Smart air probe L=150 mm SSV.150P with built-in flash memory
Smart air probe L=150 mm SSV.150P with built-in flash memory
from 10 740 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object The smart air probe L=150 mm SSV.150P with built-in flash memory is designed to measure the temperature of various media by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor. Android program is installed. Operating conditions of the SZV.150P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSV.150P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
High-precision smart surface probe L =300 mm SZPWT.300P with built-in flash memory
High-precision smart surface probe L =300 mm SZPWT.300P with built-in flash memory
from 13 920 ₽
High-precision smart surface probe L =300 mm SZPWT. 300P with built-in flash memory is designed to measure the temperature of various materials by directly contacting the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPVT smart probe.300P Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPVT smart probe.300P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect external power. Possibility of calibration.
Produced in: Kolomna, Moscow region
Central Heating Unit Kit
Central Heating Unit Kit
The kit is designed to control the temperature and pressure of the coolant and archive the measured results for further documentation and analysis. The main purpose of the kit is to control the coolant parameter, monitor the pressure and pressure drop between the supply and return pipelines, and fix hydraulic shocks. Features of the CTP kit The CTP kit allows you to control the parameters of the coolant supply, temperature and pressure. The kit consists of a four-channel meter-recorder, which allows you to store 15,000 values in memory for each channel with an interval of 5 seconds. up to several hours, which allows you to take measurements and store data for up to 1 year. The CTP kit allows you to monitor temperature and pressure around the clock throughout the year, and if necessary, for a longer period. With the help of the CTP kit, we see all the dynamics of the development of the situation of changes in temperature and pressure of the coolant, including weekends (crimping, stopping, starting the heating network, operating modes). The kit allows you to increase the responsibility of personnel for compliance with technological regimes. There is a real-time indication that allows personnel to monitor the parameters of the supplied coolant. A set of TTP is usually installed at the border of responsibility, i.e. at the point where, according to the contract, the supplier is obliged to supply a certain amount of coolant with a specific temperature and pressure parameters.
Produced in: Kolomna, Moscow region
Dosimeter-radiometer ISS-05 "Terra" Bluetooth
Dosimeter-radiometer ISS-05 "Terra" Bluetooth
Modification of the ISS-05 "TERRA" dosimeter-radiometer with a Bluetooth radio channel module. A small-sized device for monitoring radiation conditions with the ability to save and transfer measurement results to a PC. Purpose: measurement of the ambient dose equivalent of N*(10) gamma radiation; measurement of ambient dose equivalent of H*(10) gamma radiation; measurement of beta particle flux density;
Doza
Zelenograd
Produced in: Moscow
Voltmeter V7-77
Voltmeter V7-77
Technical specifications: DC voltage , Measuring range, 10 mv-1000V Measurement error, ± (0.05% +4 E.M.R.) AC voltage , Measuring range, 1 mV - 750 V Measurement error, ± (0.5% +4 E.M.R.) Frequency range, 20 Hz- 100 kHz Direct current , Measuring range, 0.1 µA - 10 A Measurement error, ± ( 0.25% +4 E.M.R.)
MNIPI
Minsk
Produced in: Belarus, Minsk
Measuring recorder IS-203.4
Measuring recorder IS-203.4
from 36 000 ₽
The IS-203.4 meter-recorder is designed to measure and convert analog signals from primary converters (temperature, pressure, humidity, etc.) into the value of the measured physical quantity, as well as register measuring information in the device's memory and then transfer it to a computer (RS 485 or USB) for visualization in the form of tables and graphs. The meter-recorder is a microprocessor-based meter equipped with a non-volatile storage device and a real-time clock. The device has the ability to work as a network device (up to 20 network devices at the same time) or stand-alone with subsequent connection to computers (laptop) for reading data. The operating conditions of the meter IS-203.4 Ambient temperature, °C: -30...+50. Relative humidity, %: up to 90. Atmospheric pressure, kPa: 70...106.7.
