PYROLYZER
PYROLYZER
The pyrolytic gas chromatography method is widely used in the study of polymer materials, plastics, rubbers, rubbers, paints and other high-molecular compounds of natural and artificial origin. The method is based on thermal decomposition of sample samples in an inert medium (without oxygen access), followed by chromatographic separation and analysis of the formed volatile compounds. Thus, the resulting pyrogram allows us to judge the composition of the original sample. Pyrolysis is also used in geochemical studies. Technical specifications The volume of the capsule is 56 ml. Pyrolysis temperature — from 200 to 1000 °C. The error of maintaining the temperature is not more than 1.0 ° C. The heating time of the sample to the pyrolysis temperature is no more than 2 seconds. The cooling time of the capsule when moving from the hot zone to the cold zone after pyrolysis is no more than 10 seconds. The time of continuous operation in the pyrolysis mode is no more than 60 seconds. Electric power supply from the AC network with voltage (220index) V, frequency (50 ± 1) Hz. Power consumption — no more than 100 VA. Overall dimensions of the control unit (width ×depth×height) — 210×190×100 mm. Overall dimensions of the input node (width× depth×height) — 90×135×160 mm. The weight of the control unit is not more than 2.5 kg. The weight of the input node is not more than 0.9 kg.
Produced in: Yoshkar-Ola, Mari El
THE DEVICE FOR ACHIEVING BALANCE
THE DEVICE FOR ACHIEVING BALANCE
When analyzing gases dissolved in transformer oil using the ARP method (equilibrium vapor analysis), mixing of the contents of the syringe with oil is used to accelerate the extraction of gases (to achieve an equilibrium distribution of gases dissolved in oil between the liquid and gas phases). For this purpose, as well as automation of the mixing process, a special autonomous device for achieving equilibrium is produced. technical specifications The rotation speed of the syringe drum is 30 rpm./min. The rotation time (determined by the internal timer, after pressing the "Start" button) is 10 minutes. The number of syringes placed is 4. The volume of syringes is 20 or 50 ml. Power consumption, no more than — 14 VA. Overall dimensions, no more than 210×280×270 mm. Weight, not more than — 5 kg.
Produced in: Yoshkar-Ola, Mari El
GAS FLOW REGULATOR
GAS FLOW REGULATOR
The flow regulator consists of the following parts: Body. It includes a connector for connection to the control controller and fittings for connecting the input and output gas lines. Calorimetric converter. Due to the heating of the gas along the flow section, the temperature difference is determined. The actuator (solenoid valve). The control board. A system of elements responsible for converting the signals that the user submits. TECHNICAL CHARACTERISTICS OF RD The gas pressure at the inlet is (0.4 + 0.04) MPa. Ranges of working gas flow rates — from 5 to 800 ml/min. The ability to specify the type of gas (nitrogen, helium, hydrogen, argon, air). Pressure ranges — from 0.001 to 0.40 MPa with a discreteness of 0.0001 MPa. The deviation of the carrier gas flow rate from the average value is + 1.5% in the flow range from 50 to 100 ml/min and + 0.5 ml/min in the flow range from 3 to 50 ml/min. Relative deviation of the average steady-state gas flow rate from the set value in the range from 3 to 100 ml/min: + 2.5%, but not less than 0.5 ml/min; from 100 to 200 ml/min.: + 5%; from 200 to 800 ml/min.: + 10%. The gas pressure at the inlet is (0.4 + 0.04) MPa. The deviation of the regulated output pressure of the regulator from the set value is not more than 1%.
Produced in: Yoshkar-Ola, Mari El
Portable microscope SIAMS MAP-5
Portable microscope SIAMS MAP-5
● Magnification range: 50 - 800x ● Interchangeable lenses planachromat 5x/0.12, 10x/0.25, 20x/0.40, 40x/0.60 (on request), 50x/0.70, 80x/0.80 with extended working range ● Eyepiece 10x/18mm ● Illuminator: LED illuminator with stabilized source and built-in battery. Lighting adjustment with linear intensity change. The charger is included. ● Microscope tripod with height adjustment with a stroke of 35 mm. The ability to tilt the tripod at an angle of ± 20 degrees forward and backward to take pictures of a curved surface without moving the microscope from the mounting point ● Moving the lens 30x30 mm along the X-Y axes ● Coarse and fine focusing handles ● Strong magnetic fastening on 3 points using hinged supports for mounting on curved convex and concave steel surfaces, including pipe bends with a diameter of 60 mm ● Anti-slip nozzles ● Metal mounting for non-magnetic surfaces with ratchet mechanism ● The base for fixing the microscope in stationary operation ● Bayonet mount for camera ● C-mount mount for video camera ● Transport plug for video output ● A case for carrying a microscope with a camera.
