LIQUEFIED GAS METERING VALVE
LIQUEFIED GAS METERING VALVE
The metering valve for the analysis of liquefied gas (KDSG) is designed for the introduction of liquefied gas or other liquid under excessive pressure into the evaporator of the chromatograph. KDSG is a 4-way crane, in which a dose of a certain volume is installed. The tap is installed on the evaporator of the chromatograph. A dose of any volume can be installed on the tap. Dose change can be performed by the operator. The amount of the dose volume is indicated on the tag. Technical specifications The dose volume is from 0.25 to 4.0 µl (at the request of the consumer, the dose volume can be increased up to 10 µl). The tap temperature is no more than 150 °C. The pressure in the crane line is not more than 0.48 MPa. The angle of rotation of the crane handle is 90 °C.
Produced in: Yoshkar-Ola, Mari El
DISPENSER "EVEN 4000"
DISPENSER "EVEN 4000"
The dispenser "DAZH 4000" is designed for automatic insertion of liquid samples into the evaporator of the gas chromatograph, provides: control from the software, setting variable parameters of algorithms for washing and sample entry, storing the operating parameters of the dispenser in the method. Technical characteristics: The number of vials in the carousel, pcs up to 30 The volume of installed vials, ml 0.1-2ml Number of injections from one vial 1-99 Replaceable syringes in volume, ml 10, 100, 250, 500 The volume of the injected sample, ml : from 0.01 to 500 The discreteness of setting the sample volume, µl: from 0.01 to 1 Sampling and insertion rate, µl/s: from 0.01 to 5000 The speed of needle insertion into the evaporator, discret 3 Immersion depth in the vial and evaporator, variable up to the length of the syringe needle, mm 1 – 99 The discreteness of the dive depth setting, mm 0,1 The number of pumping during sampling 0-15 Number of solvent washes 0-15 Needle exposure time in the evaporator, sec 0-99 The discreteness of setting the needle shutter speed, sec 1,0 Sample input modes Simple insertion, Sandwich, Solvent sandwich, Sandwich with internal standard Flushing mode From the vial Supply voltage, V (frequency, Hz) 220 (50) Power consumption, W 154 Weight, kg, no more 2,9 Overall dimensions, mm 175x270x420 Communication with the computer Ethernet
Produced in: Yoshkar-Ola, Mari El
METERING VALVE FOR GAS SAMPLES
METERING VALVE FOR GAS SAMPLES
The metering valve for the introduction of gas samples is designed for the introduction of gas under excessive pressure into the chromatograph. Cranes differ in the number of moves (4, 6, 8, 10, 12) and have two provisions "Selection" — "Analysis". In addition to dosing, cranes can be used to switch chromatographic columns, elements of gas circuits, etc. The tap can be installed either on the side panel of the chromatograph, or directly into the analytical module instead of, or together with the evaporator of the chromatograph, while it is used as a back-purge tap or for hot sample entry. Additionally, the tap for hot entry can be equipped with heated pipelines. technical specifications The dose volume is from 0.25 to 5.0 ml (at the request of the consumer, the dose volume can be increased to 10 ml and reduced to 0.1 ml). The maximum temperature of the tap is no more than 160 °C. The pressure in the crane line is not more than 0.48 MPa. The angle of rotation of the crane handle — depending on the number of strokes.
Produced in: Yoshkar-Ola, Mari El
HK-250-1 POZIS Blood storage refrigerator
HK-250-1 POZIS Blood storage refrigerator
from 29 605 ₽
Refrigerant R600a Total volume, l. 250 Number of compressors, pcs. 1 Height, mm 1300 Depth, mm 610 Width, mm 600 Weight, kg., no more 50 Rated power consumption, W 200 Maximum rated power, W 225 Voltage, 220 V Warranty, 1 year Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Cold storage Auto refrigerator defrosting system Temperature in the refrigerator, °C +2...+6 Accuracy of temperature maintenance ±2°C Thermal card: yes Efficiency and energy consumption Electricity consumption, kWh/day, no more than 0.74 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 49 Gross weight of the product, kg 52.5 Volume of packaging, m3 0,557 The length of the package, m 0.65 The width of the package, m 0.63 The height of the package, m 1.36
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
HK-250-2 POZIS Blood storage refrigerator
HK-250-2 POZIS Blood storage refrigerator
from 32 621 ₽
Refrigerant R600a Total volume, l. 250 Number of compressors, pcs. 1 Height, mm 1300 Depth, mm 610 Width, mm 600 Weight, kg., no more 50 Rated power consumption, W 200 Maximum rated power, W 225 Voltage, 220 V Warranty, 1 year Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Cold storage Auto refrigerator defrosting system Temperature in the refrigerator, °C +2...+6 Accuracy of temperature maintenance ±2°C Thermal card: yes Efficiency and energy consumption Electricity consumption, kWh/day, no more than 0.74 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 49 Gross weight of the product, kg 52.5 Volume of packaging, m3 0,557 The length of the package, m 0.65 The width of the package, m 0.63 The height of the package, m 1.36
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
Spectrophotometer UV-VIS PB2201
Spectrophotometer UV-VIS PB2201
1 supp.
