Wall-mounted high table LAB-PRO SPKv 120.80.90 SS
Wall-mounted high table LAB-PRO SPKv 120.80.90 SS
Combined working surface: STEEL main table top (single stainless steel module with anti-spill side) with a depth of 650 mm / auxiliary table top made of TRESPA material with a depth of 150 mm Length, mm: 1200 Depth, mm: 800 Height, mm: 900 BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Rear side boxes Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT110
DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT110
Irradiator with a typical collimator Rotary drum magazine sources in tungsten and lead protection Software control of the movement of sources and positioning of the mobile platform An alarm and blocking system, radiation monitoring system to ensure the safety of the installation Control from the operator panel or computer with verification automation functions
Produced in: Belarus, Minsk
Enzymes for biotechnology
Enzymes for biotechnology
from 1 350 ₽
Field of application: Cloning of restriction fragments. Connecting DNA fragments with blunt ends.
BIOLABMIKS
Novosibirsk
Produced in: Novosibirsk
Frequency comparator CHK7-1011
Frequency comparator CHK7-1011
Frequency comparators CHK7-1011 and CHK7-1011/1 can also be used as frequency and time standards with frequency correction based on GLONASS/GPS signals as sources of highly stable signals in various frequency measuring systems. Comparators have a built-in device for processing measurement data based on a microcomputer, which provides statistical processing of the results of frequency and time measurements, and a device for displaying information based on a color TFT display. The built-in diagnostic system allows you to quickly determine the operability and condition of the main comparator devices with information output to the built-in display screen. Comparators are available in three versions and differ in composition and functions performed. Comparators have a basic set of devices (modules), including a frequency comparator, a power supply module and a device for processing and displaying information based on a microcomputer and a color TFT display. The frequency comparator CHK7-1011 has a built-in SRNS receiver and a highly stable rubidium frequency standard Ch1-1014 with the function of correcting the actual frequency value by signals from satellite radio navigation systems GLONASS or GPS. The comparator forms its own time scale with the ability to synchronize on any external time scale received by the SRNS receiver built into the device. The device has two modes for measuring the deviation of the generated time scale: from the time scale of the built-in SRNS receiver and from the external time scale. Information about the current time received from the SRNS receiver is displayed on the comparator display screen, and is also transmitted to the consumer via the RS-485 interface. All the above-mentioned features make the frequency comparator CHK7-1011 a unique measuring device in the field of frequency and time measurements. The frequency comparator CHK7-1011/1 has a highly stable rubidium frequency standard Ch1-1013 and can be used as a frequency and time standard as a source of highly stable signals in various frequency measuring systems. The frequency comparator CHK7-1011/2 does not include any additional devices. To carry out measurements with it, it is necessary to use a highly stable signal of the reference frequency from an external RF or hydrogen frequency standard. For the convenience of users, apart from the keypad, they can also exercise control of the functions of the devices with a mouse-type manipulator included in the delivery package. Comparators provide access to measurement data over an Ethernet network.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Tablet for determining blood groups P-50 white, ind.up.
Tablet for determining blood groups P-50 white, ind.up.
from 137 ₽
It is intended for determining blood groups by direct agglutination reaction and conducting tests for compatibility of the donor and recipient. The P-50 tablet is made of impact-resistant polystyrene of the UPM-0508 brand. The surface of the tablet has the property of forming a regular flat drop. The wells have sides that prevent the spreading of reagents. Alphanumeric marking facilitates the organization of registration of analysis
MiniMed
Suponevo
Produced in: Bryansk region
Liquid low-temperature thermostat CRYO-VT-01
Liquid low-temperature thermostat CRYO-VT-01
As external consumers, thermostatic circuits of laboratory chemical reactors, measuring instruments and other equipment can be connected to the thermostat. Feed pump for external closed-type thermostating systems. Operating temperature range -30...+100 °C. Stability and uniformity of temperature in the working bath is not worse than ± 0.01 ° C. Bath volume 18 l Overall dimensions 440x700x640 mm The open part of the bath is 115x190 mm Bath depth 300 mm Weight 57 kg Power consumption 3.5 kW
Produced in: Tomsk
ZVPlE-630 Flat Electric vacuum Shutter
ZVPlE-630 Flat Electric vacuum Shutter
The ZVPlE-630 shutter consists of a housing with connecting flanges, a shutter mechanism, a lip seal to ensure the tightness of the drive element, cover, and electric drive. The shutter mechanism consists of a carriage, an upper and lower flap, which are pulled together by springs and balls. The carriage moves along the housing guides on bearings. The ZVPlE-630 shutter is opened and closed both by electric drive and manually using a flywheel. To switch to manual control mode, there is a switching device on the electric drive. The manual drive is used to adjust and adjust the shutter. ZVPlE-630 valves are manufactured in climatic versions UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69.