SIAMS
Екатеринбург
Produced in: Ekaterinburg
Pilot fermenter 15-50 L for pharmaceuticals
Pilot fermenter 15-50 L for pharmaceuticals
Biotechno pilot fermenters have a fully aseptic design and are easily validated. The universal C-Bio control system, unified for fermenters of any volume, greatly simplifies the scaling process and allows you to transfer fermentation data to larger fermenters. The total volume is 15-50 liters Working volume 10.5-35.0 l Material of manufacture: 316L stainless steel (for parts in contact with the product) Stainless steel grade 304L (for parts not in contact with the product) Design pressure 3.0 kg/cm3 (capacity) 4.0 kg/cm3 (jacket) Design temperature 143°C (capacity) 151°C (shirt) Surface treatment Internal polishing 0.4 µm + electropolishing External polishing 1.2 µm Ports on capacity Upper Port for diaphragm pressure gauge Port for diaphragm pressure transmitter Bursting membrane Exhaust gas outlet and condenser Inoculation Viewing window Foam sensor port Nozzle for CIP Spare port Upper side walls Air supply Viewing window Culture liquid supply x 3 Ring Bubbler Spare port Lower side walls Port for PT100 temperature resistor sensor Port for pH sensor Port for dissolved oxygen sensor Spare port Sampling port Shirt Steam supply / outlet of the cooled water Steam output / Cold water supply (including safety valve and pressure gauge) Low drain valve 2. Mixing mechanism Top drive with single mechanical seal 0.25 kW DC motor Speed 30-600 rpm (inverter control) Val – F20 Adjustable three-level paddle stirrers 3 welded partitions 3. Aeration mechanism Automatic air supply 2 VVM 5" high-efficiency 0.2 µm filter and 316L stainless steel filter housing Automatic Air flow meter 4. Pressure mechanism The bursting disc Pressure gauge Positioner Pressure sensor Pressure control valve 5. pH/DO control mechanism pH sensor pH Sensor Holder Cable for pH sensor DO sensor DO Sensor Holder Cable for the DO sensor Peristaltic pump (fixed 20 rpm) x 2 Bottle 1 l x 2 6. Defoaming mechanism Defoaming sensor Cable for defoaming sensor Peristaltic pump (fixed 20 rpm) x 1 1 L x 1 bottle 7. Temperature control mechanism Temperature sensor (PT 100) Heat exchanger Pump 8. Strapping and frame Support Corners and channels – STS304 Manufactured strapping Air supply Supply of process steam Supply of pure steam Cooling water supply Return of cooling water Drain of waste water Drain of waste liquids Exhaust gas output Instrumentation Diaphragm valve Direct flow valve Steam trap Membrane pressure gauge Ball valve and pneumatic angle valve Check valve Safety valve Crankshaft, tee Welding of pipes Orbital welding (line in contact with the product) Manual welding (common line)
Produced in: Moscow
Mains current indicator autonomous “STORK” EI3008
Mains current indicator autonomous “STORK” EI3008
Technical specifications The indicator provides the ability to measure current without breaking circuits at a height of up to 7.5 m from ground level. Power supply: two AAA elements of 1.5 V. Operating conditions: temperature from -10°C to +40°C, relative humidity 80% at +25 °C. Overall dimensions in the working position 6600x70x80 mm Overall dimensions in the stowed position (cover) 1700x100x70mm. Weight 2.5 g. As a measuring device, a digital multimeter with a memory function, semi-automatic selection of measurement limits is used. Measurement of alternating current up to 500 A with a measurement accuracy of 3%. Measurement of AC and DC voltage up to 600 V with a measurement accuracy of 2%; resistance measurement – up to 2.0 M ohms. Ringing of electrical circuits. Structurally, the indicator consists of four fiberglass rods articulated with each other using connectors. On the upper rod there is a detachable magnetic circuit covering the wire in which the current must be measured. On the lower rod there is a measuring device that records the current values. They are not subject to mandatory certification (they are not included in the “Nomenclature of products and services (works) for which mandatory certification is provided by legislative acts of the Russian Federation”. It was put into effect from 01.12.2002 by the resolution of the State Standard of the Russian Federation No. 64 dated 30.07.2002.)
