Equipment

2245 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 389
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2245 products
Pure Hydrogen Generator GVCH-9M
Pure Hydrogen Generator GVCH-9M
from 158 400 ₽
The characteristics of the device are similar to the GVCH-12D model; the difference is in the absence of a reactor to remove traces of oxygen and the performance, respectively, is 9 / hour (150 ml/min). Optionally equipped with a reactor for using hydrogen as a carrier gas. Technical specifications Purity of hydrogen in terms of dry gas is about 99.998% Concentration of water vapor at 20 OC and 1atm is no more than 5 ppm In the output pressure stabilization mode The range of the specified output pressure of hydrogen is from 1.5 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati Maximum hydrogen capacity reduced to normal conditions is 9 l/h The time of setting the operating mode, with the output turned off is no more than 15 min In the performance stabilization mode: The range of the specified hydrogen performance is from 0 to 9 l/h Maximum developed pressure in performance mode is 5.0 ati Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.015 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 1 year Average power consumption: in stationary mode is no more than 80 VA maximum (at startup) is no more than 100 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 15 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Combined mobile laboratory up to 35 kV (ETL-35K)
Combined mobile laboratory up to 35 kV (ETL-35K)
The combined laboratory up to 35 kV (ETL-35K) consists of: 1. Test facility • – Maximum rectified voltage up to 70 kV; • – Maximum AC voltage of the industrial frequency of 50 Hz to 100 kV. 2. Insulation parameters meter • – Transformation coefficient; • – No-load losses at low voltage; • – Short circuit resistance; • – Voltage and current; • – Power factor; • – Frequency of the measured voltage (current); • – Phase shift angle between voltage and current; • – Measurement of the active resistance of the windings. 3. Burning facility • – Maximum voltage up to 30 kV; • – Maximum current up to 80 A; • – Working hours are not limited; • – Switching of stages is carried out without breaking the arc at the time of switching; • – The ability to start working from any stage of burning (when working with low-voltage cables); • – Built-in afterburning. 4. High voltage pulse generator • – Output voltage 0...12 kV / 0...24 kV; • – The pulse energy at each stage is 3000 J; • – Built-in IDM for collaboration with the reflectometer. 5. Reflectometer – Supports 3 methods of determining the location of damage: • – By pulse reflectometry; • – By the method of oscillatory discharge; • – Pulse-arc method. 6. High-voltage cable defects detector • – Determining the location and depth of the cable at a depth of up to 10 m; • – Tracing at a distance of up to 10 km; • – Search for live electrical cables; • – Search for places where pipelines and cables intersect; • – Determining the places of damage to cable lines; • – Site surveys before excavation; • – Search for places of damage to the external insulation of the cable; • – GPS\GLONASS coordinates recording and mapping of found communications; • – Cable selection from the bundle; • – Search for the place of damage by acoustic method.
Produced in: Kolomna, Moscow region
Sandy bathhouse "PB" I2
Sandy bathhouse "PB" I2
from 54 251 ₽
The sand bath "PB" I2 with digital control and an increased heating area of 260x510 mm is designed for heat treatment of samples, evaporation and laboratory analysis. Optionally, the product can be equipped with a shutdown timer.
Produced in: Tula
X-ray fluorescence wavelength dispersive flowstream pulp, suspension and solution analyzer AR-35
X-ray fluorescence wavelength dispersive flowstream pulp, suspension and solution analyzer AR-35
The AP-35 analyzer is a fully automated analytical complex designed for continuous X-ray fluorescence analysis of the chemical composition of slurries and solutions in flow. The instrument has a movable software-controlled measuring head with an X-ray tube and fixed spectrometric channels (up to 8), each of which can be set up for any chemical element (from Ca to U). In operation, up to 15 flow cells are measured by the head according to a preset program. Multi channel capability (up to 15 products to be measured). Compatibility with automation systems for sampling, sample delivery, data handling and presentation, data archiving. Link to factory process control system High expressiveness, high analytical precision, low detection limits, reproducibility High reliability. The principle of operation is based on the excited fluorescence produced by the atoms of the material under analysis through the radiation of an X-ray tube. The fluorescence radiation of a particular chemical element is picked up by the crystal analyzer, and then the radiation at a specific wavelength is detected by an X-ray tube detector. The intensity of the recorded fluorescence radiation of a certain wavelength is directly proportional to the mass fraction of the chemical element in the substance under study.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
Muffle furnace LF-9/11-G2
Muffle furnace LF-9/11-G2
Design features: Programmable microprocessor; Three programs of ten steps with the ability to set the temperature, heating speed and holding time for each step; Manual heating mode with timer with sound notification and auto-off; Durable ceramic muffle; Closed heaters on four sides of the chamber; Backlit graphic display; Conveniently located control panel; Automatic shutdown of heating when opening the door; Sound and light alarm when the current temperature exceeds the limits of the permissible interval; The door opens up and faces the user with the cold side; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1100 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x150x290 mm Overall dimensions, WxHxD, not more than 525x625x620 mm Rated supply voltage, 220 V Rated power, W 5500
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Collection for storage of purified water S-500
Collection for storage of purified water S-500
from 120 000 ₽
Designed for collecting, storing and distributing purified water obtained by various purification methods, with a capacity of 500 liters and 100% stainless steel, which allowed for a long service life. Dimensions in terms of 805x780 mm Weight 48 kg
Livam
Belgorod
Produced in: Belgorod
Vacuum drying cabinet with automatic control SNVS-60/3.5
Vacuum drying cabinet with automatic control SNVS-60/3.5
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with the appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing of devices under low pressure conditions under various temperature conditions.
