The device for monitoring the loading of mills UKZM-1
The device for monitoring the loading of mills UKZM-1
The device for monitoring the loading of raw materials and cement mills UKZM-1 is designed to monitor and indicate the degree of loading of raw materials and cement ball mills by an indirect signal associated with the state of the clinker or raw charge grinding process.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Installations for verification of gamma radiation dosimeters portable UPGDS-3D
Installations for verification of gamma radiation dosimeters portable UPGDS-3D
Appointment: for transmitting units: the kerma power in the air of gamma radiation (MC); the ambient dose equivalent of gamma radiation (MAED); the power of the directional equivalent of the dose of gamma radiation (MNED); the exposure dose of gamma radiation (MED); the absorbed dose in the air of gamma radiation (MPD); it is used for verification and calibration of dosimetric measuring instruments in the gamma radiation field of the Cs-137 source under normal climatic conditions; it can be used as part of mobile laboratories, portable verification posts at enterprises.
Doza
Zelenograd
Produced in: Moscow
Portable Electrical Laboratory for Cable Damage Detection by Acoustic and Induction method Athlete KAI-1.501
Portable Electrical Laboratory for Cable Damage Detection by Acoustic and Induction method Athlete KAI-1.501
Appointment Athlete KAI-1.501 • Search for a live cable. • Detection of the passage of hidden communications (metal pipelines, cable lines). • Preliminary detection of the distance to the place of damage. • Search for places of cable damage in an acoustic way. • Search for places of cable damage by electromagnetic means. • The presence of a "Friend-Foe" mode.
Produced in: Kolomna, Moscow region
DC power supply B5-79/1
DC power supply B5-79/1
The source is capable of operating both independently and as part of automated measuring systems with interfaces such as RS-232 and ETHERNET Technical specifications Output voltage setting range from 0 to 60 V Output current setting range from 0.2 to 10 A Electrical output power, not less than 300 W The main error of the output voltage setting is ± 100 mV The main error of the output current setting is ± 100 mA Additional error in setting the output voltage caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0001 · Uust + 1 mV) Additional error in setting the output voltage caused by a change in the load current from 0.9 of the maximum value to zero ± (0.0002 · Uust + 5 mV) Additional error in setting the output current caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0002 · Iust + 2 mA) Additional error in setting the output current caused by a change in the load voltage from 0.9 of the maximum value to zero ± (0.0005 · Iust + 5 mA) Instability of the output voltage for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mV Instability of the output current for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mA Operating temperature range from 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 500 VA Overall dimensions, mm 240x128x313 Weight, not more than 6.0 kg
Produced in: Moscow
Rubidium reference generator RRS-002
Rubidium reference generator RRS-002
The device is made in a 19-inch rack design with a 4U stand. The rubidium reference generator RRS-002 provides up to 15 independent signal outputs with a frequency of 10 MHz (5 MHz). The device is designed for long-term uninterrupted operation both in round-the-clock continuous and in session mode. The high reliability of the generator is ensured by reserving the main generator blocks and, in case of malfunction of the active signal source, automatically switching to a backup one.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
HUMAN RADIATION SPECTROMETER SKG‑AT1316
HUMAN RADIATION SPECTROMETER SKG‑AT1316
Calculation of the expected effective dose of internal radiation per year from incorporated 137Cs and 134Cs Flexible software control of the spectrometer functions, the formation of a database and a report on the results of the survey Express control capacity - 15 people per hour The possibility of sharing AT1316(AT1316A) and AT1322(AT1322/1) The possibility of accommodation in a minibus as part of a mobile radiation control laboratory
Produced in: Belarus, Minsk
Vibrometer VVM-311
Vibrometer VVM-311
A portable vibrometer with a digital indicator is designed to measure the main vibration parameters (vibration acceleration, vibration velocity, vibration displacement) of operating equipment, machines and other objects in laboratory and industrial conditions.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Individual thermoluminescent dosimeters
Individual thermoluminescent dosimeters
The principle of operation of dosimeters is based on the accumulation of ionizing radiation energy by detectors proportional to the radiation dose. In DVG-02TM installations, DOZA-TLD complexes, etc., when the detector is heated, the accumulated energy is released in the form of light radiation, which is recorded by an electronic device.
Doza
Zelenograd
Produced in: Moscow
High-temperature smart surface  probe  L=300 mm SZPVV.300
High-temperature smart surface probe L=300 mm SZPVV.300
from 12 960 ₽
The high-temperature smart surface probe L=300 mm SZPVV.300 is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPVV.300 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPVV smart probe.300 Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Dosimeter-radiometer household ISS-05 "Terra-P"
Dosimeter-radiometer household ISS-05 "Terra-P"
Purpose measurement of the ambient dose equivalent of N*(10) gamma radiation; measurement of ambient dose equivalent of H*(10) gamma radiation; assessment of surface contamination with radionuclides.
Doza
Zelenograd
Produced in: Moscow