Produced in: Krasnodar
Nitrogen traps
Nitrogen traps
Nitrogen traps are designed for use in various vacuum systems in order to prevent the ingress of vapor gases and various organic compounds from high-vacuum and pre-vacuum pumps into the vacuum chamber (system) following in the reverse flow, as well as to protect vacuum units from organic substances present in the vacuum volume.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Non-standard vacuum testing equipment
Non-standard vacuum testing equipment
For scientific and industrial applications.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Liquid thermostat ZM1004
Liquid thermostat ZM1004
Technical specifications the maximum temperature value in the thermostat is 95 °C. the range of water heating is from the current temperature to 95 ° C. The accuracy of automatic temperature maintenance is 0.5 °C. power supply parameters at which technical characteristics are normalized: type of current – alternating single-phase; voltage , V — 220±22; AC frequency , Hz — 50 ±1; the power consumption when entering the mode should be no more than, kVA — 4; the power consumption while maintaining the temperature should be no more than, kVA - 2. Operating conditions: ambient temperature – from plus 10 to plus 35 ° C.; relative humidity, from 65 to 80%. the electrical insulation resistance between the electrical circuits and the housing at ambient temperature (20 ± 5) ° C and relative humidity (80 ± 3)% is not less than 20 mOhm. electrical insulation between the electrical circuits and the housing under the conditions of clause 2.8. must withstand an AC voltage of 1.5 kV sinusoidal frequency of 50 Hz. overall dimensions not more than, mm: 520x420x480. tank volume – 40 liters. the average service life is at least 10 years. the weight of the thermostat is not more than 26 kg.
Produced in: Krasnodar
Helium mass-spectrometric leak detector TI1-50M “HeliTest” from NPO “Helikon”
Helium mass-spectrometric leak detector TI1-50M “HeliTest” from NPO “Helikon”
The helium leak detector TI1-50M is a universal highly sensitive device designed to test the tightness of various systems and objects that allow pumping out the internal cavity, as well as those filled with helium or a mixture containing helium, and detect (localize) places of leakage (leaks). Specifications: Measuring range at the leak detector inlet, Pa•m3/s from 5•10-13 to 1•10-5; Range of indications when working by probe method, Pa•m3/s from 1•10-9 to 1•10-5; Time to enter the readiness mode for measurements, no more than, min 5; AC supply voltage, V, Hz 220±10%, 50±1; Power consumption, VA 1200; Overall dimensions (WxHxD), no more than, mm 480x470x390; Weight, no more than, kg 40; Average time to metrological failure, h 15000;
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Spreading cone KR-1
Spreading cone KR-1
Device indicators: — minimum diameter of a concentric circle, mm — ( 72 ); — maximum diameter of a concentric circle, mm — ( 250 ); — the distance between the circles of the cone, mm — ( 5 ); — height of the sampling cone, mm — ( 60 ); — upper inner diameter of the sampling cone, mm — ( 37 ); — lower inner diameter of the sampling cone, mm — ( 70 ); — measurement error, mm — ( +2.5 ); — overall dimensions of the cone, mm — ( 280x120 ); — the mass of the cone, kg — ( 4 ).
Produced in: Krasnodar
Halogen leak detector "GTI-8"
Halogen leak detector "GTI-8"
It is designed to search for leaks of freons and other halogen-containing gases, for example, gas, in working equipment, and when testing systems, including cable ones, for tightness. The GTI-8 halogen leak detector also allows detecting an increase in the concentration of such gases in the room or near the controlled object. Technical characteristics of the leak detector "GTI-8" Parameter Sensitivity of the leak detector GTI-8, m3 Pa/sec., not less 1.0 - 5.3/10e-7 Time constant, sec., no more 3 Compensation of the initial sensor current Availability Automatic background signal compensation Availability Adjustable trigger threshold Availability Food ~220V, 50Hz (14.8V for GTI-8B) For modification of GTI-8B, continuous operation time, hour, at least 8 Operating mode setting time, min, no more 5
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg