AO-3 cooler
AO-3 cooler
1 supp.
According to the requirements of the standards, the cooler is included in the list of equipment for determining humidity with pre-drying. Usually, grain samples after preliminary drying are cooled in the laboratory room to ambient temperature. However, with such cooling, the ambient temperature reaches only the surface layers of the samples, which affects the results of the analyses. The principle of operation of the cooler is based on blowing sample canopies in mesh buckets placed on a stand by a fan rotating at high speed. Advantages: Rapid cooling of samples. Stable moisture distribution. Allows you to significantly improve the accuracy of the results of determining humidity.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Purka liter MEASURE
Purka liter MEASURE
1 supp.
The principle of operation is based on measurement by filling the container for the measured product with 1 liter of grain and measuring the mass of this grain. PECULIARITIES: 1. Drop weight design no assembly required Thanks to a fundamentally new design of the purka, the determination of nature is carried out quickly. Significantly reduced analysis time. No special training of personnel is required to work on the MERA purka. 2. Stability and reproducibility of results. The stable and repeatable movement of the knives ensures the stability of the work of the purka and an accurate, stable, reproducible determination of the nature (± 1g at 10 measurements). 3. Quick and easy cleaning The convenient design of the device permits to clean it quickly and easily. Excess grain is removed into an empty container for the measured product by pressing the "RESET" button. After discarding the remaining grain, the purka is ready for the next measurement. The fundamentally new design of the MERA purka body and the automation of the analysis process allow you to quickly and easily get the result. WORK ALGORITHM: 1.Fill the hopper with grain. 2.Install the empty container for the measured product into the device. 3. Press the "START" button on the control panel. 4. Weigh a container filled with 1 liter of grain and calculate the result. 5. Reset the remaining grain by pressing the "RESET" button. METROLOGICAL CHARACTERISTICS: Indication error, g, no more than ±4.0 Variation of six dimensions, g, no more than 2.1 SPECIFICATIONS: Overall dimensions (L×W×H), mm, no more than 600×230×620 Weight, kg, no more than 48 Power consumption, V×A, no more than 100 Supply voltage with a frequency of 50±1 Hz, V 220 (+15...-20)%
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Laboratory mill BLIZZARD 3M
Laboratory mill BLIZZARD 3M
1 supp.
The principle of operation of the mills is based on the grinding of the product, rotating at high speed with a knife in combination with a cyclic rotation of the grinding unit. In order to achieve uniform grinding and homogenization of the sample, the grinding unit must be tilted during grinding. The angle of inclination is set automatically according to the selected mode. FEATURES: 1. Programmable grinding modes The laboratory mill has two grinding modes: "Sunflower" - used for grinding oilseeds. "Grain. Feed" is used for grinding grain, leguminous crops, feed and raw materials for their production. Depending on the crushed product, the operator selects the desired mode of the grinding process. The installation of the grinding mode options is carried out using a specially developed program via a PC. It is possible to install an additional grinding mode using a PC. 2.Easy operation with information display. 3. Crushing of samples with a high fat content (up to 55%). 4. Sample preparation without heating. The special design of the grinding chamber (grinding is carried out in the upper bowl made of aluminum) and the use of special knives ensure rapid grinding and minimize heating of the sample, which eliminates moisture loss. According to the test results of FSUE "UNIIM", mills are recommended for sample preparation during the analysis to determine humidity. They are part of the installation of the measuring air-thermal ASESH-8 (RU. p.31.005.A No. 56847). 5. COOLING SYSTEM without forced water cooling. For continuous comfortable operation with the cooling system, the mill is equipped with two grinding cups. 6. Grinding of various types of samples. The presence of knives of various geometries and the possibility of their quick replacement when changing the crushed product, allows the mill to be used for grinding a wide range of agricultural products – from wheat grains to soybeans and sunflower seeds, according to specially developed algorithms. Knives are included in the delivery package of the mill: knife No. 2 – for grinding oilseeds and cereals; knife No. 4 – for grinding feed and raw materials for their production; knife No. 1 – designed for chopping soybeans.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Infrared analyzer INFRASKAN 4200
Infrared analyzer INFRASKAN 4200
1 supp.