Measuring functions Measurement of absorption, transmission, and reflection spectra Measurement of optical density, transmission coefficient and reflection coefficient at fixed wavelengths Determination of concentration at one, two, three wavelengths by factor, standard, schedule Multi-wave kinetic measurements Determination of concentration by programmed methods Calculation of color and chromaticity coordinates UVI spectrophotometers "SOLAR" operate in the ultraviolet, visible and near infrared regions of the spectrum. They are used in scientific laboratories, healthcare institutions, veterinary medicine, pharmaceuticals, ecology, biology, etc., in laboratories for quality control of products and raw materials in various sectors of the economy (industrial enterprises, agriculture, food industry, etc.) Removable cuvette holders and set-top boxes Accurate measurements Cost-effectiveness Touch screen Built-in printer Software support
SOLAR
Minsk
Produced in: Belarus, Minsk
HK-400-2 POZIS Blood storage refrigerator
HK-400-2 POZIS Blood storage refrigerator
from 59 820 ₽
Total volume, l. 400 Number of compressors, pcs. 1 Height, mm 1950 Depth, mm 610 Width, mm 600 Weight, kg., no more 72 Rated power consumption, W 300 Maximum rated power, W 315 Voltage, 220 V Warranty, 1 year Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Additional transparent doors that prevent unwanted air exchange between compartments. Cold storage Auto refrigerator defrosting system Temperature in the refrigerator, °C +2...+6 Accuracy of temperature maintenance ±2°C thermal card: yes Efficiency and energy consumption Electricity consumption, kWh/day, no more than 1.42 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 72 Gross weight of the product, kg 76.5 Volume of packaging, m3 0.827 The length of the package, m 0.65 The width of the package, m 0.63 The height of the packaging, m 2.02
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
VacProtect VPA-200 POZIS Active refrigerator for storing vaccines
VacProtect VPA-200 POZIS Active refrigerator for storing vaccines
from 114 333 ₽
Electronic control Refrigerant R600a Total volume, l. 200 Number of compressors, pcs. 1 Height, mm 1660 Depth, mm 860 Width, mm 730 Weight, kg., no more 100 Rated power consumption, W 160 Voltage, 220 V Warranty, 1 year Cold storage Temperature in the refrigerator, °C +2...+8 Freezer Thermal card: yes Cold storage battery, pcs 51 Efficiency and power consumption Electricity consumption, kWh/day, not more than 0.35 Frequency, Hz 50
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
Liquid chromatograph "Lumachrom-M"
Liquid chromatograph "Lumachrom-M"
1 supp.
The liquid chromatograph "Lumachrom-M" provides maximum automation of the analysis. The device is controlled using specialized software, which in combination with the continuous eluent supply mode and the autosampler gives the maximum level of autonomy of operation. In addition, such a solution minimizes labor costs and the influence of the human factor. The unique design solutions of the chromatograph provide continuous pulsation-free flow of the mobile phase in both isocratic and gradient modes, as well as the ability to work with any column sizes. Thanks to the improved technical characteristics on the Lumachrom-M device, it is possible to implement a wider list of techniques and GOST compared to previous models.
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Atomic absorption spectrometer "MGA-1000"
Atomic absorption spectrometer "MGA-1000"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 900 Spectral resolution, nm, no more: - in the range from 190 to 600 nm inclusive - in the range over 600 to 900 nm inclusive 2 3 Limit of detection of manganese, pg, no more than 3 Nickel detection limit, pg, no more than 20 The time of setting the operating mode of the spectrometers, min, no more than 15 The time of continuous operation of the spectrometers, h, no less than 8 The spectrometers are powered by a three-phase alternating current network: - rated supply voltage, V - frequency, Hz 380 (50 ±1) Overall dimensions of the spectrometer, mm, no more than 800 x 475 x 310 Mass of the spectrometer, kg, no more than 50 Power consumed by spectrometers, kV * A, no more: - in standby modes and settings of analytical parameters - in atomization and purification modes 0.1 6 Average time to failure, h, not less than 4000
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M"
Mercury analyzer "RA-915M"
1 supp.
Technical specifications: Measuring range of mass concentration of mercury vapors in the air, ng/m3 from 20 to 20000 Limits of permissible basic relative error, d0, % ± 20 The limit of permissible relative standard deviation of the analyzer output signal, %5 The limit of the permissible value of the mean square deviation (SKO) of the zero signal, ng/m3 2 Drift of the zero signal of the analyzers in 5 minutes, ng/m3, no more than 2 The limit of permissible change of analyzer readings for 8 hours in fractions of d0 0.5 Time to establish the readings, s, no more than 20 Time of analyzer output to the mode, min, no more than 20 Volumetric flow rate of the analyzed air at the analyzer inlet, dm3/min, not less than 10 Volumetric air flow at the outlet of the gas analyzer system with the inlet blocked, dm3/min, not more than 0.3 Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 The limit of permissible additional error due to changes in ambient temperature within the operating range for every 10 ° C, in fractions of d0 0.5 The analyzers are powered by a built-in AC battery voltage (220 ±22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, not more than 7 Reliability indicators average time to failure, h, at least the full average life from the built-in AC battery voltage (220 ± 22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, no more than 7 Reliability indicators average time to failure, hours, at least full average service life, years, at least 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid chromatograph "LUMACHROM®"
Liquid chromatograph "LUMACHROM®"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 360 Limits of permissible absolute error of wavelength setting, nm ± 5 Detection limit of anthracene (wavelength 252 nm), ng/cm3, no more than 1 The limit of the permissible value of the relative mean square deviation of the output signal (n =5), % of the retention time over the peak area of 1.5 2 Limits of the permissible value of the relative change in the output signal (peak area) for 4 hours of continuous operation, % ± 5 Overall dimensions (LxWxH), mm, no more: 270x420x190 Weight, kg, not more than 9.5 Power consumption, V· A, not more than 50
Lumeks
Saint Petersburg