Search

3959 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 552
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 108
    Additional
    Loading...
View:
3959 products
Vacuum drying cabinet with automatic control SNVS-90/3.5
Vacuum drying cabinet with automatic control SNVS-90/3.5
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with the appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing of devices under low pressure conditions under various temperature conditions.
Produced in: Tula
Table island high LAB-PRO SOCv 90.150.90 TR
Table island high LAB-PRO SOCv 90.150.90 TR
One-piece table top: TRESPA TopLabPlus 16 mm Length, mm: 900 Depth, mm: 1500 Height, mm: 900 BASIC EQUIPMENT The base is a collapsible metal frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Four easily removable screens (RAL 7035) and two non-removable (RAL 5023) Hidden fasteners Adjustable supports (0-40 mm) A set of end boxes-plugs
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Cylinder 2-10-2 with glass base and lid
Cylinder 2-10-2 with glass base and lid
from 350 ₽
Designed for dispensing volatile liquids. The applied scale of brown or white colors is completely resistant to any influences. TU 9464-013-52876351-2014, GOST 1770-74, pack.12/288 pcs, MiniMedProm Manufactured according to specifications 9464-013-52876351-2014 in accordance with the technical requirements of GOST 1770-74. The products are made of chemical laboratory glass according to GOST 21400. Version 2, accuracy class 2. RU No. RZN 2016/4740 of 10/25/2021
MiniMed
Suponevo
Produced in: Bryansk region
Submersible smart probe L=150 mm SZPG.150M (d=2 mm)
Submersible smart probe L=150 mm SZPG.150M (d=2 mm)
from 11 454 ₽
The submersible smart probe L=150 mm SZPG.150M (d=2 mm) is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor, Android program. Operating conditions of the SZPG.150M smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPG.150M smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect external power. Possibility of calibration.
Produced in: Kolomna, Moscow region
Trace Searcher Success AG-309.15M (frost-resistant)
Trace Searcher Success AG-309.15M (frost-resistant)
from 186 990 ₽
The trace searching kit is designed to accurately determine the location and depth of underground utilities (power and signal cable lines, reinforced fiber-optic lines, pipelines made of electrically conductive materials), troubleshooting cable lines, and also allows you to conduct a survey of the area in the shortest possible time and with great reliability before excavation and to prevent damage to engineering communications. As part of the kit, the receiver is in the form of a monoblock with a frost-resistant LCD display, which displays an image of the route and automatically calculates the depth of the communication up to 10 m, as well as the current in the line. Compact stand-alone generator with display and built-in induction antenna. The output power of the generator is up to 20 watts and the range of operation is up to 3 km.
Produced in: Kolomna, Moscow region
Green DPSS Laser 505 nm KLM-505-x
Green DPSS Laser 505 nm KLM-505-x
DPSS lasers of the KLM-505/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
TL-1MP Eddy Current Thickness Gauge
TL-1MP Eddy Current Thickness Gauge
from 1 110 000 ₽
The principle of operation of the electroplating thickness gauge: A converter with an induction coil on a ferrite core generates a high-frequency signal (frequency 1 MHz), which is used to create an alternating magnetic field. As the converter approaches the conductive surface, an alternating magnetic field creates eddy currents, the magnitude of which depends on the characteristics of the metal base and the thickness of the coating. In turn, eddy currents create their own electromagnetic field, which can be received by an induction coil. The resulting signal enters the amplitude detector, after which it is transmitted to the processing unit, where it is digitized and displayed on the device readout. In addition to signal conversion, the processor is used to set the required gain, as well as the initial voltage offset, depending on the characteristics of the materials in the controlled object. Features of the device design and advantages of the measurement method The TL-1MP eddy current thickness gauge consists of an electronic unit with a display, a power supply and a converter. The device is controlled using four buttons located on the front panel of the electronic unit. The converter can be disconnected from the electronic unit during transportation or for convenience of storage. The advantages of the device include: - convenience and ease of operation; - small size and light weight, allowing the TL-1MP to be used in difficult conditions with limited access to the controlled area of the facility; - high measurement accuracy; - factory setting of the measuring instrument to the customer's requirements; - high degree of localization of defects due to the small size of the converter. Scope of application: The service life of metal parts and components of mechanisms used in mechanical engineering is largely determined by their resistance to corrosion and surface wear. However, not all metals are sufficiently resistant to external destructive influences. Therefore, various electroplating coatings made of zinc, nickel, chromium, cadmium, tin, copper, silver and other metals are used to protect them. Even small fluctuations in the thickness of protective coatings can significantly affect the performance characteristics of parts, their service life, and interaction with other components. Therefore, measuring the thickness of the metal coating applied by the electrochemical method is important when conducting quality control of products. The use of the TL-1MP eddy current thickness gauge allows non-destructive quality control of electroplating coatings on the surface of metal parts in mass production conditions with special requirements for product quality. The device detects even small mechanical defects, the effects of abrasion, erosion, corrosion on the surface. Due to its ease of use, efficiency and reliability, eddy current thickness measurement is a standard method of quality control of products with electroplated coatings in such industries as mechanical engineering, aerospace industry.