The INFRASKAN 4200 analyzer has been tested at the D.I. Mendeleev VNIIM, entered into the unified State Register of measuring instruments under No. 83050-21. All manufactured devices undergo primary verification and have the appropriate certificate. Analyzes a wide range of quality indicators (protein, moisture, quantity and quality of gluten (IDC), fat/oil content, water absorption capacity, acid number, peroxide number, m.d. phosphorizing substances, etc.) Is calibrated to assess moisture and protein in whole grains (wheat, barley). The cuvette compartment for the analysis of bulk, liquid and pasty products allows to analyse liquid vegetable oils without the use of additional devices. The built-in whiteness module allows to determine the whiteness of the product simultaneously with other quality indicators (moisture, protein, amount of gluten). A wide spectral range (400-2500nm) provides measurement of the zonal reflection coefficient to determine the whiteness of flour in accordance with the GOST 26361-2013 methodology. It is possible to calculate the amino acid composition of feed components. To organize the work of analyzers in the ECANET network, the INFRASCAN-4200 analyzer can be used as a server for storing and transmitting data. The remote access mode allows to remotely update existing calibrations, install additional calibration models and develop new calibration models for new products, as well as make adjustments to technical settings if necessary.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Spectrophotometer UV-VIS PB2201
Spectrophotometer UV-VIS PB2201
1 supp.
Measuring functions Measurement of absorption, transmission, and reflection spectra Measurement of optical density, transmission coefficient and reflection coefficient at fixed wavelengths Determination of concentration at one, two, three wavelengths by factor, standard, schedule Multi-wave kinetic measurements Determination of concentration by programmed methods Calculation of color and chromaticity coordinates UVI spectrophotometers "SOLAR" operate in the ultraviolet, visible and near infrared regions of the spectrum. They are used in scientific laboratories, healthcare institutions, veterinary medicine, pharmaceuticals, ecology, biology, etc., in laboratories for quality control of products and raw materials in various sectors of the economy (industrial enterprises, agriculture, food industry, etc.) Removable cuvette holders and set-top boxes Accurate measurements Cost-effectiveness Touch screen Built-in printer Software support
SOLAR
Minsk
Produced in: Belarus, Minsk
Device for automatic isolation of nucleic acids COLIBRI
Device for automatic isolation of nucleic acids COLIBRI
from 2 840 000 ₽
1 supp.
The open system allows you to work with reagents and laboratory plastics from various manufacturers Russian-language software Modifications: - COLIBRI 24 - the ability to select from 1 to 24 samples - COLIBRI 48 - the ability to select from 1 to 48 samples - COLIBRI 96 - the ability to select from 1 to 96 samples Range of working volumes: - COLIBRI 24 - 200 – 5000 mkl - COLIBRI 48 - 30 – 1000 mkl - COLIBRI 96 - 20 – 1000 mkl A unique format of consumable plastic - 8-hole strips and combs Two built-in thermostats The accuracy of temperature maintenance is ± 1 °C Heating/cooling - up to 100 °C / up to 35 °C Universal Thermostat Tube Unit Built-in computer Ready-made allocation protocols The time of one extraction cycle is from 11 minutes Built-in bactericidal UV lamp for interior treatment
SYNTOL
Москва
Produced in: Moscow
GeneMack Strela Automatic Nucleic Acid Isolation Station
GeneMack Strela Automatic Nucleic Acid Isolation Station
1 supp.
The Strela automatic nucleic Acid isolation station is suitable for laboratories with a small sample flow seeking to optimize workflow and improve reproducibility of results. The station is being developed and assembled in Russia. Station Features: • Separation on magnetic particles – high yield of nucleic acids and excellent purity • The quality and concentration of the resulting DNA is sufficient for all molecular applications, including NGS • Ability to work with different types of samples, including complex samples (whole blood, FFPE, cfDNA, dry blood stains, saliva, hair, nails, etc.) • Simultaneous isolation of 1 to 13 samples • About 30 minutes per allocation, depending on the protocol • No overspending of plastic – load exactly as many cartridges as you are going to allocate samples • A large number of built-in protocols, the ability to program your protocols for different cartridges • User-friendly and intuitive interface • The station is compatible with cartridges from different manufacturers • 24/7 technical support in Russian Technical specifications Device Type: Desktop automatic device Minimum load: 1 sample Maximum load: 13 samples Reagent format: Bottled and sealed in individual cartridges Protocol execution time: From 16 to 60 minutes (depending on the allocation protocol program) Dosage volume: 25-1000 µl Dosing accuracy: No more than 5% CV Control: LCD Touch screen, 7 inches, 1025x600 Software language: Russian Heating unit with temperature control: from 30C to 80C (at room temperature+ 25C) UV lamp: Available Input voltage: 220V Overall dimensions (W x L x H): 54 x 57 x 61 cm Weight: 60 kg The installation location is only indoors Ambient operating temperature 15-40°C
Aivok
Zelenograd
Produced in: Moscow, Zelenograd
LAMPIX V Portable instrument for real-time isothermal DNA amplification, 1 channel, 2×0.2 ml
LAMPIX V Portable instrument for real-time isothermal DNA amplification, 1 channel, 2×0.2 ml
1 supp.
