Equipment

2245 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 389
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2245 products
VT10 Liquid thermostat
VT10 Liquid thermostat
It is designed to maintain a set temperature of a liquid coolant circulating both in an internal bath and in external closed-type consumers. Feed pump for external closed-type thermostating systems. All-metal stamped tub with a volume of 10 liters and a depth of 200 mm. The stability and uniformity of the temperature in the inner bath is not worse than ± 0.1 ° C. The operating temperature range is +20...+200 °C. The volume of the bath is 10 liters Overall dimensions 400x275x480 mm The open part of the bath is 120x200 mm Bath depth 200 mm Weight 14 kg Power consumption 2.2 kW
Produced in: Tomsk
LB22 Laboratory bath
LB22 Laboratory bath
It is designed for thermostating samples in glasses, flasks and other laboratory utensils in cases when high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. Two workstations with a diameter of 110 mm with five steel O-rings. Stamped steel tub with a volume of 5 liters and a depth of 110 mm. The volume of the bath is 5 liters Overall dimensions 385x205x310 mm The open part of the bath is 295x145 mm Bath depth 110 mm Weight 7 kg Power consumption 2.5 kW
Produced in: Tomsk
Bath for the determination of paraffins BF
Bath for the determination of paraffins BF
The volume of the bath is 5 liters Overall dimensions 420x280x500 mm The open part of the bath is 230x235 mm Weight 7.5 kg
Produced in: Tomsk
Power supply BP-1
Power supply BP-1
A power supply for red laser modules.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Technical laboratory scales VLTE-1100P-V
Technical laboratory scales VLTE-1100P-V
from 37 490 ₽
Technical characteristics: NIP, G1100 Discreteness, g0.05/(0.02)* Internal calibration The size of the scale bowl / platform, mm175 x 145 The smallest weighing limit, g2.5 Limits of permissible error during primary verification, mgot 2.5g to 500g incl. ±50; sv. 500g to 1100g incl. ±100 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Tracer detector for diagnostics of non-metallic and metal pipelines Athlete TEK-120TUZ
Tracer detector for diagnostics of non-metallic and metal pipelines Athlete TEK-120TUZ
from 329 400 ₽
A frost-resistant kit with a powerful generator that solves problems on metal and non-metallic pipelines designed for: • – search for underground utilities (power and signal cable lines, reinforced fiber-optic lines, pipelines made of electrically conductive materials), as well as determining the depth of their occurrence and places of damage. • – determination of the location of power cable lines by induction and acoustic methods. • – high-range tracing and highly efficient search for cable damage sites. • – tracing of non-metallic and metallic pipelines by acoustic method and search for leaks from pipelines.
Produced in: Kolomna, Moscow region
FREQUENCY UNLOADING CABINET "PARMA SHE ACR"
FREQUENCY UNLOADING CABINET "PARMA SHE ACR"
The following options can be implemented on request: •additional time relays - allow you to time load control commands within one queue •output of ACR/CHAPV signals on one bus: the appearance of a signal - ACR, the disappearance of a signal - CHAPV •installation of a panel measuring device on the cabinet door •manufacture of cabinets of other dimensions, design and number of unloading queues •manufacture of outdoor cabinets
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Laboratory drying cabinet SNOL-F-67/350-I2
Laboratory drying cabinet SNOL-F-67/350-I2
from 101 925 ₽
The laboratory drying cabinet SNOL-F-67 is designed for thermal testing, aging, as well as drying, tempering and other types of heat treatment of various materials in an air environment at temperatures up to 350 (optionally up to 500) ° C with natural or forced air convection in stationary conditions.
Produced in: Tula
Universal voltmeter V7-81
Universal voltmeter V7-81
The voltmeter is capable of operating both independently and as part of automated measuring systems with RS-232 type interfaces. Technical specifications Ranges of measurement of electrical quantities: - constant electrical voltage from 10 MV to 1000 V - SCR of alternating electric voltage in the frequency range from 10 Hz to 10 MHz (AC) from 1 mV to 750 V - DC current from 0.1 µA to 20 A - SCR of alternating electric current in the frequency range from 10 Hz to 5 kHz from 10 µA to 20 A - electrical resistance from 10 mOhm to 1 GOm - frequency of the measured alternating electric voltage from 10 Hz to 1 MHz Measurement errors of electrical quantities: - constant electrical voltage ± (0.0028 - 20)% - SCR of alternating electric voltage in the frequency range from 10 Hz to 10 MHz (AC) ± (0.09 - 15)% - DC power ± (0.012 - 20)% - SCR of alternating electric current in the frequency range from 10 Hz to 5 kHz ± (0.11 - 2.35) % - electrical resistance ± (0.007 - 5.5)% - frequency of the measured alternating electric voltage ± (0.1 -10.1)% General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 20 VA Overall dimensions, mm 291x110x308 Weight, not more than 4.5 kg
Produced in: Moscow
Blue DPSS Laser 420 nm KLM-420-x
Blue DPSS Laser 420 nm KLM-420-x
DPSS lasers of the KLM-420/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes. Technical specifications Radiation output power: up to 10W Radiation wavelength: 420 nm Output beam diameter: 1.5mm Divergence of the radiation beam: 1.3 mrad Instability of radiation power: 5% Type of modulation: TTL or analog Time to enter the mode: 15min Spectral line width: 0.1nm
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
OPTICAL REPEATER PARMA OT-8
OPTICAL REPEATER PARMA OT-8
Purpose and functions: · Transmission of accurate time signals via the IRIG-B protocol to remote subscribers via optical communication channels up to 1 km · Retransmission of signals to several channels, thereby ensuring the connection of one to eight devices to one time server
PARMA
Saint Petersburg
Produced in: Saint Petersburg