Produced in: Moscow
Clamps for ISO-K
Clamps for ISO-K
The clamp connection (DIN 28 404 and ISO 1609) allows connecting components from DN 63 to DN 630 in any position, on any fixed flange regardless of the location of the bolt holes.
Produced in: Kazan
Measuring step attenuator D1-29
Measuring step attenuator D1-29
The device replaces the devices for checking the attenuators D1-13A and D1-25. D1-29 is a step attenuator with a range of attenuation from 0 to 110 dB with a step of 10 dB, operating in the frequency range from 0 to 150 MHz. The device consists of a housing with damping cells and a switch with a counting device. The housing contains coaxial input and output connectors, as well as additional connectors "40 dB" and "80 dB", necessary for the verification of the device. Technical specifications Operating frequency range 0 – 150 MHz Difference attenuation setting range (after 10 dB) 0 – 110 dB Input electrical resistance to direct current 50 ± 0.1 ohms The output electrical resistance to direct current when connected to the load input is 50 ± 0.1 ohms 25 ± 0.1 ohms The main absolute error of the difference attenuation setting relative to the 0 dB mark at direct current ± (0.002 - 0.02) dB The main absolute error of the difference attenuation setting relative to the 10 dB mark in the frequency range up to 30 MHz ± (0.004 - 0.9) dB The main absolute error of the difference attenuation setting relative to the 10 dB mark in the frequency range over 30 to 150 MHz ± (0.09 - 3.0) dB The maximum permissible value of the electrical voltage (DC or AC) at the input of the attenuator 3 In the operating temperature range from 5 to 40 ° C Overall dimensions, mm 149x95x149 Weight, not more than 3 kg
Produced in: Moscow
AF011B Microassembly
AF011B Microassembly
A high-speed signal limiter amplifier. Designed for use in electronic counting frequency meters. Description: The magnitude of the input signals for selecting the switch input and inverting the signal of the limiter amplifier at a supply voltage of ± 5 V: - logical "0" not more than 0.2 V; - logical "1" at least 4.8 V. The value of the input signals of switching on / off the switch at a supply voltage of ± 5 V: - logical "0" no more than 3.3 V; - logical "1" at least 4.1 V. The magnitude of the output signals of the switch at a supply voltage of ± 5 V and a load of 300 ohms connected to zero potential: - logical "0" from 3.1 V to 3.4 V; - logical "1" from 4.0 V to 4.3 V. The minimum input voltage of the sinusoidal shape in the frequency range from 10 Hz to 200 MHz should be no more than 30 mV. The maximum input voltage of the sinusoidal shape in the frequency range from 10 Hz to 200 MHz must be at least 1 V. The value of the supply voltage: - positive 5±0.2 V; - negative -5±0.2 V. The current consumption should be no more than: - from a positive power source 110 mA; - from a negative power supply 35 mA.
MNIPI
Minsk
Produced in: Belarus, Minsk
Laboratory flask
Laboratory flask
from 433 ₽
Designed for filtration, evaporation, distillation, distillation, distillation and synthesis in laboratory conditions. Variants of execution: To-1-100-29/32 TU 9464-019-29508133-2015 To-1-1000-29/32 TU 9464-019-29508133-2015 To-1-10000-45/40 TU 9464-019-29508133-2015 To-1-2000-29/32 TU 9464-019-29508133-2015 To-1-250-29/32 TU 9464-019-29508133-2015 To-1-50-29/32 TU 9464-019-29508133-2015 K-1-500-29/32 TU 9464-019-29508133-2015 TO-1-4000-45/40 K-1-6000-45/40
MiniMed
Suponevo
Produced in: Bryansk region
Universal indicator paper
Universal indicator paper
It provides high analytical accuracy and is convenient for use and storage.
EKROSKHIM
Saint Petersburg
Produced in: Saint Petersburg