Produced in: Kazan
Green Laser Module KLM-A532-5-5 532nm 5mW dot
Green Laser Module KLM-A532-5-5 532nm 5mW dot
from 13 184 ₽
KLM-A532-5-5 laser modules are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Exhaust cabinet for working with LVZH LAB-PRO SHVLVZH 150.74.230 KG
Exhaust cabinet for working with LVZH LAB-PRO SHVLVZH 150.74.230 KG
BASIC EQUIPMENT Working box the front guide posts are aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel. AISI 304 steel rear, upper, side panels – metal painted with powder paint (RAL 7035) with the texture of shagreen leather 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – tempered glass in an aluminum frame on the top panel: 4 anti-explosion the valve lamp LED dust– and moisture-proof (2X10W IP65) is separated from the working space by tempered glass with a thickness of 4mm flange d=250mm (the distance from the back panel to the center of the flange is 170mm) switching box with automatic emergency power off 16A easily removable exhaust visors 3 exhaust levels on the rear panel: 4 holes d =22mm with plugs made of stainless steel for the installation of additional pipes or taps technological hole d=50mm with a plastic plug counterweights are placed in the front pillars-pylons and are easily serviced Frame base metal frame with a pedestal, painted with powder paint (RAL 7035) with a texture of shagreen leather: double metal facades with a noise damper, opening angle 270° handles – polypropylene 2 compartments with locks 1 shelf with the possibility of installation on three levels in any of the compartments flange d=100mm service panel – metal box painted with powder paint (RAL 5023) with the texture of shagreen leather: adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
RELAY PROTECTION UNITS FOR DIGITAL SUBSTATION OF THE IED-EP+ SERIES
RELAY PROTECTION UNITS FOR DIGITAL SUBSTATION OF THE IED-EP+ SERIES
A series of modern intelligent relay protection, automation and alarm units PARMA IED-EP+ is designed for use in networks with a voltage from 6 to 750 kV
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Verification module PM-10
Verification module PM-10
The composition of the PM-10 verification module: Wattmeter of passing power M2-35; Complex transmission and reflection coefficients meter "OBZOR-804/1"; Universal voltmeter V7-81 (2 pcs.); High-frequency signal generator G4-229; High-frequency signal generator G4-230; DC power supply B5-79/1 (2 pcs.); AC power source B2-7 (2 pcs.); The measure of DC electrical resistance is multi-valued MS3070-3, CT 0.005; The measure of DC electrical resistance is multi-valued MS3055, CT 0.02; Single-digit electrical resistance measures MS3080 (0.1; 1 ohm, CT 0.005); Thermoelectric voltage converter 0.5 V; Kit for measuring coaxial connectors KISK-7M; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical and radio engineering quantities: Operating frequency range from 0.03 to 17.85 GHz Passing microwave power from 0.01 to 10 MW VSWR of the microwave tract from 1.05 to 3 Constant electrical voltage from 10 MV to 1000 V Alternating electric voltage from 1 mV to 750 V Thermoelectric voltage comparison from 0.1 to 0.5 V Ranges of reproduction of electrical quantities: Constant electrical voltage from 1 to 120 V Resistance to direct electric current from 0.01 to 122222.21 ohms Measurement errors of electrical and radio engineering quantities: Passing microwave power ± (1.5 - 2.3) % VSWR of the microwave path ± (4,15 – 10) % Constant electrical voltage ± (0.003 – 20) % Alternating electric voltage ± (0.09 - 15) % Thermoelectric voltage comparison ± (0.01 – 0.1) % Errors in the reproduction of electrical quantities: Constant electrical voltage ± (100 – 200) mV Resistance to direct electric current CT 0.005; 0.02 General technical characteristics: The area occupied by the module is 4 – 8 m2 Weight, not more than 340 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, not more than 2000 VA
Produced in: Moscow
Measuring and diagnostic complex PKSOD-M
Measuring and diagnostic complex PKSOD-M
The proposed measuring and diagnostic complex is designed to: - provide monitoring of the technical condition of electric drive valves of nuclear power plants; – detection and identification of malfunctions of components and equipment of electric drive valves at an early stage of their occurrence; – issuance of measurement results and diagnostics of electric drive valves to the operational personnel of the station.
Produced in: Rostov-on-Don