Super-compact DNA amplifier with real-time recording of results for isothermal amplification of nucleic acids. Designed to work with 2 samples and fits in the palm of your hand.
DNA amplifier with real-time recording of results for isothermal PCR amplification of nucleic acids (LAMP and RT-LAMP). The compact device is designed to work with 2 samples, maintains the required temperature for setting up the reaction and reads the analysis result. The software that comes with LAMPIX V allows you to set analysis parameters and save the result. Wireless connection via Bluetooth is possible.
Technical characteristics of the LAMPIX V amplifier:
  • thermal block format - 2×0.2 ml;
  • number of fluorescence measurement channels - 1;
  • compatibility with dyes - FAM, SYBR Green, EvaGreen; excitation source - LED;
  • fluorescence detector - photodiode;
  • excitation source wavelength, nm - 470;
  • detection wavelengths, nm - 510-530;
  • type of tubes - 0.2 ml tubes with a flat cap;
  • temperature range, °C - 37–75;
  • temperature maintenance accuracy, °C — ±0.5;
  • interfaces for connecting to a PC/laptop - USB type C, Bluetooth;
  • power supply - external power supply 5 V / 2.5 W, power bank;
  • Software for managing and analyzing results - Win 7-10, Android;
  • dimensions, L×W×H, mm – 45x45x65;
  • weight of the device, g - 60. Delivery set: real-time DNA amplifier;
  • external power supply;
  • cable for connecting to a computer USB type C;
  • Software in English;
  • instructions in Russian;
  • PC (or laptop) not included;
  • 1 year warranty;
  • It is possible for a technical specialist to visit for training (optional).
Aivok
Zelenograd
Produced in: Moscow, Zelenograd
Liquid chromatograph "LUMACHROM®"
Liquid chromatograph "LUMACHROM®"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 360 Limits of permissible absolute error of wavelength setting, nm ± 5 Detection limit of anthracene (wavelength 252 nm), ng/cm3, no more than 1 The limit of the permissible value of the relative mean square deviation of the output signal (n =5), % of the retention time over the peak area of 1.5 2 Limits of the permissible value of the relative change in the output signal (peak area) for 4 hours of continuous operation, % ± 5 Overall dimensions (LxWxH), mm, no more: 270x420x190 Weight, kg, not more than 9.5 Power consumption, V· A, not more than 50
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared analyzer "InfraLUM® FT-12"
Infrared analyzer "InfraLUM® FT-12"
1 supp.
Technical specifications: Measurement time, 80 seconds Standard sample volume in a cuvette, 50 ml Spectral range, cm-1 from 8700 to 13200 Spectral resolution, cm-1, no more than 10 The limit of the permissible value of the absolute error of the wave number scale, cm-1 ±0,5 Analyzer warm-up time, min, no more than 30 Continuous operation time of the analyzer, h, at least 8 Overall dimensions, mm, no more than 530x450x380 Weight, kg, not more than 32 Power supply of analyzers from the AC network: AC power supply voltage, V frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, not more than 110 Average time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-105M"
Capillary electrophoresis systems "KAPEL®-105M"
1 supp.
Technical specifications: The range of working detection wavelengths, nm from 190 to 380 Limits of permissible absolute error of setting the working wavelength, nm ± 5 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 220 Overall dimensions (LXC), mm, no more 420x570x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid chromatograph "Lumachrom-M"
Liquid chromatograph "Lumachrom-M"
1 supp.
The liquid chromatograph "Lumachrom-M" provides maximum automation of the analysis. The device is controlled using specialized software, which in combination with the continuous eluent supply mode and the autosampler gives the maximum level of autonomy of operation. In addition, such a solution minimizes labor costs and the influence of the human factor. The unique design solutions of the chromatograph provide continuous pulsation-free flow of the mobile phase in both isocratic and gradient modes, as well as the ability to work with any column sizes. Thanks to the improved technical characteristics on the Lumachrom-M device, it is possible to implement a wider list of techniques and GOST compared to previous models.
Lumeks
Saint Petersburg
Produced in: Saint Petersburg