Produced in: Kolomna, Moscow region
UShS "Tapirus" with cover and supports
UShS "Tapirus" with cover and supports
from 18 000 ₽
The UShS TapiRus is designed to replace numerous templates and devices used in visual and measuring quality control of welded joints. It is approved as a means of measuring the geometric parameters of welded joints and surface defects during visual and measuring control (VIC) and supplied with verification. It allows you to determine most of the geometric parameters of welded joints and surface defects: the width and convexity of the seam, the depth of the cut, the amount of edge displacement, the angle of the angular seam, the angle of the bevel and the gap, etc. Equipped with supports that allow you to uniquely position the template on a curved surface. To carry out measurements with an error of 0.1 mm, scales with a vernier are applied to the TapiRUS surface. It contains a number of gauges for assessing the smooth transition from the deposited to the base metal, the size of the cathets, radii and angles of cutting edges. Equipped with a probe with a replaceable measuring needle to determine the size of gaps and heights / depressions. The development, preparation for production and manufacture of TapiRus were carried out exclusively in digital format. The latest laser and additive technologies are used in the production of TapiRUS: high-precision laser cutting machines in inert gas; five-axis CNC machining centers; ultra-precise color laser engraving of the entire product assembled; laser stereolithography (SLA) is a technology of layer–by-layer synthesis of a material from a liquid photopolymer. Advantages Easy to install. Accurate positioning along the normal to the surface of the object of control and stability of the position when performing measurements. Functionality. Measurement of most geometric parameters of welded joints and surface defects. Measurement accuracy. The measurement error on the template scales does not exceed 0.1 mm. Modernity. Online calculator ergonomic accessories smart version. More detailed information can be found on the website tapirus.info MEASURED PARAMETERS AND DEFECTS VIC at the stage of input control wall thickness depth of corrosion ulcers on the base metal the depth of corrosion ulcers on the weld the depth of scratches (risks), a bully on the base metal edge bevel angle the amount of blunting geometric parameters of the dent VIC during assembly (preparation for assembly) edge offset withdrawal (angularity) of edges the gap in the cutting the height of the potholders angular displacement VIC in the welding process (surfacing) edge offset height of the root (filling) layer withdrawal (angularity) of edges angular displacement VIC of finished welded joints (structures) edge offset angular displacement the height of the reinforcement of the seam the height of the bulge (when welding elements of different thickness) the width of the reinforcement of the seam withdrawal (angularity) of edges the depth of the sinking between the rollers incomplete filling of the cutting edges scaliness of the seam surface smooth transition undercut depth seam crater depth technical specifications Measured parameter Scale Range,mm Error, mm Depth, mm H 0...20 ±0.1 (in the range 0...10 on), ± 0.5 (in the range over 10...20) Height, mm H 0...6 ±0.1 Width, mm W 0...55 ±0.1 (in the range 0...10 on), ± 0.5 (in the range over 10...20) Clearance, mm N 0...5 ±0.1 Dullness, mm F, G 0...25 ±0.5 Specifications Overall dimensions, mm, no more (without supports) 115x85x15 ± 0.5 (with supports) 115x85x42 ±0.5 Average time to failure, cycles, at least 55,000 Weight, kg, not more than 0.22 Average service life, at least 1 year
Produced in: Moscow
Laboratory electronic thermometer LT-300-N-TS
Laboratory electronic thermometer LT-300-N-TS
The measurement range is -50...+300 °C. Up to +200 °C resolution 0.01 °C, error ±0.05 ° C.
Produced in: Tomsk
Gamma radiation dosimeter DKG-03D "Grach"
Gamma radiation dosimeter DKG-03D "Grach"
Purpose: measurement of the ambient dose equivalent of N*(10) gamma radiation; measurement of ambient dose equivalent of N*(10) gamma radiation (operator dose).
Doza
Zelenograd
Produced in: Moscow