Equipment

2226 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 387
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 99
    Additional
    Loading...
View:
2226 products
Mass spectrometer for the analysis of solid-phase samples "Lumas SOLID"
Mass spectrometer for the analysis of solid-phase samples "Lumas SOLID"
1 supp.
Technical specifications: Method of ionization Plasma pulsed glow discharge Discharge gas Argon, consumption less than 1 l/hour Time-of-flight Mass Analyzer with mesh-free ion mirror Resolution 4000 The number of simultaneously defined components is unlimited Mass range 1-1000 m/z Detection limits 1-100 ppb Layer-by-layer resolution Up to 5 nm Depth of analysis Up to 30 microns The time for one analysis of a solid sample is 30 minutes (with the option of a revolver system – 3-5 minutes) Vacuum system 1 Booster pump and 2 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Scanning probe microscope SMM-2000
Scanning probe microscope SMM-2000
Viewing and measuring grains and defects in the structure of materials, resolution to atoms (Nobel Prize in 1986), replacement of metal-graphic and electron microscopes Increase: from x2 thousand to x10 million. Measuring range: 0.2 nm to 30 microns All basic (STM, contact and vibro-AFM) modes, and more than 25 extras.modes
Produced in: Moscow, Zelenograd
Capillary electrophoresis systems "KAPEL®-104T"
Capillary electrophoresis systems "KAPEL®-104T"
1 supp.
Technical specifications: The working wavelength of detection, nm 254 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 150 Overall dimensions (LXC), mm, no more 420x460x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Acousto-optic video spectrometer
Acousto-optic video spectrometer
At the Scientific Research Center of the Russian Academy of Sciences, the technology of acousto-optic filtration of optical radiation is used to create a wide class of optical devices that are successfully used, for example, in biomedicine to diagnose various diseases (including oncology), in agriculture to diagnose the condition of plants, during non-destructive testing of complex technical objects and in solving other tasks. Acousto-optics has a number of important advantages over other technologies for obtaining spectral information: - the ability to create imaging devices without spatial scanning, since the acousto-optic filter is a software-controlled tunable light filter; - the compact modular design allows the acousto-optic filter to be integrated into the optical circuit of most imaging devices, which expands their analytical capabilities; - spectrum scanning is carried out by means of an electrical signal, without mechanical scanning; - fast arbitrary spectral addressing causes high shooting speed and the absence of redundant information; - software management. The key element of the presented device – an acousto–optic filter - is being developed at the Scientific Research Center of the UP RAS on the basis of original calculation methods. The manufacture of acousto-optic filters, optical and mechanical components, as well as the assembly, tuning, and calibration of such devices is also carried out at the Scientific Research Center of the UP RAS.
STC UP RAS
Москва
Produced in: Moscow
Liquid analyzer "FLUORAT®-02-5M"
Liquid analyzer "FLUORAT®-02-5M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, no more 0,005 Measurement range of the mass concentration of the control substance (phenol) in water, mg/dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ± 2 Warm-up time, min, no more than 30 Continuous operation time, h, at least 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, no more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, In × A, no more than 36 Time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Model 130 Profilometer
Model 130 Profilometer
Measurement of roughness parameters Ra; Rz; Rmax; Rp; Rv; Rq; Sm; S; la; lq; tp; Lo; D; da; dq, etc., viewing the profilogram and measuring the size of inhomogeneities Tracing length: 0.5mm – 40 mm Measurement range according to Ra: 0.012 – 50mkm Degree of accuracy 1 (error 2%) Work inside the vestibule > 3mm
Produced in: Moscow, Zelenograd
Installation for obtaining analytical quality water UPVA-5-1
Installation for obtaining analytical quality water UPVA-5-1
from 312 000 ₽
water type I: 5.0, water type II: 5.0 Purpose obtaining super pure type 1 water according to GOST 52501-2005 "Water for laboratory analysis" FS.2.2.0019.18 "Water for injection" Heating elements Heating element 3.5 kW 220V (stainless steel) – 1 pc. The quality of the produced water according to the requirements for type I and II water according to GOST 52501-2005 "Water for laboratory analysis" and the articles of the FS.2.2.0019.18 "Water for injection" Type of current, frequency, voltage variable single-phase, 50 Hz, 220 V Power consumption, kW 3,6 Overall dimensions (L×W×C), mm 670×470×490 Weight, kg 35.0
Livam
Belgorod
Produced in: Belgorod
Orbital Shaker LOIP LS-221
Orbital Shaker LOIP LS-221
Technical specifications: Type of motion orbital Platform rotation speed, min-1 20-500 The amplitude of rotation of the platform, mm 10 Maximum load on the platform, kg 8 Timer (time is displayed in h, min, s) up to 8 hours Power consumption, W 80 Platform size, mm 300x220 Overall dimensions, mm 355x320x200 Weight, kg 18
LOIP
Saint Petersburg
Produced in: Saint Petersburg
pH meter MARK® 903
pH meter MARK® 903
Measurement of the activity of hydrogen ions (pH, pH25), ORP, EMF and temperature of aqueous media. Operational control of parameters of water-chemical regimes at thermal and nuclear power facilities, in accordance with CO 153-34.37.303. Convenience and accuracy of measurement | Automatic temperature compensation. Automatic recognition of buffer solutions. Measurement modes | pH or pH25 and temperature. EMF and temperature. pH measurement in flow and immersion modes | The flow-filling module MPN 901/903 is included. Self-diagnosis | Non-volatile electronic notebook | The ability to record up to 500 measurement groups in User-named folders. USB port, software included | The ability to create and manage a data archive on a PC. Graphic indicator with backlight | Indication of readings in a user-friendly format. Ease of settings. IP65 | Compact sealed device is reliably protected from dust and moisture. Low power consumption | Up to 600 hours of continuous operation from a set of AA elements.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod