Search

458 products
View:
  • Selected: 1
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Areas of use
    Loading...
  • 105
    Item names
    Loading...
  • 42
    Manufacturer
    Loading...
  • 30
    Made in
    Loading...
  • 48
    Additional
    Loading...
View:
458 products
Vacuum tube MiniMed with sodium citrate 3.8%, 4.5 ml,13*100 mm, blue, PET,pack.100 pcs,
Vacuum tube MiniMed with sodium citrate 3.8%, 4.5 ml,13*100 mm, blue, PET,pack.100 pcs,
from 693 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Research material............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K2-EDTA and separation gel, 3 ml, 13×100mm, purple, glass, pack.100 pcs,
Vacuum tube MiniMed with K2-EDTA and separation gel, 3 ml, 13×100mm, purple, glass, pack.100 pcs,
from 1 339 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K2-EDTA, 4 ml, 13×75mm, purple, PET, pack.100 pcs
Vacuum tube MiniMed with K2-EDTA, 4 ml, 13×75mm, purple, PET, pack.100 pcs
from 690 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... stabilized EDTA whole blood /EDTA plasma. Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Atomic absorption spectrometer "MGA-1000"
Atomic absorption spectrometer "MGA-1000"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 900 Spectral resolution, nm, no more: - in the range from 190 to 600 nm inclusive - in the range over 600 to 900 nm inclusive 2 3 Limit of detection of manganese, pg, no more than 3 Nickel detection limit, pg, no more than 20 The time of setting the operating mode of the spectrometers, min, no more than 15 The time of continuous operation of the spectrometers, h, no less than 8 The spectrometers are powered by a three-phase alternating current network: - rated supply voltage, V - frequency, Hz 380 (50 ±1) Overall dimensions of the spectrometer, mm, no more than 800 x 475 x 310 Mass of the spectrometer, kg, no more than 50 Power consumed by spectrometers, kV * A, no more: - in standby modes and settings of analytical parameters - in atomization and purification modes 0.1 6 Average time to failure, h, not less than 4000
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with sodium citrate 3.8%, 2.7 ml,13*100 mm, blue, PET,pack.100 pcs,
Vacuum tube MiniMed with sodium citrate 3.8%, 2.7 ml,13*100 mm, blue, PET,pack.100 pcs,
from 330 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Material for research............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Biosafety cabinet BA-Safe 150
Biosafety cabinet BA-Safe 150
Biosafety cabinet Belaquilon BA-safe 150 (for biological protection). The Class II Type A2 biological safety cabinets are designed to reduce the risk of infection to the operator during work with dangerous or potentially dangerous microorganisms and to protect the specimen, is the result of the production of biological safety cabinets based on user feedback. Technical specifications Voltage, frequency, 230V ±10%/Hz Engine 1-phase 230 V, 50 Hz, speed 1150 rpm UV lamp TUV UV lamp, UV lamp timer, 6000 hours of operation Wavelength 254 nm Number of LEDs, pcs at least 380 Lighting power, 55 W Work area illumination at least 1500 lux, brightness adjustable, color of luminous flux 6000 K (cold white light) Internal dimension of the working area, at least 1530×504 mm Working height of front screen elevation, 200 mm Max. height of front screen elevation, 510 mm Frontal screen position alarm Audible position warning. Warning appears on display Outer dimension, mm 1668.5x766.2x1506.6 Height of base, mm 690
Produced in: Belarus, Minsk
Vacuum tube MiniMed with K2-EDTA, 7 ml, 13×100mm, purple, glass, pack.100 pcs
Vacuum tube MiniMed with K2-EDTA, 7 ml, 13×100mm, purple, glass, pack.100 pcs
from 1 235 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Human IFN-beta Antibody
Human IFN-beta Antibody
from 21 000 ₽
The family of interferons (IFNs) are glycoprotein proteins that have a wide range of biological activity, including antiviral, antitumor, and also exhibit antiproliferative and proapoptotic properties. There are three known types of interferons: type I IFN / type I IFN (α, β, ω, τ, κ, ˜, and δ), type II IFN / type II IFN (γ), and type III IFN / type III IFN (λ1 (IL-29), λ2 (IL-28A), λ3 (IL-28B)). The classification of interferons by type is based on their interaction with the corresponding cellular receptors. Type I and II IFN receptors are present on the surface of most human cells, while type III IFN receptors are highly expressed on hepatocytes, but absent on the surface of microvascular endothelial cells, adipocytes, fibroblasts, and cells of the central nervous system.
Produced in: Moscow
Vacuum tube MiniMed with coagulation activator, 3ml, 13×100mm, orange, PET, pack.100 pcs,
Vacuum tube MiniMed with coagulation activator, 3ml, 13×100mm, orange, PET, pack.100 pcs,
from 665 ₽
The walls of the tubes are coated with a dry clot formation activator (silicon dioxide) to accelerate blood clotting. Mixing blood with it does not affect the result of tests. The acceleration of the blood clotting process significantly reduces the preparation time of the biological sample. Material for research............... blood serum Scope of application............................ blood serum research in biochemistry, immunology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with sodium citrate 3.8%, 3.6 ml,13*75 mm, blue, PET,pack.100 pcs,
Vacuum tube MiniMed with sodium citrate 3.8%, 3.6 ml,13*75 mm, blue, PET,pack.100 pcs,
from 693 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Material for research............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with sodium citrate 3.8%, 3.6 ml,13*100 mm,blue, glass, pack.100 pcs
Vacuum tube MiniMed with sodium citrate 3.8%, 3.6 ml,13*100 mm,blue, glass, pack.100 pcs
from 1 086 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Research material............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region