frequency shift is called the "Doppler Shift" and it is proportional to the flow rate. A non-contact ultrasonic primary converter VBN-DG-01 or any other third-party liquid level converter with a unified current output of 4-20 mA can be used as a depth meter: radar, hydrostatic or ultrasonic. The volumetric flow rate is determined both by the "area-speed" method and by MI2220-2013, depending on hydraulic conditions. In non-contact (radar) mode, the Volga Triton flowmeter is designed to measure the volumetric flow rate of a liquid in a non-pressurized flow mode. The flow meter can be used as part of waste water metering units in non-pressure (gravity) sewage systems, open irrigation and reclamation channels, open or underground derivational non-pressure water pipelines of hydropower facilities, diverting supply and recirculation water pipelines of thermal power and other hydraulic structures with a non-pressure flow regime. The measurement technology is based on a non-contact radar method for measuring surface flow velocity and a non-contact ultrasonic/radar method for measuring water level. As a water level meter, both the proprietary ultrasonic level sensor BP-G-01 and third-party sensors connected via unified digital or analog interfaces, for example, VEGAPLUS, can be used. The pressure-free hybrid flow meter "Volga Triton" became the winner of the International Environmental Award EWA Award 2021 in the nomination Best technology. Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters VBN-DS-01 Primary speed converter for medium and large water pipelines VBN-DS-02 Combined primary speed and depth converter for medium and small aqueducts VBN-DS-03 is a combined low-profile primary speed and depth converter for small aqueducts. VBN-DG-01 - contactless ultrasonic primary transducer - depth meter Pipe sizes Du, mm: 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 6000 mm
Produced in: Moscow
Voltmeter demonstration universal VDU-1
Voltmeter demonstration universal VDU-1
Designed to measure electrical quantities (DC voltage and strength, AC voltage and strength, DC electrical resistance) during demonstration work in physics. The device performs the function of a demonstration multimeter. Technical specifications: Measurement of DC voltage from 0 to 100 V measurement error, not more than 1.0 % Measurement of AC voltage from 0 to 60 V measurement error, not more than 1.0% measurement of DC power from 0.01 to 200 measurement error, not more than 1.0 % Measurement of AC power from 0.01 to 200 mA measurement error, not more than 1.0 % Measurement of DC resistance from 1 ohm to 2 mOhm measurement error, no more than 1.0% power supply from the USB port of the computer power consumption, no more than 0.6 V × A weight, no more than 0.3 kg overall dimensions 172x25x77 mm
MNIPI
Minsk
Produced in: Belarus, Minsk