Produced in: Tula
LB11 Laboratory bath
LB11 Laboratory bath
It is designed for thermostating samples in glasses, flasks and other laboratory utensils in cases where high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. One workplace with a diameter of 110 mm with five steel O-rings. Stamped steel tub with a volume of 2.5 liters and a depth of 60 mm. Bath volume 2.5 l Overall dimensions 325x195x260 mm The open part of the bath is 60 mm Weight 5 kg Power consumption 2.5 kW
Produced in: Tomsk
Muffle furnace LF-15/11-G2
Muffle furnace LF-15/11-G2
Design features: Programmable microprocessor temperature controller; Three programs of ten steps with the ability to set the temperature, heating speed and holding time for each step; Manual heating mode with timer with sound notification and auto-off; Durable ceramic muffle; Closed heaters on four sides of the chamber; Backlit graphic display; Conveniently located control panel; Automatic shutdown of heating when opening the door; Sound and light alarm when the current temperature exceeds the limits of the permissible interval; The door opens up and faces the user with the cold side; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1100 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than mm 215x190x330 Overall dimensions, WxHxD, not more than mm 525x655x680 Rated supply voltage, 220 V Rated power, W 6100
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Aquarius Deionizer (in a new case)
Aquarius Deionizer (in a new case)
from 96 000 ₽
It is intended for obtaining in laboratory conditions from distilled especially pure (deionized) water used for the preparation of solutions, chromatographic samples, refueling of electrolytic hydrogen/oxygen generators and other purposes. Technical specifications The specific conductivity of the resulting water is not more than 0.20* mkSxcm Capacity is at least 6* l/h Metal ion content is not more than: Fe, Pb, Ni, Co 5*mcG/l Zn, Cd, Cu, Mn 1*mcG/l The optical density of ammonia relative to bidistilled water is no more than D - 0.01* Operating time of the replaceable cassette (total volume of purified water) is not less than 700 liters. Volume of refueled distilled water is 1 l Overall dimensions are 440x200x430 mm The mass of the refilled device is not more than 9.5 kg Working conditions: ambient temperature from +10°C to +35°C Power supply from single-phase AC 220 V., 50 Hz The power consumption is not more than 20 VA.
Produced in: Moscow
Explosion-proof drying cabinet SNOL-200
Explosion-proof drying cabinet SNOL-200
from 559 470 ₽
Explosion-proof drying cabinet SNOL-200 is designed for drying, tempering, aging, thermal testing and other types of heat treatment of various materials in an air environment at temperatures up to 240 ° C with natural or forced air convection in stationary conditions. The environment is a potentially explosive mixture of air and gases, vapors, mists of categories IIA and IIB.
Produced in: Tula
Liquid low-temperature thermostat CRYO-T-02
Liquid low-temperature thermostat CRYO-T-02
It can be used for temperature control of any extended objects. The thermostat is characterized by a large depth of the working bath and a temperature heterogeneity of ± 0.05 ° C in the entire working volume. The operating temperature range is -15...+150 °C. Bath volume 28 l Overall dimensions 430x690x1320 mm The open part of the bath is 115x185 mm Bath depth 970 mm Weight 72 kg Power consumption 3.5 kW
Produced in: Tomsk